The main objective of the study is to determine whether depth of anesthesia (DOA) monitoring such as Bispectral Index (BIS) and entropy are accurate in patients with neuro-psychological conditions such as Parkinson's disease by comparing these monitoring with standard clinical monitoring like heart rate, blood pressure and respiratory rate.
Deep brain simulation (DBS) is an increasingly popular treatment for movement and psychiatric disorders such as Parkinson's disease and dystonia. These patients are quite sensitive to anesthetics and use of depth of anesthesia monitors are often needed to titrate the anesthetics. The calibration of BIS and entropy monitors has been done only on subjects with no neurological diseases. The investigators plan to record BIS and entropy readings during general anesthesia (GA) for the internalization of DBS electrodes. This would be useful as there are very few studies in this subset of patients with regards to DOA monitoring. Ashraf argued that the EEG may be altered under these circumstances and hence produce invalid BIS readings. Pemberton et al. studied patients undergoing tumour surgery using a sleep- awake-sleep anaesthesia technique. They found a poor correlation between BIS values and the observer's assessment of anesthesia level, suggesting that BIS is not a reliable tool for patients with brain abnormalities. The purpose of this study was to investigate whether BIS and entropy are helpful in titrating DOA in patients undergoing neurosurgical procedures or suffering from neurological diseases as they were frequently excluded from validation studies of the BIS monitoring device.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| BIS and Entropy monitoring | Depth of anesthesia monitoring (BIS and entropy) are compared with standard clinical monitoring in patients with deep brain stimulators inserted at internalization whilst they are having a general anesthesia. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| BIS monitor | Device | Both types of depth of anesthesia monitoring (BIS and entropy- electrodes) are applied on patients together with standard monitoring (heart rate, blood pressure, respiratory rate). The two different types of depth of anesthesia monitoring are then compared. |
| Measure | Description | Time Frame |
|---|---|---|
| Correlation Between Bispectral (BIS) and Response Entropy (RE) Indices | The trends of Bispectral (BIS) and Response entropy (RE) at different study time points. Bispectral (BIS) and Response entropy (RE) values range from 0 (absence of brain activity) to 100 (fully awake state). Values below 40 indicate deep anesthesia, values from 40 to 60 optimal and above 60 but below 90 inadequate anesthesia. | One day |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Patients having a general anesthesia post DBS insertion for the internalization of DBS.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Lashmi Venkatraghavan | University Health Network, Toronto Western Hospital | Principal Investigator |
| Pirjo Manninen | University Heath Network, Toronto Western Hospital | Principal Investigator |
| Audrey MY Tan | University Heath Network, Toronto Western Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University Heath Network, Toronto Western Hospital | Toronto | Ontario | M5T 2S8 | Canada |
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | BIS and Entropy Monitoring | Depth of anesthesia monitoring (BIS and entropy) are compared with standard clinical monitoring in patients with deep brain stimulators inserted at internalization whilst they are having a general anesthesia. BIS monitor: Both types of depth of anesthesia monitoring (BIS and entropy- electrodes) are applied on patients together with standard monitoring (heart rate, blood pressure, respiratory rate). The two different types of depth of anesthesia monitoring are then compared. Entropy monitor: Both types of depth of anesthesia monitoring (BIS and entropy- electrodes) are applied on patients together with standard monitoring (heart rate, blood pressure, respiratory rate). The two different types of depth of anesthesia |
| Title | Milestones | Reasons Not Completed | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
Demographic data values are presented as (mean±SD)
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | BIS and Entropy Monitoring | Depth of anesthesia monitoring (BIS and entropy) are compared with standard clinical monitoring in patients with deep brain stimulators inserted at internalization whilst they are having a general anesthesia. BIS monitor: Both types of depth of anesthesia monitoring (BIS and entropy- electrodes) are applied on patients together with standard monitoring (heart rate, blood pressure, respiratory rate). The two different types of depth of anesthesia monitoring are then compared. Entropy monitor: Both types of depth of anesthesia monitoring (BIS and entropy- electrodes) are applied on patients together with standard monitoring (heart rate, blood pressure, respiratory rate). The two different types of depth of anesthesia |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Customized | Mean |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Correlation Between Bispectral (BIS) and Response Entropy (RE) Indices | The trends of Bispectral (BIS) and Response entropy (RE) at different study time points. Bispectral (BIS) and Response entropy (RE) values range from 0 (absence of brain activity) to 100 (fully awake state). Values below 40 indicate deep anesthesia, values from 40 to 60 optimal and above 60 but below 90 inadequate anesthesia. | Correlation analysis between BIS and RE from pre-induction time (T1) until the surgical closure time (T9) Bispectral (BIS) and Response entropy (RE) values range from 0 (absence of brain activity) to 100 (fully awake state). Values below 40 indicate deep anesthesia, values from 40 to 60 optimal and above 60 but below 90 inadequate anesthesia. | Posted | Mean | Standard Deviation | units on a scale | One day |
|
one day
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | BIS and Entropy Monitoring | Depth of anesthesia monitoring (BIS and entropy) are compared with standard clinical monitoring in patients with deep brain stimulators inserted at internalization whilst they are having a general anesthesia. BIS monitor: Both types of depth of anesthesia monitoring (BIS and entropy- electrodes) are applied on patients together with standard monitoring (heart rate, blood pressure, respiratory rate). The two different types of depth of anesthesia monitoring are then compared. Entropy monitor: Both types of depth of anesthesia monitoring (BIS and entropy- electrodes) are applied on patients together with standard monitoring (heart rate, blood pressure, respiratory rate). The two different types of depth of anesthesia |
Not provided
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Emad Al Azazi | Toronto Western Hospital/UHN | 416-603-8500 | 6237 | emad.alazazi@uhnresearch.ca |
Not provided
| ID | Term |
|---|---|
| D009069 | Movement Disorders |
| ID | Term |
|---|---|
| D002493 | Central Nervous System Diseases |
| D009422 | Nervous System Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Entropy monitor | Device | Both types of depth of anesthesia monitoring (BIS and entropy- electrodes) are applied on patients together with standard monitoring (heart rate, blood pressure, respiratory rate). The two different types of depth of anesthesia |
|
| years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Race and Ethnicity Not Collected | Race and Ethnicity were not collected from any participant. | Count of Participants | Participants |
|
| OG001 | Response Entropy Index | The trends of Response Entropy index (RE) at different study time points (T) |
|
|
| 0 |
| 30 |
| 0 |
| 30 |
| 0 |
| 30 |
Not provided
Not provided
Not provided