Six patients with a single unit implant in the anterior maxilla (from premolar to premolar), after at least 3 months with provisional implant supported restoration will be submitted to definitive implant impressions.
Informed consents and local ethical committee clearance will be obtained. Patients will be submitted to a silicon impression with a customized impression coping from which a conventional cast will be obtained and scanned with D2000 (3Shape) and to an intraoral scan with Trios (3Shape). Standard Tessellation Language (STL) files will be obtained from both procedures and imported to reverse engineering software Geomagic Control X (3D Systems) and the distance between both scans will be calculated in a colored 3D map. From this map, two outcomes will be analyzed: the changes in soft tissues around implants with the two techniques (primary outcome) and the discrepancy between both scans in the teeth adjacent to the implants (secondary outcome).
"Custom-guided" tissue healing with o provisional restoration is the most predictable way to achieve natural anatomically shaped tissue and optimal esthetics. Several authors describe the use of an anatomically contoured provisional restoration to start to guide the soft tissue healing in an ideal, natural morphology that replicates the tooth form. Being that, after shaping the tissue to ideal anatomic form and health the exact duplication of the soft tissue contour should be obtained so that laboratory can duplicate it in the final restoration. Nowadays gold-standard, describes the use of a customized impression coping that replicates the provisional soft tissue contour by the use of and analog-silicone index upon which a gypsum cast is created.
The use of computer-aided design/computer-assisted manufacture (CAD/CAM) technologies to manufacture prosthetic frameworks on dental implants is noticeably increasing. This method requires the use of an STL file which can be acquired intra-orally or extraorally using a stone cast poured from a conventional implant impression using a customized implant impression coping.
Several studies have already described the accuracy of STL data and that evaluating STL models can be done by best fit algorithms in appropriate softwares.
In this pilot study, the investigators aim to evaluate soft tissue profile changes in single unit implants in the aesthetic area using a customized impression coping with conventional methods and the intraoral impression with an intraoral scanner (Trios, 3Shape). Additionally position discrepancies of adjacent teeth between the two techniques will be assessed.
This pilot study will include 6 patients with single unit implant which will be recruited according inclusion criteria and submitted to the two different impression techniques. Conventional stone cast will be scanned with a laboratory scanner D2000 (3Shape) with a described deviation of 5μm. Two STL files will be obtained per patient and by established methods with a reverse engineering software (Geomagic Control X, 3D Systems) discrepancies between them assessed.
Differences in axis (x, y, z) and overall distances will be assessed in the soft tissues (18 points) and in adjacent teeth (26 points) according established methods, per patient. Additionally, 3D colored maps will be produced to ascertain volumetric changes between techniques. T-test and Wilcoxon signed-rank test will be used and the level of statistical significance set at P<0.05. Sample size determination will be performed based on obtained results.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Dental implant Impression Techniques | Other | Dental implant impressions- Different Techniques An customized impression coping will be created based on the provisional crown emergence profile which will be used to perform a silicone implant impression. A conventional cast will be created based on the silicone impression and an extra-oral scanner reading will be performed with a 3shape D2000. An intra-oral scanner (Trios, 3Shape) will be used to scan the entire arch. The STL file created will be compared and tooth positions and soft tissues discrepancies will be determined |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Dental implant impressions- Different Techniques | Device | Assessment of soft tissues changes with different techniques |
|
| Measure | Description | Time Frame |
|---|---|---|
| Changes in Soft Tissues Around Implant | Discrepancies in soft tissues around implants between different techniques, conventional and digital, in a single unit implant impression, measured as root mean square in µm. | Both techniques will be used in the same appointment upon 3 months use of provisional crown |
| Measure | Description | Time Frame |
|---|---|---|
| Discrepancy (Trueness) Between STL Files in Teeth Adjacent to Implant | Linear measurements in µm between STL files in teeth adjacent to implant in several pre-defined locations | Both techniques will be used in the same appointment upon 3 months use of provisional crown |
Not provided
Inclusion Criteria:
Exclusion Criteria:
- Patients without soft tissue contouring or without provisional implant supported use
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Duarte Marques, DDS, PhD | Implantology Institute | Principal Investigator |
| João Caramês, DDS, PhD | Implantology Institute | Study Director |
| Antonio Mata, DDS, PhD | Grupo de Investigação em Bioquímica e Biologia Oral | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Instituto de Implantologia | Lisbon | 1070-064 | Portugal |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
be at least 18 years of age; have at least one implant in the anterior maxilla with the indication for rehabilitation with a definitive implant supported crown; have two mesial and two distal adjacent teeth to the implant and be rehabilitated with a provisional implant supported crown for at least 3 months.
| ID | Title | Description |
|---|---|---|
| FG000 | Dental Implant Impression Techniques | Dental implant impressions- Different Techniques An customized impression coping will be created based on the provisional crown emergence profile which will be used to perform a silicone implant impression. A conventional cast will be created based on the silicone impression and an extra-oral scanner reading will be performed with a 3shape D2000. An intra-oral scanner (Trios, 3Shape) will be used to scan the entire arch. The STL file created will be compared and tooth positions and soft tissues discrepancies will be determined Dental implant impressions- Different Techniques: Assessment of soft tissues changes with different techniques |
| Title | Milestones | Reasons Not Completed | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Dental Implant Impression Techniques | Dental implant impressions- Different Techniques An customized impression coping will be created based on the provisional crown emergence profile which will be used to perform a silicone implant impression. A conventional cast will be created based on the silicone impression and an extra-oral scanner reading will be performed with a 3shape D2000. An intra-oral scanner (Trios, 3Shape) will be used to scan the entire arch. The STL file created will be compared and tooth positions and soft tissues discrepancies will be determined Dental implant impressions- Different Techniques: Assessment of soft tissues changes with different techniques |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Mean |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Changes in Soft Tissues Around Implant | Discrepancies in soft tissues around implants between different techniques, conventional and digital, in a single unit implant impression, measured as root mean square in µm. | Patients with a single implant in the esthetic anterior maxillar zone in need of a definitive crown. | Posted | Mean | 95% Confidence Interval | root mean square in µm | Both techniques will be used in the same appointment upon 3 months use of provisional crown |
|
6 months
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Dental Implant Impression Techniques | Dental implant impressions- Different Techniques An customized impression coping will be created based on the provisional crown emergence profile which will be used to perform a silicone implant impression. A conventional cast will be created based on the silicone impression and an extra-oral scanner reading will be performed with a 3shape D2000. An intra-oral scanner (Trios, 3Shape) will be used to scan the entire arch. The STL file created will be compared and tooth positions and soft tissues discrepancies will be determined Dental implant impressions- Different Techniques: Assessment of soft tissues changes with different techniques |
Not provided
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Prof. Dr. Duarte Marques | Implantology Institute | +351217 210 980 | d.marques@institutoimplantologia.com |
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | Mar 25, 2019 | Jul 12, 2019 | Prot_SAP_000.pdf |
Not provided
To describe the soft tissues dimensional changes (based on STL files) occurred between an intra-oral scanner and standartized scan-body and a extra-oral scanner of stone cast poured from silicone impression with a customized impression coping
12 months after implant placement and simultaneous regeneration with L-PRF and bovine bone graft in the aesthetic zone of atrophic maxillae in full arch implant supported rehabilitations
Not provided
Not provided
Altough it is a single arm two different techniques will be used and obtained STL files will be identified as A and B and the outcomes assessor will not be informed which group corresponds to intra-oral scanner and extra-oral scanner
Not provided
| years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Race and Ethnicity Not Collected | Race and Ethnicity were not collected from any participant. | Count of Participants | Participants |
|
|
|
| Secondary | Discrepancy (Trueness) Between STL Files in Teeth Adjacent to Implant | Linear measurements in µm between STL files in teeth adjacent to implant in several pre-defined locations | Patients in need of a definitive crown in a single implant in the esthetic anterior maxillar zone. | Posted | Mean | 95% Confidence Interval | Root mean square in μm | Both techniques will be used in the same appointment upon 3 months use of provisional crown |
|
|
|