The FloPatch FP120 device is indicated for use for the noninvasive assessment of blood flow in the carotid artery. The FloPatch FP120 device uses ultrasound and the Doppler effect to non-invasively assess the flow of flood. In this study, the FloPatch FP120 will be applied to the neck at the location of the carotid artery on cardiac arrest patients in the emergency department. FloPatch FP120 data will be compared with arterial line blood pressure to assess for accuracy of pulse checks among cardiac arrest patients in the emergency department.
The FloPatch FP120 device is indicated for use for the noninvasive assessment of blood flow in the carotid artery. The FloPatch FP120 device uses ultrasound and the Doppler effect to non-invasively assess the flow of flood. In this study, the FloPatch FP120 will be applied to the neck at the location of the carotid artery on cardiac arrest patients in the emergency department. This study will determine the peak systolic velocity, as measured by the FLoPatch FP120 device, that is associated with a systolic blood pressure of ≥60 mmHg on a femoral arterial line in cardiac arrest patients during a pulse check. The associated accuracy, sensitivity, and specificity of the calculated pulse systolic velocity to detect return of spontaneous circulation with a systolic blood pressure ≥60 mmHg in cardiac arrest.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Patients achieving return of spontaneous circulation | All patients in cardiac arrest with an arterial line in place in the emergency department will be a potential subject. The FloPatch FP120 device will be placed on patients and the carotid artery peak systolic velocity associated with a systolic blood pressure ≥60 mmHg on a femoral arterial line during a pulse check will be determined. |
| |
| Patients not achieving return of spontaneous circulation | All patients in cardiac arrest with an arterial line in place in the emergency department will be a potential subject. The FloPatch FP120 device will be placed on patients and the carotid artery peak systolic velocity associated with a systolic blood pressure ≥60 mmHg on a femoral arterial line during a pulse check will be determined. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| FloPatch FP120 | Device | FloPatch FP120 is an FDA 510(k) cleared device indicated for the non-invasive assessment of blood flow in the carotid artery by medical professionals, such as physicians and nurses. FloPatch uses ultrasound and the Doppler effect to assess blood flow. |
| Measure | Description | Time Frame |
|---|---|---|
| Number of Patients with Return of Spontaneous Circulation | Any patient achieving any episode of return of spontaneous circulation during a pulse check will be considered as having the outcome. Cardiac arrest resuscitations are typically not longer than 30 minutes. | 30 minutes |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Patients 18+ years of age in atraumatic cardiac arrest with an arterial line placed in the emergency department during resuscitation.
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Timmy Li, PhD | Contact | 516-240-3933 | tli2@northwell.edu |
| Name | Affiliation | Role |
|---|---|---|
| Allison Cohen, MD | North Shore University Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| North Shore University Hospital | Recruiting | Manhasset | New York | 11030 | United States |