Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The patients suspected coronary artery disease or those needing an angiography as per the inclusion criteria would be included after a 2d echocardiography and treadmill test/ stress myocardial stress imaging (if indicated) after a written and informed consent.
Anthropometric and lab paraments would be recorded.
Study will have 2 arms. I. A study arm 1 - baseline comparative arm of patients having undergone angiography with standard dose/ old low dose angiography.
II. A study arm 2 - a comparative arm where the patients being once eligible for the study; would undergo angiography using the new low dose protocol.
Post completion of the sample size the data of each angiographic view would be noted in both the study arms
INTRODUCTION
The increasing prevalence of cardiovascular diseases has led to a surge in the use of diagnostic angiography procedures. While these procedures are crucial for diagnosing and treating heart conditions, they also involve significant exposure to ionizing radiation. Excessive radiation exposure can pose serious health risks, including an increased risk of cancer and other adverse effects.
The RADRED study aims to address the critical issue of radiation exposure in cardiology catheterization labs. By comparing the radiation dose received by patients undergoing diagnostic angiography with and without a new low dose exposure protocol, the study seeks to evaluate the effectiveness of this protocol in reducing radiation exposure.
Several factors contribute to the need for such research. Firstly, the growing number of patients undergoing diagnostic angiography, particularly elderly individuals and those with multiple comorbidities, increases the cumulative radiation exposure to the population. Secondly, advancements in imaging technology have led to more complex procedures, often requiring longer fluoroscopy times, which can result in higher radiation doses. Finally, there is a growing awareness of the potential long-term health consequences of radiation exposure, particularly for vulnerable populations.
The RADRED study has the potential to make a significant contribution to the field of cardiology by demonstrating the feasibility and benefits of implementing a low dose exposure protocol in catheterization labs. By reducing radiation exposure, this protocol can help to protect the health of patients and healthcare providers, while also improving the overall efficiency and cost-effectiveness of diagnostic angiography procedures AIM To study determine the difference in the radiation exposure in diagnostic angiography with and without a new low dose exposure protocol
OBJECTIVES Primary objective To determine the difference in the radiation exposure levels received by patients undergoing diagnostic angiography with and without the new low dose exposure protocol.
Secondary objectives
STUDY DESIGN:
Observational analytical cohort study
PARTICIPANTS:
Inclusion criteria:
Adult patients who qualify for a need of diagnostic angiography and are finally found to have normal epicardial coronaries, e.g.:
Exclusion criteria:
STUDY METHOD:
The patients suspected coronary artery disease or those needing an angiography as per the inclusion criteria would be included after a 2d echocardiography and treadmill test/ stress myocardial stress imaging (if indicated) after a written and informed consent.
Anthropometric and lab paraments would be recorded.
Study will have 2 arms. I. A study arm 1 - baseline comparative arm of patients having undergone angiography with standard dose/ old low dose angiography.
II. A study arm 2 - a comparative arm where the patients being once eligible for the study; would undergo angiography using the new low dose protocol.
Post completion of the sample size the data of each angiographic view would be noted in both the study arms
PERIOD OF STUDY: till completion of sample in study arm 2 (each successive patient would be enrolled - cluster sample)
PATIENT CONSENT:
Appropriate approval will be obtained from IEC of the institute.
STATISTCAL ANALYSIS Data will be compiled in an excel sheet for all the variables of interest and presented in the form of tables and graphs as appropriate.
Measures of central tendency (mean or median) would be calculated for all quantitative variables along with measures of dispersion (standard deviation or interquartile range). Qualitative or categorical variables will be described as frequencies and proportions. The investigators will use a t-test for independent samples to compare the means of radiation exposure All the statistical analysis will be carried out using Statistical Package for Social Sciences (SPSS Inc., Chicago, IL, version 22.0 for Windows) at 5% level of significance i.e., p≤0.05 will be considered significant
ETHICAL JUSTIFICATION This study aims to evaluate the efficacy of a new low-dose radiation protocol for diagnostic angiography in cardiology Cath labs. By comparing patient radiation exposure with and without the protocol, the study seeks to reduce the cumulative radiation burden on patients, especially those at higher risk due to age or underlying health conditions. The increasing frequency of diagnostic angiography, coupled with advancements in imaging technology leading to more complex procedures, has resulted in a growing concern about the potential long-term health risks associated with radiation exposure. This study addresses this critical issue by exploring the effectiveness of a new protocol designed to minimize radiation dose during these procedures
. As, such low dose protocol has never been used earlier, there is a need for evaluating the same as to set new standards and protocols
The patients involved in the research project will be informed of the methods, anticipated benefits and potential risks of the study and the discomfort it may cause and the remedies thereof.
Written informed consent will be obtained. Every precaution will be taken to respect the privacy and confidentiality of the patient.
The parent has right to abstain from the study or to withdraw consent to participate at any time of the study without reprisal.
Due care and caution will be taken at all stages to ensure that the patient is put to minimum risk or suffer from irreversible side effects and probably benefit from study
DISCLOSURES/ CONFLICT OF INTEREST: NIL
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| A study arm 1 | baseline comparative arm of patients having already undergone angiography and fitting the inclusion criteria. The radiation exposure of this group would be collected from database of already done studies in the months prior to the initiation of the study (so as to prevent observer bias which may happen once the interventional cardiologist knows his inclusion in study, and may use a shorter or longer cine runs, thus influencing the outcomes). This would best represent the real-world data set, according to the routinely followed standard dose/ older low dose protocol. |
| |
| A study arm 2 | a comparative arm where the patients being once eligible for the study; would undergo angiography using the new low dose protocol. A total of 5 to 8 different views (orthogonal) would be taken (2 for RCA and 4 to 6 for LAD/LCX) |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Standard Dose Coronary angiography | Diagnostic Test | The radiation exposure of this group would be collected from database of already done studies in the months prior to the initiation of the study (so as to prevent observer bias which may happen once the interventional cardiologist knows his inclusion in study, and may use a shorter or longer cine runs, thus influencing the outcomes). This would best represent the real-world data set, according to the routinely followed standard dose/ older low dose protocol. |
| Measure | Description | Time Frame |
|---|---|---|
| To determine the difference in the radiation exposure levels received by patients undergoing diagnostic angiography with and without the new low dose exposure protocol | Study aims to address the critical issue of radiation exposure in cardiology catheterization labs. By comparing the radiation dose received by patients undergoing diagnostic angiography with and without a new low dose exposure protocol, the study seeks to evaluate the effectiveness of this protocol in reducing radiation exposure. | Through study completion, and average of 06 monhts |
Not provided
Not provided
Inclusion Criteria:
Adult patients who qualify for a need of diagnostic angiography and are finally found to have normal epicardial coronaries, e.g.:
Exclusion Criteria:
Not provided
Not provided
Not provided
Patients undergoing diagnostic angiography (age ≥18 years) will be included in the study.
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Dr Bharat S Sambyal, DM Card | Contact | +91 838 403 1327 | drbharatsambyal@gmail.com | |
| Dr R Anathakrishnan, DM Card | Contact | +91 750 611 1334 | anantha25@yahoo.com |
| Name | Affiliation | Role |
|---|---|---|
| Dr Bharat S Sambyal, DM Card | INHS Asvini | Principal Investigator |
| Dr R Anathakrishnan, DM Card | INHS Asvini | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| INHS Asvini | Mumbai | Maharashtra | 400005 | India |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 15001510 | Background | Picano E. Sustainability of medical imaging. BMJ. 2004 Mar 6;328(7439):578-80. doi: 10.1136/bmj.328.7439.578. | |
| 21051431 | Background | Padovani R, Le Heron J, Cruz-Suarez R, Duran A, Lefaure C, Miller DL, Sim HK, Vano E, Rehani M, Czarwinski R. International project on individual monitoring and radiation exposure levels in interventional cardiology. Radiat Prot Dosimetry. 2011 Mar;144(1-4):437-41. doi: 10.1093/rpd/ncq326. Epub 2010 Nov 3. |
| Label | URL |
|---|---|
| Radiation Units and Conversion Factors - Radiation Emergency Medical Management \[Internet\]. \[cited 2024 Sep 10\]. | View source |
Not provided
Currently there is no plan to share the IPD data due to government hospital data sharing restrictions. though anonymous data can be shared with a fellow researcher if a combined study is planned
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003324 | Coronary Artery Disease |
| ID | Term |
|---|---|
| D003327 | Coronary Disease |
| D017202 | Myocardial Ischemia |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D017023 | Coronary Angiography |
| D000792 | Angiography |
| ID | Term |
|---|---|
| D057791 | Cardiac Imaging Techniques |
| D003952 | Diagnostic Imaging |
| D019937 | Diagnostic Techniques and Procedures |
| D003933 | Diagnosis |
Not provided
Not provided
Not provided
Not provided
Not provided
|
|
| New low dose angiography | Diagnostic Test | a comparative arm where the patients being once eligible for the study; would undergo angiography using the new low dose protocol. |
|
| 34503751 | Background | Stocker TJ, Abdel-Wahab M, Mollmann H, Deseive S, Massberg S, Hausleiter J. Radiation Dose in Diagnostic Cardiac Catheterization: Results From the PROTECTION VII Study. JACC Cardiovasc Interv. 2021 Sep 13;14(17):1958-1960. doi: 10.1016/j.jcin.2021.07.023. No abstract available. |
| Background | Tong J, Hei TK. Aging and age-related health effects of ionizing radiation. Radiat Med Prot [Internet]. 2020 Mar 1 [cited 2024 Sep 10];1(1):15-23. Available from: https://www.sciencedirect.com/science/article/pii/S2666555720300058 |
| 30865914 | Background | Kar S, Teleb M, Albaghdadi A, Ibrahim A, Mukherjee D. Efficacy of Low-Dose Compared With Standard-Dose Radiation for Cardiac Catheterization and Intervention (KAR RAD Study). J Invasive Cardiol. 2019 Jun;31(6):187-194. doi: 10.25270/jic/18.00332. Epub 2019 Mar 15. |
| D001161 |
| Arteriosclerosis |
| D001157 | Arterial Occlusive Diseases |
| D014652 | Vascular Diseases |
| D011859 | Radiography |
| D003935 | Diagnostic Techniques, Cardiovascular |
| D006334 | Heart Function Tests |