To compare Bispectral index and entropy during maintenance of anesthesia
Several monitors are currently proposed to evaluate the depth of hypnosis. Among them, Bispectral Index (BIS) is a well known and widely used parameter derived from the patient's electroencephalograph (EEG). Spectral entropy relies on the extent of disorder in both EEG and electromyography (EMG) signals and returns 2 values: State Entropy (SE) and Response Entropy. SE is computed over the frequency range of 0.8-32 Hz and reflects the level of hypnosis while Response Entropy is computed over the frequency range of 0.8-47 Hz and reflects also EMG activity. BIS and SE are dimensionless numbers scaled from 100 to 0 for BIS and from 91 to 0 for SE.
The BIS and Entropy manufacturers claim that adequate level of anesthesia is defined by a BIS or SE value between 40 and 60. But some observations have shown that the monitors provided different information. These observations led us to carry out this prospective observational study designed to study the comparability between BIS and SE during the maintenance period of propofol-sufentanil anesthesia.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Bispectral index, Entropy | Device |
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Marc Fischler, MD | Hôpital Foch | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Dept of Anesthesia and Intensive Care, Hôpital Beaujon | Clichy | 92110 | France | |||
| Dept of Anesthesiology, Hôpital Foch |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 15564934 | Background | Schmidt GN, Bischoff P, Standl T, Hellstern A, Teuber O, Schulte Esch J. Comparative evaluation of the Datex-Ohmeda S/5 Entropy Module and the Bispectral Index monitor during propofol-remifentanil anesthesia. Anesthesiology. 2004 Dec;101(6):1283-90. doi: 10.1097/00000542-200412000-00007. | |
| 15220769 | Background |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Suresnes |
| 92150 |
| France |
| Vanluchene AL, Vereecke H, Thas O, Mortier EP, Shafer SL, Struys MM. Spectral entropy as an electroencephalographic measure of anesthetic drug effect: a comparison with bispectral index and processed midlatency auditory evoked response. Anesthesiology. 2004 Jul;101(1):34-42. doi: 10.1097/00000542-200407000-00008. |
| 22258203 | Derived | Aime I, Gayat E, Fermanian C, Cook F, Peuch C, Laloe PA, Mantz J, Fischler M. Effect of age on the comparability of bispectral and state entropy indices during the maintenance of propofol-sufentanil anaesthesia. Br J Anaesth. 2012 Apr;108(4):638-43. doi: 10.1093/bja/aer457. Epub 2012 Jan 17. |