Pregnant patients having a cesarean section (CS) under spinal anesthesia experience a variety of hemodynamic changes, such as hypotension due to decreases in cardiac output (CO), stroke volume (SV) and/or systemic vascular resistance (SVR). Measurement of these hemodynamic parameters classically requires insertion of a pulmonary artery catheter (PAC) into the heart. However, this invasive method carries significant complications and its use is now reserved for the more critically ill patients. We hypothesize that the Physioflow Impedance device can be used as a reliable non-invasive monitor to measure hemodynamic parameters during elective CS under spinal anesthesia.
The Physioflow Impedance device employs a continuous non-invasive method of measuring ten cardiac hemodynamic parameters including flow, resistance, contractility and fluid content. It involves the application of electrocardiogram (ECG) leads on the neck and the thorax to measure resistance of pulsatile blood flow. Its benefits are that it is non-invasive, low cost, and easy to operate. Thoracic impedance has been validated against the gold standard method of PAC. Although the Physioflow device has been validated in non-pregnant patients, its use in pregnant patients is very limited.
Moderate to severe hypotension, experienced by these awake patients, can cause significant undesirable symptoms of dizziness, shortness of breath, nausea and vomiting, and also compromise fetal well-being. The etiology of hypotension is multi-factorial,and it is postulated that decreases in cardiac output (CO), stroke volume (SV) and/or systemic vascular resistance (SVR) may precede decreases in blood pressure. Continuous measurement of CO and SV by the Physioflow Impedance device may provide a better understanding of the cause of hypotension so that future management of these patients may include pharmacological interventions used prior to hypotension in order to avoid any undesirable symptoms.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| 1 | Elective cesarean section patients |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Physioflow Impedance | Device | 6 ECG leads applied to the neck and thorax for the duration of surgery (approximately 1 hour). |
|
| Measure | Description | Time Frame |
|---|---|---|
| Continuous measurement of cardiac output (CO), stroke volume (SV) and/or systemic vascular resistance (SVR) changes. | 60 minutes |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Healthy volunteers having an elective cesarean section.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Kong Eric You-Ten, MD | MOUNT SINAI HOSPITAL | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Mount Sinai Hospital | Toronto | Ontario | M5G1X5 | Canada |
Not provided
| ID | Term |
|---|---|
| D007022 | Hypotension |
| ID | Term |
|---|---|
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided