Primary objective is to assess the impact of different reference glucose measurement methods on the measured performance of a CGM system, aiming at further standardization for the assessment of CGM systems. Secondary objective is to describe the relationship between glucose concentration of venous, capillary and arterialized-venous measurement samples.
Study design: Open-label trial. Study population: Nineteen patients with type 1 diabetes aged 18 years and older will be included.
Intervention: The study will use the Dexcom G5 Mobile CGM. The participant will visit the clinical research center (CRC) twice during a 6 day period. These visits will have a duration of 8 hours. Blood will be drawn for the determination of glucose concentrations using venous, arterialized-venous and capillary sampling techniques. The patient will receive his usual breakfast and an increased insulin bolus will be administered to correct the breakfast glucose excursion with the aim of inducing a period of minor hypoglycemia. Blood sampling will continue until the end of the admission. The sensor will be worn until the end of the second 8-hour CRC session, which will be planned on day 6 or earlier depending on patient preference. The sensor will be removed and their sensor and blood glucose meter data downloaded from the devices. In the case of sensor failure before the first CRC session, patients will be instructed to insert a new sensor per the manufacturer's instruction and to notify study staff of the event. In case of failure of the sensor after the first CRC session but before the second CRC session, patients will return to the CRC for sensor removal and for data download.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Arterialized-venous reference YSI | Experimental | CGM monitoring performance per arterialized venous reference measurement (YSI) |
|
| Venous reference samples YSI | Experimental | CGM monitoring performance per venous reference measurement (YSI) |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Arterialized-venous reference (YSI) | Device | All patients will be fitted with the a CGM system, Dexcom G5 Mobile, patients receive an iv-catheter to sample venous blood. The samples will be arterialized using a heated-hand-box (arterialized-venous reference (YSI). Blood will be drawn for the determination of glucose concentrations using arterialized-venous sampling techniques per YSI. |
| Measure | Description | Time Frame |
|---|---|---|
| Mean Absolute Relative Difference (MARD) | MARD will be assessed per average of the 8 hour arterialization and regular venous study visit. | up to day 6 of use |
| Measure | Description | Time Frame |
|---|---|---|
| Accuracy of sensors (MARD) per hypoglycemic range | Accuracy of the sensor in the hypoglycaemic (defined as a blood glucose value ≤70 mg/dL) area as an average of the first six days of use. | up to day 6 of use |
| Accuracy (MARD) of sensors per hyperglycemic range |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Academic Medical Center | Amsterdam | North Holland | 1105AZ | Netherlands |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003922 | Diabetes Mellitus, Type 1 |
| ID | Term |
|---|---|
| D003920 | Diabetes Mellitus |
| D044882 | Glucose Metabolism Disorders |
| D008659 | Metabolic Diseases |
| D009750 | Nutritional and Metabolic Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Venous reference measurement (YSI) | Device | All patients will be fitted with the a CGM system, Dexcom G5 Mobile, patients receive an iv-catheter to sample venous blood. Blood will be drawn for the determination of glucose concentrations using venous sampling techniques measured per YSI. |
|
| Capillary reference (SMBG) | Device | All patients will be fitted with the a CGM system, Dexcom G5 Mobile, patients receive vingerstick measurements to sample capillary blood measured per Self Monitoring of Blood Glucose (SMBG) device. |
|
Accuracy of the sensor in the hyperglycaemic (defined as a blood glucose value >180 mg/dL) area as an average of the first six days of use. |
| up to day 6 of use |
| Glucose content (mg/dL) of venous reference samples. | Glucose content of venous reference samples will be measured per YSI. | Up day 6 of study during both intervention visits |
| Glucose content (mg/dL) of venous-arterialized reference samples. | Glucose content of venous-arterialized reference samples will be measured per YSI. | up day 6 of study during both intervention visits |
| Glucose content (mg/dL) of capillary reference samples. | Glucose content of capillary reference samples will be measured per SMBG. | up day 6 of study during both intervention visits |
| D004700 | Endocrine System Diseases |
| D001327 | Autoimmune Diseases |
| D007154 | Immune System Diseases |