The importance of this trial lies in testing if intraoral digital impressions will increase the accuracy of impressions of full arch implant cases over conventional impression techniques thus improving the passivity of full arch screw retained prosthesis and decreasing the prosthetic complications in turn.
In this study intraoral digital impressions will be used for scanning full arch implant cases to minimize the variables in the conventional technique, finally the study will investigate if the intraoral digital impressions will increase the accuracy of impressions of full arch implant cases thus improving the passivity and decreasing prosthetic complications of screw retained prosthesis for a long-term success compared to open tray impression technique.
Primary outcome will be evaluation of the passivity of PMMA (Polymethyl methacrylate ) try-in , while secondary outcomes will be detecting prosthetic complications (screw loosening , prosthesis fracture) and treatment time for both groups.
Eligibility criteria:
Inclusion criteria:
Exclusion criteria:
Interventions:
Completely edentulous patients that have received dental implants and ready to start prosthetic steps of full arch screw retained prosthesis will be recruited and randomly divided into two groups.
Group 1 ( control group):
while in Group 2 ( intervention group):
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Digital impression technique | Other | - 3D printed generic Scan bodies with unified shape and length replacing the traditional transfer copings will be press fitted on the trans-mucosal abutments and pickup cylinders that are screwed on the implants to capture their position and intra-oral scanning will be done. |
|
| Open tray impression technique | Other |
|
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Digital impression technique | Device | 3D printed generic Scan bodies with unified shape and length replacing the traditional transfer copings will be press fitted on the trans-mucosal abutments and pickup cylinders that are screwed on the implants to capture their position and intra-oral scanning will be done. |
| Measure | Description | Time Frame |
|---|---|---|
| Passivity of seating of PolyMethylMethAcrylate (PMMA) tryin prosthesis | the screw retained prosthesis can be considered passive when it does not generate static loads and strains within the prosthesis or in the surrounding bone structure measured using Single screw test (measuring unit : binary - yes/No) | 3-4 months after implants placement after final impressions for implants |
| Passivity of seating of PolyMethylMethAcrylate (PMMA) tryin prosthesis | the screw retained prosthesis can be considered passive when it does not generate static loads and strains within the prosthesis or in the surrounding bone structure measured using -Periapical radiograph ( measuring unit : binary- Yes/No) | 3-4 months after implants placement after final impressions for implants |
| Passivity of seating of PolyMethylMethAcrylate (PMMA) tryin prosthesis | the screw retained prosthesis can be considered passive when it does not generate static loads and strains within the prosthesis or in the surrounding bone structure measured using - Screw resistance parameter (Measuring unit: Difference of rotation angles in passive and non- passive situations) | 3-4 months after implants placement after final impressions for implants |
| Measure | Description | Time Frame |
|---|---|---|
| Prosthetic complications including screw loosening and prosthesis fracture | screw loosening , prosthesis fracture will be assessed by clinical examination (measuring unit : number of times ) | At 3, 6 months after delivery of final prosthesis |
| Treatment time |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Completely edentulous patients with sufficient inter-arch space to receive fixed prosthesis (Crown height space 9-15 mm per arch)
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Open tray impression technique | Other | Transfer copings will be screwed to the multiunit abutments on the existing implants, and splinted together using pre-cured printed resin splinting framework that will be fixed to the copings using flowable composite . A one step impression technique using putty and light addition silicon will be made, where light impression material will be injected all around transfer copings and putty silicon will be loaded in tray and then will be seated intra-orally making sure to fully expose the screws of transfer copings through the impression material. |
|
Number of visits |
| 5-6 months after implants placement ( at the last visit ) |