Not provided
We proposed to compare in an observational study procedural success at one month (VARC 3 criteria) and clinical and echographic follow-up at 6 months between 2 self expandable devices in TAVR : the supra annular Evolut device (Medtronic) vs the intra anular NAVITOR device (Abott)
Compared with balloon-expandable valves, self-expandable supra annular devices (Mertronic Evolut) offer superior post-procedural hemodynamics in TAVR and are, therefore, expected to play a growing role in clinical practice particularly in small aortic anatomies . However, the relatively long stent frame of self-expandable valves posed challenges for coronary access after implantation and PPI rates remain higher, despite lower implantation height with the cusp overlap technique The Navitor valves (Abbott Structural Valve) is a new generation intra-annular self-expandable device with tall stent frame but larger stent cells and shorter outer skirt which may be more favorable for future coronary access than the Evolut FX valves, particularly in patients with lower coronary heights . The Navitor platform showed satisfying data in tricuspid anatomy, providing intra-annular leaflets, an innovative sealing cuff, and repositionability .However this platform showed a high rate of PPI that could be related to the need for lower implantation to stabilize the device (first generation) Considering the lack of specific data regarding the compared performance of the 2 plateforms including latest generation devices, we aimed to evaluate procedural success, clinical and hemodynamic results, and conductive disorders between the 2 platforms in an observational real life study
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| patients with indication of TAVR - supra annular design device | TAVR with self expandable supra annular design device (EVOLUT) | ||
| patients with indication of TAVR - intra annular design device | TAVR with self expandable intra annular design device |
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Device success according to VARC 3 criteria | 1 month follow up |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
patients with indication of femoral TAVR for aortic stenosis after heart team decision
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Florence LECLERCQ, MD | Contact | +33467336212 | f-leclercq@chu-montpellier.fr |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University hopsital | Recruiting | Montpellier | Occitanie | 34295 | France |