Presurgical evaluation of epileptic patients require a precise mapping of cerebral regions implied in epileptic discharges and in normal function.
The current practice in most cases is to implant intracerebral electrodes in order to localize these regions in a reliable manner. However, non-invasive methods have been developed in order to record brain activity with no risk for the patient.
Still, it is necessary to validate and improve the signal processing methods and the underlying models these methods in order to optimize their use in clinical practice. To do so, it is necessary to record simultaneously electroencephalogram (EEG) and magnetoencephalogram (MEG) and stereo encephalogram SEEG (intracerebral). Such simultaneous recordings will permit to confront the exact same activity recorded non-invasively at the surface of the head, and represented on the brain thanks to the model and directly within the brain.
The objective is to define the conditions under which one can represent faithfully the activity measured intracerebrally from the surface measurements.
It will be record simultaneously MEG, scalp EEG and intracerebral EEG on a series of 60 patients. It will be record resting state signals, as well as stimulation protocols. The interictal epileptic discharges will be marked on the different modalities, and evoked potentials/fields computed in response to protocols. Sensitivity of recordings to activity visible on depth recordings will be evaluated as a function of localization of brain generators. Advanced signal processing methods will be used such as source localization and independent component analysis, in order to increase sensitivity of measures.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| registration of intracerebral activity | Experimental | epileptic patient receiving implantation of intracranial electrodes |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| electroencephalogram | Device | Implanting electrode to measure brain activity |
|
| Measure | Description | Time Frame |
|---|---|---|
| The number of epileptic discharges | Measurement of epileptic activity by electroencephalogram | 60 months |
Not provided
Not provided
Inclusion Criteria:
- Patients for whom implanting intracerebral electrodes is underway
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Assistance Publique Hôpitaux de Marseille | Marseille | 13354 | France |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 24862073 | Result | Dubarry AS, Badier JM, Trebuchon-Da Fonseca A, Gavaret M, Carron R, Bartolomei F, Liegeois-Chauvel C, Regis J, Chauvel P, Alario FX, Benar CG. Simultaneous recording of MEG, EEG and intracerebral EEG during visual stimulation: from feasibility to single-trial analysis. Neuroimage. 2014 Oct 1;99:548-58. doi: 10.1016/j.neuroimage.2014.05.055. Epub 2014 May 23. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D004827 | Epilepsy |
| ID | Term |
|---|---|
| D001927 | Brain Diseases |
| D002493 | Central Nervous System Diseases |
| D009422 | Nervous System Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D004569 | Electroencephalography |
| D015225 | Magnetoencephalography |
| ID | Term |
|---|---|
| D003943 | Diagnostic Techniques, Neurological |
| D019937 | Diagnostic Techniques and Procedures |
| D003933 | Diagnosis |
| D004568 | Electrodiagnosis |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| magnetoencephalogram | Device | Implanting electrode to measure brain activity |
|
| D060306 | Magnetometry |
| D008919 | Investigative Techniques |