Keeping a patient's body temperature normal during surgery is an important part of safe anesthetic care. When the body temperature drops below 36°C (called inadvertent perioperative hypothermia), patients face higher risks of bleeding, wound infection, heart problems, and a slower recovery. To prevent these complications, anesthesiologists monitor core body temperature continuously during surgery.
Three monitoring methods are commonly used in clinical practice: (1) a nasopharyngeal probe - a small soft sensor inserted through the nose and placed at the back of the throat, which provides continuous readings and is considered the gold standard; (2) an infrared tympanic thermometer (TaiDoc TD-1261) - a handheld device that measures ear temperature in about one second; and (3) the 3M SpotOn™ sensor - a non-invasive adhesive patch placed on the forehead that continuously estimates core temperature without requiring insertion into any body cavity.
Although all three methods are used interchangeably at Srinagarind Hospital, no study has directly compared all three simultaneously in the same patient to determine how well they agree with each other. If significant differences exist between methods, a clinician who switches from one device to another may unknowingly under-detect or over-estimate hypothermia.
This study will enroll 92 adult patients scheduled for elective surgery under general anesthesia at Srinagarind Hospital, Khon Kaen University. All three temperature sensors will be applied at the same time, and readings will be recorded simultaneously every 15 minutes throughout the operation. The main goal is to determine whether each device gives results close enough to the nasopharyngeal probe to be safely used as an alternative. The study is observational - no medications or procedures will be added to routine care.
Inclusion Criteria:
Group 1: Cardiac surgery Group 2: Thoracic surgery Group 3: General surgery, including neurosurgery
Exclusion Criteria:
thepakorns@gmail.com
Adult patients (age ≥ 18 years) undergoing elective surgery under general anesthesia with tracheal intubation at Srinagarind Hospital and Queen Sirikit Heart Center of the Northeast, Khon Kaen University, with an expected surgical duration ≥ 60 minutes and ASA Physical Status I-III. All participants have all three temperature monitoring devices (NP probe, TaiDoc TD-1261 IR tympanic thermometer, and 3M SpotOn™ ZHF sensor) applied simultaneously following induction of anesthesia.
sirirat.tribuddharat@gmail.com66816205920
Intraoperative Body Temperature Measurement Using Infrared Camera: Comparison With Esophageal, and Skin Temperatures
Optimal Positioning of Nasopharyngeal Temperature Probes: A Prospective Cohort Study
Temperature Measurement in Surgical and Intensive Care Patients - Comparison of Four Measurement Methods