The primary objective of the study is to evaluate the safety and effectiveness of the G4 System (System) when used as an adjuvant to blood glucose testing over a 7-day period in pediatric subjects with diabetes mellitus.
System effectiveness will be primarily evaluated with comparison to laboratory reference Yellow Springs Instrument (YSI) venous sample measurements. The system performance will be evaluated in terms of point and rate accuracy of the system in reference to YSI. The point accuracy is measured as the proportion of G4 System values that are within ±20% of YSI reference value for glucose levels >80 mg/dL and ±20 mg/dL at YSI glucose levels <80 mg/dL. The trend accuracy of the device performance, i.e., continuous glucose error grid analysis, will be evaluated as well as the temporal accuracy at different glucose rates of changes and different glucose ranges (hypoglycemic, euglycemic, and hyperglycemic ranges). The primary matched paired (Sensor-YSI) measurements will be collected during one in-clinic session. System effectiveness will also be evaluated with SMBG measurements similarly.
Safety data of the system will also be collected and safety will be characterized by the incidence of Adverse Device Effects (ADE) experienced by study participants.
Other objectives include the evaluation of device performance at an alternate site (the upper buttocks).
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Pediatric subjects with diabetes mellitus |
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| System Performance Effectiveness | The primary objective is to characterize System effectiveness in comparison with the laboratory reference YSI venous sample measurements. | 7 days |
| Measure | Description | Time Frame |
|---|---|---|
| System Performance at Alternate Wear Site | An additional objective is to evaluate System performance at an alternate wear site. The System performance will be assessed, using the same statistical methodology as the primary wear site. | 7 days |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Pediatric subjects with diabetes mellitus
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Advanced Metabolic Care and Research | Escondido | California | 92026 | United States | ||
| CHOC Children's |
Not provided
Not provided
Not provided
Not provided
| Orange |
| California |
| 92868 |
| United States |
| Stanford University | Stanford | California | 94305 | United States |
| Barbara Davis Center | Aurora | Colorado | 80045 | United States |
| Rocky Mountain Diabetes and Osteoporosis Center, PA | Idaho Falls | Idaho | 83404 | United States |
| Joslin Diabetes Center | Boston | Massachusetts | 02215 | United States |
| ID | Term |
|---|---|
| D003920 | Diabetes Mellitus |
| ID | Term |
|---|---|
| D044882 | Glucose Metabolism Disorders |
| D008659 | Metabolic Diseases |
| D009750 | Nutritional and Metabolic Diseases |
| D004700 | Endocrine System Diseases |
Not provided
Not provided