Proposed comparison (RetCam vs. COSMOS) was unfeasible. Device is now licensed in Canada.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Phoenix Clinical Inc. | INDUSTRY |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The purpose of this study is to compare the RetCam (Clarity Medical Systems, Pleasanton, CA) to a new prototype pediatric imaging system, COSMOS, produced by Phoenix Clinical Incorporated (PCI) (Pleasanton, CA).
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| PCI imaging system | Experimental |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Examination under anaesthetic (EUA) | Procedure | The EUA is scheduled as part of the routine clinical management of children with various ophthalmic conditions. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Comparison of the field of view in RetCam and COSMOS images | Masked investigators will review images from the RetCam and the COSMOS. Field of view will be graded on a scale from 1-5, with 1 being the worst and 5 being the best. We will test for significant difference, at alpha level 0.05, between scores of the images taken by the RetCam and the COSMOS. | 1 day |
| Comparison of the color in RetCam and COSMOS images | Masked investigators will review images from the RetCam and the COSMOS. Color will be graded on a scale from 1-5, with 1 being the worst and 5 being the best. We will test for significant difference, at alpha level 0.05, between scores of the images taken by the RetCam and the COSMOS. | 1 day |
| Comparison of the dynamic range in RetCam and COSMOS images | Masked investigators will review images from the RetCam and the COSMOS. Dynamic range will be graded on a scale from 1-5, with 1 being the worst and 5 being the best. We will test for significant difference, at alpha level 0.05, between scores of the images taken by the RetCam and the COSMOS. | 1 day |
| Comparison of the sharpness in RetCam and COSMOS images | Masked investigators will compare images from the RetCam and the COSMOS and grade sharpness on a scale from 1-5, with 1 being the worst and 5 being the best. We will test for significant difference, at alpha level 0.05, between scores of the images taken by the RetCam and the COSMOS. | 1 day |
| Comparison of the detail in RetCam and COSMOS images | Masked investigators will review images from the RetCam and the COSMOS. Detail will be graded on a scale from 1-5, with 1 being the worst and 5 being the best. We will test for significant difference, at alpha level 0.05, between scores of the images taken by the RetCam and the COSMOS. |
Not provided
Not provided
Exclusion Criteria:
Inclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Brenda L Gallie, MD, FRCSC | The Hospital for Sick Children | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| The Hospital for Sick Children | Toronto | Ontario | M5G1X8 | Canada |
Not provided
| ID | Term |
|---|---|
| D012175 | Retinoblastoma |
| ID | Term |
|---|---|
| D018302 | Neoplasms, Neuroepithelial |
| D017599 | Neuroectodermal Tumors |
| D009373 | Neoplasms, Germ Cell and Embryonal |
| D009370 | Neoplasms by Histologic Type |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| RetCam | Device | The RetCam is a pediatric wide-field retinal camera that has been the mainstay for pediatric ophthalmic imaging since 1997. Imaging using the RetCam (during the EUA) is conducted as part of routine clinical magagement. |
|
| COSMOS | Device | The COSMOS images will be captured (during the EUA) after the RetCam images. The COSMOS is designed to be used in the same way as the RetCam, but to produce higher quality images. |
|
| 1 day |
| Comparison of the resolution in RetCam and COSMOS images | Masked investigators will review images from the RetCam and the COSMOS. Resolution will be graded on a scale from 1-5, with 1 being the worst and 5 being the best. We will test for significant difference, at alpha level 0.05, between scores of the images taken by the RetCam and the COSMOS. | 1 day |
| Comparison of the evenness of illumination in RetCam and COSMOS images | Masked investigators will review images from the RetCam and the COSMOS. Evenness of illumination will be graded on a scale from 1-5, with 1 being the worst and 5 being the best. We will test for significant difference, at alpha level 0.05, between scores of the images taken by the RetCam and the COSMOS. | 1 day |
| D009369 | Neoplasms |
| D009375 | Neoplasms, Glandular and Epithelial |
| D009380 | Neoplasms, Nerve Tissue |
| D019572 | Retinal Neoplasms |
| D005134 | Eye Neoplasms |
| D009371 | Neoplasms by Site |
| D015785 | Eye Diseases, Hereditary |
| D005128 | Eye Diseases |
| D012164 | Retinal Diseases |