Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Semmelweis University Heart and Vascular Center | OTHER |
Not provided
Not provided
Not provided
Not provided
Digital Variance Angiography (DVA) is a new tool in medical imaging with proven image quality reserve.
The previously observed quality reserve of Digital Variance Angiography (DVA) in lower extremity angiographies, allowed to lower radiation exposure by 70 % during DSA in lower extremity diagnostic angiographies with non-inferior image quality.
The aim of this study is to apply this non-inferior image quality and use it for radiation exposure reduction in diagnostic lower limb angiography.
The project would prospectively block-randomise (50:50) patients, who undergo elective diagnostic angiography into two groups: a comparator group examined by means of conventional DSA using a standard care protocol (Siemens Artis Zee, Extremities Care setting, 1.2 µGy/frame) (Group B) and a study group examined by means of DVA using a low-dose protocol (0.36 µGy/frame corresponding to 70% decrease of radiation dose) (Group A). During each procedure the investigators record radiation exposure (cumulative dosage, dose area product) and contrast media usage and procedural time then compare the results of the groups. Qualitative image review is done to compare conventional DSA and reduced radiation exposure DVA images after image acquisition.
Our hypothesis is that with the previously proven non-inferior image quality, the investigators will be able to reduce radiation exposure of the participants and also staff members in everyday clinical practice.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Group A: Low-dose DVA group | Experimental | Image acquisition at a reduced X-ray dose, 0.36 µGy/frame (70% reduction) image processing by DVA |
|
| Group B: Normal-dose DSA group | Active Comparator | Image acquisition at a normal dose (1.2 µGy/frame) image processing by DSA |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Diagnostic Angiography (DSA or DVA based on randomization result) | Radiation | After radial/brachial/femoral artery puncture using Seldinger technique, the investigators first position a pigtail catheter above the level of the renal arteries. With Siemens Artis Zee Pure DSA machine the examiner will use a postero-anterior X-ray view for the first image, which is an aortography of some part of the iliac system. Then, the catheter will be repositioned to the aortic bifurcation and 15-18 mL contrast media (CM) with 9-10 mL/s flow for the ilio-femoral region will be injected. All of the following image series will be made from this catheter position, with a 9 mL/s flow rate. In cases for when the recorded image series will be inconclusive, image series with left/right oblique position will be recorded. All femoro-popliteal images will be recorded with 10-16 ml CM and crural regions with 12-22mml. DSA images will be calculated from all series on a dedicated Syngo workstation and used for diagnosis. DVA images will be calculated by the Kinepict Medical Imaging Tool |
| Measure | Description | Time Frame |
|---|---|---|
| Total procedural Dose-area product(DAP) | Indicator of a patient's irradiation dosage (microGy*cm2 or Gy*cm2) | During the procedure |
| Total DSA-related DAP | Radiation load of the patient during DSA image acquistion (microGy*cm2 or Gy*cm2) | During the procedure |
| Image quality review | Blinded, anonymised and randomised qualitative review and comparison of images by multiple endovascular specialists in multiple regions using a 1-5 Likert-scale for each image. Region specific scores are compared between DSA and DVA technique. | Upon completion of enrollment, approximately 1-year period |
| TASC classification | Blinded, anonymised and randomised review of images by multiple endovascular specialists. Clinically relevant sides for each patient are reviewed in a separate questionnaire: each reviewer have to classify each patient's angiographic image according to the Trans-Atlantic Inter-Society Consensus Document's second version. | Upon completion of enrollment, approximately 1-year period |
| Measure | Description | Time Frame |
|---|---|---|
| Contrast media usage | The volume of the iodinated contrast agent used for enhancing the image quality (mL) | During the procedure |
| Number of protocol change | The number of occasions when the reduced radiation level protocol has to be switched back to conventional protocol in one region because of unsuitable image quality. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Krisztián Szigeti, Ph.D. | Kinepict Health Ltd. | Study Chair |
| Szabolcs Osváth, Ph.D. | Kinepict Health Ltd. | Study Chair |
| János Kiss, M.D.,Ph.D.,D.Sc. | Kinepict Health Ltd. | Study Chair |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Semmelweis University, Heart and Vascular Center | Budapest | 1122 | Hungary |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 30829769 | Background | Orias VI, Gyano M, Gog I, Szollosi D, Veres DS, Nagy Z, Csobay-Novak C, Zoltan O, Kiss JP, Osvath S, Szigeti K, Zoltan R, Sotonyi P. Digital Variance Angiography as a Paradigm Shift in Carbon Dioxide Angiography. Invest Radiol. 2019 Jul;54(7):428-436. doi: 10.1097/RLI.0000000000000555. | |
| 30325284 | Background |
| Label | URL |
|---|---|
| Homepage for the Kinepict scientific group, source for additional information about digital variance angiography | View source |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
All enrolled participants will undergo a diagnostic lower limb angiography, but the image acquisition protocol will be different. In the active comparator group a normal radiation dose will be used and the DSA images will be used for diagnosis whereas in the experimental group a low dose radiation will be applied (70% decrease compared tot he DSA protocol) and the DVA images will be used for diagnosis.
Not provided
Not provided
Not provided
Not provided
|
| During the procedure |
| Procedure time | Duration of the whole procedure, from radial artery puncture till the removal of every tool (min). | During the procedure |
| Gyano M, Gog I, Orias VI, Ruzsa Z, Nemes B, Csobay-Novak C, Olah Z, Nagy Z, Merkely B, Szigeti K, Osvath S, Sotonyi P. Kinetic Imaging in Lower Extremity Arteriography: Comparison to Digital Subtraction Angiography. Radiology. 2019 Jan;290(1):246-253. doi: 10.1148/radiol.2018172927. Epub 2018 Oct 16. |
| ID | Term |
|---|---|
| D058729 | Peripheral Arterial Disease |
| ID | Term |
|---|---|
| D050197 | Atherosclerosis |
| D001161 | Arteriosclerosis |
| D001157 | Arterial Occlusive Diseases |
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
| D016491 | Peripheral Vascular Diseases |
Not provided
Not provided