To evaluate the diagnostic efficiency of the neural network in predicting complications of Small Incision Lenticule Extraction in a multi-center cross-sectional study.
The primary cause of global visual impairment currently is refractive error, and Small Incision Lenticule Extraction (SMILE) using femtosecond laser for corneal stromal lenticule extraction can alter the refractive power. However, complications such as opaque bubble layer (OBL), negative pressure detachment, and black spots may arise during the SMILE laser scanning process due to individual differences in corneal characteristics, significantly affecting the normal course of surgery and postoperative recovery. Experienced docters can often predict intraoperative complications based on scan images, patient cooperation, and other factors, but the learning curve is relatively long. At present, artificial intelligence has achieved the accuracy comparable to human physicians in the interpretation of medical imaging of many different diseases.Previously, we have trained a deep convolutional neural network for predicting intraoperative complications in SMILE procedures. The current multi-center study is designed to evaluate the efficacy of the convolutional neural network based algorithm in predicting intraoperative complications and to assess its utility in the real world.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Eyes with SMILE surgeries | Eyes with SMILE surgeries which were performed by surgeons with experiences. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| AI diagnostic algorithm | Diagnostic Test | The SMILE procedures collected would be assessed by the algorithm. The performance of the algorithm would be assessed, including accuracy, AUC, sensitivity and specificity. |
| Measure | Description | Time Frame |
|---|---|---|
| AUROC of convolutional neural network in predicting OBL area | The area under the receiver operating characteristic of convolutional neural network in predicting opaque bubble layer area during the SMILE surgeries | Day 0 |
| AUROC of convolutional neural network in predicting progressive suction loss | The area under the receiver operating characteristic of convolutional neural network in predicting progressive suction loss during the SMILE surgeries | Day 0 |
| AUROC of convolutional neural network in predicting effective optical zone | The area under the receiver operating characteristic of convolutional neural network in predicting effective optical zone after the SMILE surgeries | Day 7 |
| AUROC of convolutional neural network in predicting postoperative refractive error | The area under the receiver operating characteristic of convolutional neural network in predicting refractive error after the SMILE surgeries | Day 7 |
| AUROC of convolutional neural network in predicting postoperative central corneal thickness | The area under the receiver operating characteristic of convolutional neural network in predicting central corneal thickness after the SMILE surgeries | Day 7 |
| Measure | Description | Time Frame |
|---|---|---|
| Sensitivity and specificity of convolutional neural network in predicting OBL area | Sensitivity and specificity of convolutional neural network in predicting opaque bubble layer area during the SMILE surgeries | Day 0 |
| Sensitivity and specificity of convolutional neural network in predicting progressive suction loss |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Patients from clinics in different eye centers across China. Each subject must with complete surgical video recording and medical records.
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Jian Xiong, docter | Contact | 18170906556 | +86 | 894040417@qq.com |
| Fu Gui, docter | Contact | 13879101919 | +86 | 564436578@qq.com |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| The Second Affiliated Hospital of Nanchang University | Recruiting | Nanchang | Jiangxi | 330000 | China |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Sensitivity and specificity of convolutional neural network in predicting progressive suction loss during the SMILE surgeries |
| Day 0 |
| Sensitivity and specificity of convolutional neural network in predicting effective optical zone | ensitivity and specificity of convolutional neural network in predicting effective optical zone after the SMILE surgeries | Day 7, Day 30, Day 90 |
| ID | Term |
|---|---|
| D012904 | Smiling |
| D007431 | Intraoperative Complications |
| ID | Term |
|---|---|
| D005149 | Facial Expression |
| D009633 | Nonverbal Communication |
| D003142 | Communication |
| D001519 | Behavior |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided