The aim of the present study is the optimization of various magnetic resonance (MR) investigation protocols of the heart and the lung without contrast agent application as well as the generation of normal values from cardiac MR images. One of the main problems in cardiac MR investigations is the strong dependence of the achieved image quality on optimal settings of sequence parameters and anatomical and physiological situations with special emphasis on phase-contrast imaging and other cine-techniques.
Time optimized and well organized MR protocols for the cardiac and lung investigations are evaluated on normal subjects with special respect to following topics:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
healthy volunteers
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Gert Reiter, DI Dr. | Siemens Medical Solutions | Principal Investigator |
| Ursula Reiter, DI Dr. | Universitäts-Frauenklinik Graz | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Medical Unitersity Graz, Allgemeine Radiologische Diagnostik | Graz | Stmk | 8036 | Austria |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 17670255 | Result | Reiter G, Reiter U, Bergmann P, Rienmuller R. MR imaging-based port placement planning for totally endoscopic coronary artery bypass grafting. Interact Cardiovasc Thorac Surg. 2004 Jun;3(2):341-5. doi: 10.1016/j.icvts.2004.01.015. | |
| 15489068 | Result | Reiter G, Reiter U, Rienmuller R, Gagarina N, Ryabikin A. On the value of geometry-based models for left ventricular volumetry in magnetic resonance imaging and electron beam tomography: a Bland-Altman analysis. Eur J Radiol. 2004 Nov;52(2):110-8. doi: 10.1016/j.ejrad.2003.10.003. |
Not provided
Not provided
Not provided
| 19808511 | Result | Reiter G, Reiter U, Kovacs G, Kainz B, Schmidt K, Maier R, Olschewski H, Rienmueller R. Magnetic resonance-derived 3-dimensional blood flow patterns in the main pulmonary artery as a marker of pulmonary hypertension and a measure of elevated mean pulmonary arterial pressure. Circ Cardiovasc Imaging. 2008 Jul;1(1):23-30. doi: 10.1161/CIRCIMAGING.108.780247. |