The current cardiopulmonary resuscitation(CPR) guidelines recommend that the heart rhythm be checked every two minutes during CPR for cardiac arrest patients. Also it is very important to stop compressing the chest in less than 10 seconds when checking heart rhythm and pulse.
However, manual palpation, which is used as a standard for return of spontaneous circulation(ROSC), has been reported that the accuracy is not high in several studies. It is quite often necessary to perform pulse palpation for longer than the 10 second recommended by the guidelines to make a judgment.
Recently, a case study was published in which the presence of spontaneous circulation was confirmed by evaluating the carotid artery compressibility and pulsatility with an ultrasound probe when checking the rhythm of cardiac arrest patients. However, there has been no clinical study on actual cardiac arrest patients.
The current cardiopulmonary resuscitation(CPR) guidelines recommend that the heart rhythm be checked every two minutes during CPR for cardiac arrest patients. Also it is very important to stop compressing the chest in less than 10 seconds when checking heart rhythm and pulse.
However, manual palpation, which is used as a standard for return of spontaneous circulation(ROSC), has been reported that the accuracy is not high in several studies. It is quite often necessary to perform pulse palpation for longer than the 10 second recommended by the guidelines to make a judgment.
Ultrasound is a key technique that guides to discern and treat causes of cardiac arrest patients. Recently, a case study was published in which the presence of spontaneous circulation was confirmed by evaluating the carotid artery compressibility and pulsatility with an ultrasound probe when checking the rhythm of cardiac arrest patients.
However, this is just a case study. There has been no clinical study on actual cardiac arrest patients whether it is possible to accurately determine the ROSC by evaluating the carotid artery compressibility and pulsatility by ultrasound. Also there has been no clinical studies on actual cardiac arrest patients comparing the time taken to evaluate the ROSC of carotid ultrasound and manual palpation.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Carotid ultrasound | Experimental | When stopping chest compressions to check manual palpation every 2 minutes, an ultrasound scan of the carotid artery is performed. Whether or not return of spontaneous circulation is determined based on the compressibility and pulsatility of the carotid artery, and the time taken from the start of the ultrasound scan to the determination is recorded. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| carotid ultrasound | Diagnostic Test | Every time checking pulse, evaluate the carotid artery compressibility and pulsatility by ultrasound |
|
| Measure | Description | Time Frame |
|---|---|---|
| Time spent assessing | Time spent assessing return of spontaneous circulation using two methods (manual pulse palpation and carotid ultrasound) | Procedure (during chest compression) |
| Measure | Description | Time Frame |
|---|---|---|
| Agreement of return of spontaneous circulation | Compare the agreement between two methods (manual pulse palpation and carotid ultrasound) for evaluation of return of spontaneous circulation (ROSC). The gold standard is arterial blood pressure by arterial catheter. The ROSC is judged when pulsation is detected by manual palpation. The ROSC is judged when carotid artery is not totally compressed or has pulsatility by carotid artery ultrasound. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Sooyeon Kang, Fellow | Contact | +821031574718 | syrei3.kang@samsung.com |
| Name | Affiliation | Role |
|---|---|---|
| Hee Yoon, Professor | Samsung medical center, Emergency department | Study Chair |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Samsung Medical Center | Recruiting | Seoul | 06351 | South Korea |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D006323 | Heart Arrest |
| ID | Term |
|---|---|
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D000092262 | Ultrasonography, Carotid Arteries |
| ID | Term |
|---|---|
| D014463 | Ultrasonography |
| D003952 | Diagnostic Imaging |
| D019937 | Diagnostic Techniques and Procedures |
| D003933 | Diagnosis |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Procedure (during chest compression) |