Digital Variance Angiography (DVA) is a new tool in medical imaging with a proven image quality reserve (1, 2).
Previous studies have demonstrated the quality reserve of DVA in angiographic studies (1, 2), which allowed us to reduce contrast media use by 50% in carotid artery angiographic studies without affecting the image quality (3).
CAS is an alternative treatment option for carotid artery revascularization in selected patient groups. Similar to most of the minimally invasive endovascular interventions, CAS also carries the risk of contrast-induced acute kidney injury, which is considered to be an independent predictor of 30-day major adverse events (4).
The aim of this study is to apply DVA in patients undergoing carotid artery stenting (CAS) and utilize this technique to reduce contrast dose during the interventions, without affecting the intraprocedural radiation dose and the clinical outcome of the procedures. Investigators believe that the reduction in contrast media use and the associated image quality with the technique of DVA imaging can be incorporated into the everyday clinical practice, and will play an important role in improving the rate of contrast-induced acute kidney injury.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Group A: Reduced contrast media dose group | Experimental | Reduced contrast media protocol: extracranial carotid artery intervention (2-4 fps according to the institutional protocol). Contrast administration with an automatic contrast injector: angiographic image acquisitions will be performed with 6 ml of 50% contrast media (3 ml iodined contrast media, 3 ml physiologic saline) with a 3 ml/s flow rate. DSA and DVA images will be calculated; DVA images will be used for diagnosis and interventions. |
|
| Group B: Standard contrast media dose group | Active Comparator | Standard contrast media protocol: extracranial carotid artery intervention (2-4 fps according to the institutional protocol). Contrast administration with an automatic contrast injector: angiographic image acquisitions will be performed with 6 ml iodined contrast media with a 3 ml/s flow rate. DSA and DVA images will be calculated; DSA images will be used for diagnosis and interventions. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Carotid artery stenting with standard contrast media protocol | Procedure | Radial, brachial or femoral arterial access is gained by using the Seldinger technique. The common carotid artery (CCA) is catheterized. Selective angiography is performed from the anteroposterior and lateral view without magnification. Initial angiograms are performed with standard contrast media protocol in anteroposterior and lateral views without magnification with the sheath placed in the common carotid artery. The carotid arterial lesion is crossed and an embolic protection device is deployed in the internal carotid artery. Carotid artery stenting is performed in a standard fashion. Post-stenting angiographies are obtained with the standard contrast media protocol in anteroposterior and lateral views without magnification with the sheath placed in the CCA. Pre- and post-stenting angiographies are performed with the same sheath position. DSA and DVA images will be calculated on a commercially available image processing workstation and the Kinepict Medical Imaging Tool. |
| Measure | Description | Time Frame |
|---|---|---|
| DSA-related contrast media use | Volume of the iodinated contrast agent used for enhancing the image quality (mL) | During the procedure |
| Total procedural contrast media use | Volume of the iodinated contrast agent used for enhancing the image quality (mL) | During the procedure |
| Image quality, graded by independent observers | Observations based on a 5-level Likert scale (1-poor image quality, 3-medium image quality, 5-outstanding image quality) | through study completion, an average of 1 year |
| Measure | Description | Time Frame |
|---|---|---|
| Total procedural dose area product | Indicator of a patient's irradiation dosage (microGy*cm2 or Gy*cm2) | During the procedure |
| DSA-related dose area product | Indicator of a patient's irradiation dosage (microGy*cm2 or Gy*cm2) |
Not provided
Inclusion Criteria:
Stenosis ≥70% by computer tomography angiography (NASCET criteria); OR by duplex-ultrasound with ≥70% stenosis defined by a peak systolic velocity of at least 230 cm/s
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Péter Sótonyi, MD, PhD | Contact | +36 20 825 8046 | sotonyi@hotmail.com | |
| Peter T Legeza, MD | Contact | +36 20 825 9736 | peterlegeza@gmail.com |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Semmelweis University, Heart and Vascular Center | Recruiting | Budapest | 1122 | Hungary |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 30325284 | Background | Gyano M, Gog I, Orias VI, Ruzsa Z, Nemes B, Csobay-Novak C, Olah Z, Nagy Z, Merkely B, Szigeti K, Osvath S, Sotonyi P. Kinetic Imaging in Lower Extremity Arteriography: Comparison to Digital Subtraction Angiography. Radiology. 2019 Jan;290(1):246-253. doi: 10.1148/radiol.2018172927. Epub 2018 Oct 16. | |
| 30829769 | Background |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Enrolled participants will undergo carotid artery stenting with different image acquisition protocol of the pre-and postinterventional angiographies from anteroposterior and lateral views, and intraoperative angiographies with C-arm angulations based on the operator's decision. In the active comparator group, a standard contrast media dose and DSA images will be used for diagnosis whereas in the experimental group a reduced contrast media dose will be applied (50% decrease compared to the standard DSA protocol) and the operator will use DVA images for the diagnosis.
Not provided
Not provided
Not provided
Not provided
|
|
| Carotid artery stenting with reduced contrast media protocol | Procedure | Radial, brachial or femoral arterial access is gained by using the Seldinger technique. The common carotid artery (CCA) is catheterized. Selective angiography is performed from the anteroposterior and lateral view without magnification. Initial angiograms are performed with the reduced contrast media protocol in anteroposterior and lateral views without magnification with the sheath placed in the common carotid artery. The carotid arterial lesion is crossed and an embolic protection device is deployed in the internal carotid artery. Carotid artery stenting is performed in a standard fashion. Post-stenting angiographies are obtained with the reduced contrast media protocol in anteroposterior and lateral views without magnification with the sheath placed in the CCA. Pre- and post-stenting angiographies are performed with the same sheath position. DSA and DVA images will be calculated on a commercially available image processing workstation and the Kinepict Medical Imaging Tool. |
|
|
| Carotid Duplex Ultrasound | Diagnostic Test | Pre- and postinterventional assessment of the treated internal carotid artery. |
|
| During the procedure |
| Total procedural time | Duration of the whole procedure, from arterial access till the removal of every tool (min) | During the procedure |
| Number of protocol changes during DVA usage | Number of occasions when the reduced contrast media protocol has to be switched back to conventional protocol because of the unsuitable image quality | During the procedure |
| Residual stenosis | The difference between the normal reference segment diameter and the minimum lumen diameter of the treated lesion after CAS (%) | During the procedure |
| Focal neurological symptoms | Focal neurological symptoms ipsilateral to the treated carotid artery during the postprocedural observation period | During the procedure and up to 1 day |
| Preoperative and postoperative ipsilateral carotid artery flow by doppler ultrasound | Peak-systolic and end-diastolic velocities (cm/sec) | Preoperatively and 1 day after the procedure |
| Orias VI, Gyano M, Gog I, Szollosi D, Veres DS, Nagy Z, Csobay-Novak C, Zoltan O, Kiss JP, Osvath S, Szigeti K, Zoltan R, Sotonyi P. Digital Variance Angiography as a Paradigm Shift in Carbon Dioxide Angiography. Invest Radiol. 2019 Jul;54(7):428-436. doi: 10.1097/RLI.0000000000000555. |
| 33294499 | Background | Orias VI, Szollosi D, Gyano M, Veres DS, Nardai S, Csobay-Novak C, Nemes B, Kiss JP, Szigeti K, Osvath S, Sotonyi P, Ruzsa Z. Initial evidence of a 50% reduction of contrast media using digital variance angiography in endovascular carotid interventions. Eur J Radiol Open. 2020 Nov 17;7:100288. doi: 10.1016/j.ejro.2020.100288. eCollection 2020. |
| 27645233 | Background | Paraskevas KI, Mikhailidis DP. Contrast-Induced Acute Kidney Injury in Patients Undergoing Carotid Artery Stenting: An Underestimated Issue. Angiology. 2017 Oct;68(9):752-756. doi: 10.1177/0003319716668934. Epub 2016 Sep 19. |
| ID | Term |
|---|---|
| D002340 | Carotid Artery Diseases |
| ID | Term |
|---|---|
| D002561 | Cerebrovascular Disorders |
| D001927 | Brain Diseases |
| D002493 | Central Nervous System Diseases |
| D009422 | Nervous System Diseases |
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D062666 | Vascular Access Devices |
| ID | Term |
|---|---|
| D057785 | Catheters |
| D004864 | Equipment and Supplies |
Not provided
Not provided