Comparison of manometry measurements and EndoFlip Balloon measurements in patients with dysphagia and a known esophageal diagnosis
Gastrointestinal (GI) motility problems are very common in the general population. Dysphagia, difficulty swallowing, is one of the most common issues in gastroenterology. In many patients, esophageal obstruction is not identified despite workup with upper endoscopy or barium swallow x-ray. Patients are often referred to the Motility Laboratory for evaluation of non-obstructive dysphagia. Transnasal esophageal manometry-impedance is a diagnostic test to measure the pressures and coordination of the esophagus during swallowing. The Endolumenal Functional Lumen Imaging Probe (EndoFLIP) is another instrument used to measure the lumen distensibility of the esophagus and pylorus. Both tests are FDA-approved and are currently being used in clinical practice. However, correlation of the results obtained from these tests with clinical syndromes and symptoms is not clearly understood. Furthermore, the relationship between esophageal impedance-manometry and EndoFLIP results has never been defined.
The primary Aim is to develop a registry of patients undergoing esophageal manometry-impedance and Endoflip from the GI Motility Lab at the IU University Hospital
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Dysphagia | Patients with Esophageal dysphagia |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Manometry | Diagnostic Test | Transnasal Esophageal manometry and Endoflip Balloon distensibility |
|
| Measure | Description | Time Frame |
|---|---|---|
| Endoflip parameters for gastroparesis | Compare the distensibility index (mm2/mmHg) of the pylorus at 50 ml distension in patients with postsurgical gastroparesis and compare to patients with idiopathic and diabetic gastroparesis. | 5 years |
| Measure | Description | Time Frame |
|---|---|---|
| Correlation between endoflip parameters and gastric scintigraphy | Correlate distensibility data (cross-sectional area, pressure, distensibility index) with severity of delayed gastric emptying in patients with gastroparesis | 5 years |
| Correlation between endoflip parameters and symptom severity |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Study subjects will be recruited from patients who were referred by their physicians to the GI Motility Lab at IU University Hospital for esophageal manometry-impedance and/or EndoFLIP
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Lainna Cohen | Contact | larcohen@iu.edu | ||
| Maureen Schilling | Contact | maschi@iu.edu |
| Name | Affiliation | Role |
|---|---|---|
| John M Wo, MD | Indiana University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Indiana University Health University Hospital | Recruiting | Indianapolis | Indiana | 46202 | United States |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003680 | Deglutition Disorders |
| ID | Term |
|---|---|
| D004935 | Esophageal Diseases |
| D005767 | Gastrointestinal Diseases |
| D004066 | Digestive System Diseases |
| D010608 | Pharyngeal Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Correlate distensibility data (cross-sectional area, pressure, distensibility index) with severity of gastroparesis symptoms by Patient Assessment GI-Ssymptoms (PAGI-SYM) |
| 5 years |
| D010038 | Otorhinolaryngologic Diseases |