Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Beirut Arab University | OTHER |
Not provided
Not provided
Not provided
Aim of the study is to analyze and compare the characteristic differences occurring in the surrounding bone in an immediate implant placed by osseodensification to immediate implants placed with the conventional technique
A bifurcation inter-radicular bone of 2 mm or more in a none restorable lower molar will be needed in order to successfully be able to drill the bone with conventional or Osseo densification burs, followed by placing the implant at this site. A xenograft bone material will be used to fill the extraction socket and a customized temporary abutment using flowable composite and a silicone mold will be fabricated and placed over it after polishing it.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Osseodensification burs | Experimental |
| |
| Conventional Burs | Active Comparator |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Osseodensification burs | Other | Densah burs are osseodensification burs used to condense bone and prepare dental implant site, unlike conventional technique which cuts and removes the bone |
| Measure | Description | Time Frame |
|---|---|---|
| Interradicular bone width | The width of the interradicular bone in the interradicular septum will be measured immediately before and after drilling is performed during surgery. Measurements will be taken using a UNC-15 periodontal probe and recorded in millimeters (mm). | Intraoperative (at time of surgery) |
| Dental implant stability | Implant stability will be assessed using the Osstell device, which uses resonance frequency analysis to calculate an Implant Stability Quotient (ISQ). ISQ values range from 1 to 100, with higher values indicating greater implant stability. | up to 4 months after dental implant placement |
| Measure | Description | Time Frame |
|---|---|---|
| Marginal Bone Level | Bone levels will be estimated on the labial, palatal, distal, and mesial surfaces of each implant using cone-beam computed tomography (CBCT). Measurements will be taken from a fixed reference point at the implant shoulder to the bone crest. All measurements will be recorded in millimeters (mm). | up to 7 months after the implantation |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Nayer Aboelsaad, Phd | Beirut Arab Univeristy | Study Chair |
| Rania Abdelaziz, Phd | Beirut Arab University | Study Director |
| Hani Arakji, Phd | Beirut Arab University | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Beirut Arab University | Beirut | Lebanon |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| Background | https://omx.journals.ekb.eg/article_140845_40c7deeba68c3279a9d3dffaed37c3fd.pdf |
| Label | URL |
|---|---|
| This article includes information about the success and stability achieved by using osseodensification technique | View source |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Conventional burs | Other | Preparation of dental implant site by the Conventional technique using Conventional burs that are subtractive |
|
| Bone density | Bone density will be measured in four regions around each dental implant: buccal, lingual, apical, and crestal. The mean grayscale value for each implant will be calculated based on these four areas. Bone density values will be obtained from cone-beam computed tomography (CBCT) and expressed in grayscale units. | up to 7 months after dental implant placement |
| This article includes information regarding stability of dental implants in narrow ridges when using conventional burs and osseodensifications burs | View source |
| This study includes information about marginal bone level and dental implant stability in conventional vs osseodensification techniques | View source |