Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| University of Zagreb | OTHER |
| University of Rijeka | OTHER |
Not provided
Not provided
Not provided
Not provided
Objective is to assess changes of dentition and periodontium, and hygiene in retention after the end of the active phase of orthodontic treatment, and relationship with gender, type of retention appliance, pre-therapeutic condition of dentition and duration of active phase of treatment.
A total of 152 subjects will be recruited and randomly assigned into three groups. First group will have a square 8-stranded 0.673x0.268 mm retainer wire bonded in mandibular teeth after completing the active phase of comprehensive orthodontic treatment with fixed appliances. Retainer will be bonded on lingual site canine to canine on each tooth. Second group will have a round 6-stranded 0.40 mm retainer in mandible. Third group will be without fixed retainer, only with thermoplastic vacuum-formed removable Essix retainer in mandible.
Subjects will be examined before orthodontic treatment (T0), upon completion of treatment (T1), six months in retention (T2), two years (T3) and three years in retention (T4). Changes in intercanine width, relapse (unexpected tooth movements), retainer failure, accumulation of biofilm, calculus and gingivitis will be assessed.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| fixed mandibular lingual rectangular retainer 0.673 x 0.268 mm | Experimental | 0.673 x 0.268 mm 8-stranded wire Bond A Braid (Reliance Orthodontic Products, USA) will be bonded in mandible canine to canine on each tooth using Filtek flowable composite (Ivoclar Vivadent, Lichtenstein) and Multilink adhesive (3M, USA). |
|
| fixed mandibular lingual round retainer 0.40 mm | Experimental | 0.40 mm round 6-stranded wire (Forestadent, Germany) will be bonded on 6 mandibular frontal teeth, canine to canine on each tooth using Filtek flowable composite (Ivoclar Vivadent, Lichtenstein) and Multilink adhesive (3M, USA). |
|
| removable mandibular retainer | Active Comparator | Group without fixed retainer will be wearing removable thermoplastic vacuum-formed Essix retainer |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| fixed retainer | Device | bonded lingual mandibular fixed retainer on frontal teeth 33-43 |
|
| Measure | Description | Time Frame |
|---|---|---|
| severity of relapse (unexpected tooth movement in mandibular frontal area) at 1 year | the unabbreviated scale title: Little Irregularity Index (used to measure the crowding)- numerical rating scale in millimeters the minimum and maximum values: 0,10 higher scores mean a worse outcome lower scores mean a better outcome | 1 year |
| severity of relapse (unexpected tooth movement in mandibular frontal area) at 2 years | the unabbreviated scale title: Little Irregularity Index (used to measure the crowding)- numerical rating scale in millimeters the minimum and maximum values: 0,10 higher scores mean a worse outcome lower scores mean a better outcome | 2 years |
| severity of relapse (unexpected tooth movement in mandibular frontal area) at 3 years | the unabbreviated scale title: Little Irregularity Index (used to measure the crowding)- numerical rating scale in millimeters the minimum and maximum values: 0,10 higher scores mean a worse outcome lower scores mean a better outcome | 3 years |
| incidence of retainer failure (debonding, breakage) at 2 years | percentage of cases with at least one fixed retainer failure, the minimum and maximum values 0%,100% higher scores mean a worse outcome, lower scores mean a better result | 2 years |
| incidence of retainer failure (debonding, breakage) at 3 years | percentage of cases with at least one fixed retainer failure, the minimum and maximum values 0%,100% higher scores mean a worse outcome, lower scores mean a better result | 3 years |
| extent of biofilm accumulation at 2 years |
| Measure | Description | Time Frame |
|---|---|---|
| incidence of intercanine width change | percentage of cases with intercanine width change, the minimum and maximum values 0%,100% higher scores mean a worse outcome, lower scores mean a better result | 3 years |
| changes of intercanine width |
| Measure | Description | Time Frame |
|---|---|---|
| incidence of relapse at 2 years | the unabbreviated scale title: percentage of relapsed cases; the minimum and maximum values 0%,100%, higher scores mean a worse outcome, lower scores mean a better outcome | 2 years |
| incidence of relapse at 3 years |
Inclusion Criteria: finished orthodontic treatment, participants must have all permanent teeth Exclusion Criteria: hypodontia, missing teeth
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Silvija Kanižaj Ugrin, DDM | Contact | 00385915232860 | kanizaj.ugrin@gmail.com | |
| Stjepan Špalj, PhD | Contact | 00385916119853 | stjepan.spalj@fdmri.uniri.hr |
| Name | Affiliation | Role |
|---|---|---|
| Silvija Kanižaj Ugrin, DDM | Poliklinika Orthonova | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Poliklinika Orthonova | Recruiting | Zagreb | 10000 | Croatia |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 41239352 | Derived | Kanizaj Ugrin S, Kiseri Kubati J, Cirgic E, Simeon P, Spalj S. Stability, survival and costs of vacuum-formed retainers versus bonded lingual braided rectangular and multistranded round wire retainers in the mandible of orthodontic patients over a two-year period. BMC Oral Health. 2025 Nov 14;25(1):1782. doi: 10.1186/s12903-025-07174-w. | |
| 38424224 |
Not provided
Not provided
on request
Not provided
Not provided
Not provided
Not provided
| Type | Date | Date Unknown |
|---|---|---|
| Release | Nov 18, 2023 | |
| Reset | May 8, 2024 |
Not provided
Not provided
| Release Date | Unrelease Date | Unrelease Date Unknown | Reset Date | MCP Release Number |
|---|---|---|---|---|
| Nov 18, 2023 | May 8, 2024 |
| ID | Term |
|---|---|
| D000077744 | Orthodontic Appliances, Fixed |
| ID | Term |
|---|---|
| D009967 | Orthodontic Appliances |
| D009970 | Orthodontics |
| D003813 | Dentistry |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| removable retainer | Device | thermoplastic vacuum-formed removable mandibular retainer |
|
the unabbreviated scale title: Silness and Loe Plaque Index-ratio of measuring sites in mandibular central sextant; the minimum and maximum values 0%,100%, higher scores mean a worse outcome, lower scores mean a better result
| 2 years |
| extent of biofilm accumulation at 3 years | the unabbreviated scale title: Silness and Loe Plaque Index-ratio of measuring sites in mandibular central sextant; the minimum and maximum values 0%,100%, higher scores mean a worse outcome, lower scores mean a better result | 3 years |
the unabbreviated scale title: intercanine width change in millimeters, the minimum and maximum values 0,5, higher scores mean a worse outcome, lower result mean a better outcome
| 2 years, 3 years |
| extent of calculus accumulation at 2 years | the unabbreviated scale title: Calculus Surface Index (CSI)-ratio of measuring sites in mandibular central sextant; the minimum and maximum values 0%,100%, higher scores mean a worse outcome, lower scores mean a better outcome | 2 years |
| extent of calculus accumulation at 3 years | the unabbreviated scale title: Calculus Surface Index (CSI)-ratio of measuring sites in mandibular central sextant; the minimum and maximum values 0%,100%, higher scores mean a worse outcome, lower scores mean a better outcome | 3 years |
the unabbreviated scale title: percentage of relapsed cases; the minimum and maximum values 0%,100%, higher scores mean a worse outcome, lower scores mean a better outcome
| 3 years |
| extent of gingivitis at 2 years | the unabbreviated scale title: Bleeding on probing (BOP)-ratio of measuring sites in mandibular central sextant; the minimum and maximum values 0%,100%, higher scores mean a worse outcome, lower scores mean a better result | 2 years |
| extent of gingivitis at 3 years | the unabbreviated scale title: Bleeding on probing (BOP)-ratio of measuring sites in mandibular central sextant; the minimum and maximum values 0%,100%, higher scores mean a worse outcome, lower scores mean a better result | 3 years |
| duration of orthodontic treatment in months | the unabbreviated scale title: numerical rating scale the minimum and maximum values: 0,30 | 1 year |
| satisfaction with stability of results in retention period | Participant's satisfaction with stability of results as assessed using a 5-point Likert scale. Scores range from "very unsatisfied" (1) to "very satisfied" (5). Higher scores mean a better outcome, lower scores mean a worse outcome | 3 years |
| costs total | calculation of costs of retention: failures and new retainers in euros | 3 years |
| loss of productivity | the unabbreviated scale title: number of check-ups in retention period; the minimum and maximum values 0,10; higher scores mean a worse outcome, lower scores mean a better result the minimum and maximum values: 0,30 | 3 years |
| Kanizaj Ugrin S, Spalj S. Comparison of efficacy of thermoplastic retainer with round and rectangular bonded lingual wire retainer in the mandible two years after orthodontic treatment: a randomised controlled trial. Clin Oral Investig. 2024 Mar 1;28(3):183. doi: 10.1007/s00784-024-05572-y. |