It's crucial to determine whether a pulse is present or not in patient with cardiac arrest. But more and more studies have shown that manual palpation is unreliable for detecting pulse 1-4. Failure to detect pulselessness may cause delay of chest compression and directly affect the patient's outcome. Likewise, failure to rapidly detect return of spontaneous circulation may cause prolonged chest compression and increase associated injury during resuscitation.
More and more studies have demonstrated that echo guided pulse detection is feasible 5-7. The aim of our study is to check carotid pulse via ultrasound. This is a prospective study and the patient selection is in-hospital or out of hospital cardiac arrest. A curvilinear ultrasonography transducer is used and placed transversely on either right/left carotid artery under pulsed-wave doppler mode to check whether the pulse is present or not. The result of ultrasonography will be compared with manual palpation and to determine the accuracy and effectiveness of clinical usage.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Patient presenting at emergent department with cardiac arrest |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Carotid ultrasound under pulsed-wave doppler mode | Device | Carotid ultrasound under pulsed-wave doppler mode to check whether carotid pulse is present |
|
| Measure | Description | Time Frame |
|---|---|---|
| Carotid ultrasound under pulsed-wave doppler compared with manual palpation | The result of ultrasonography will be compared with manual palpation and to determine the accuracy(e.g., no pulse under manual palpation but positive pulse-wave finding)of clinical usage. | 5 seconds during pulse check period of resuscitation |
| Carotid ultrasound under pulsed-wave doppler compared with manual palpation | The result of ultrasonography will be compared with manual palpation and to determine the effectiveness (e.g., the time need to confirm whether pulse is present or not under manual palpation and ultrasound) of clinical usage. | 5 seconds during pulse check period of resuscitation |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
any patient presenting at ER with cardiac arrest older than 20 years-old, including trauma or non-trauma cardiac arrest, in-hospital or out-of-hospital cardiac arrest
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| National Taiwan University Hospital | Taipei | 100 | Taiwan |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 9259056 | Result | Bahr J, Klingler H, Panzer W, Rode H, Kettler D. Skills of lay people in checking the carotid pulse. Resuscitation. 1997 Aug;35(1):23-6. doi: 10.1016/s0300-9572(96)01092-1. | |
| 9025126 | Result | Eberle B, Dick WF, Schneider T, Wisser G, Doetsch S, Tzanova I. Checking the carotid pulse check: diagnostic accuracy of first responders in patients with and without a pulse. Resuscitation. 1996 Dec;33(2):107-16. doi: 10.1016/s0300-9572(96)01016-7. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D006323 | Heart Arrest |
| ID | Term |
|---|---|
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
| 10825620 | Result | Moule P. Checking the carotid pulse: diagnostic accuracy in students of the healthcare professions. Resuscitation. 2000 May;44(3):195-201. doi: 10.1016/s0300-9572(00)00139-8. |
| 10524730 | Result | Liberman M, Lavoie A, Mulder D, Sampalis J. Cardiopulmonary resuscitation: errors made by pre-hospital emergency medical personnel. Resuscitation. 1999 Sep;42(1):47-55. doi: 10.1016/s0300-9572(99)00082-9. |
| 30902687 | Result | Badra K, Coutin A, Simard R, Pinto R, Lee JS, Chenkin J. The POCUS pulse check: A randomized controlled crossover study comparing pulse detection by palpation versus by point-of-care ultrasound. Resuscitation. 2019 Jun;139:17-23. doi: 10.1016/j.resuscitation.2019.03.009. Epub 2019 Mar 20. |
| 31003817 | Result | Simard RD, Unger AG, Betz M, Wu A, Chenkin J. The POCUS Pulse Check: A Case Series on a Novel Method for Determining the Presence of a Pulse Using Point-of-Care Ultrasound. J Emerg Med. 2019 Jun;56(6):674-679. doi: 10.1016/j.jemermed.2019.02.013. Epub 2019 Apr 16. |
| 30013612 | Result | Germanoska B, Coady M, Ng S, Fermanis G, Miller M. The reliability of carotid ultrasound in determining the return of pulsatile flow: A pilot study. Ultrasound. 2018 May;26(2):118-126. doi: 10.1177/1742271X17753467. Epub 2018 Jan 29. |