This study is aiming to evaluate the retention of implant supported mandibular overdenture using two different clip materials namely polyoxymethylene (POM) and poly-ether-ether-ketone (PEEK) on PEEK bar at three-time intervals; immediately after placement, after 3 months and after 6 months.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| PEEK clip | Other | Clip for overdenture retention made from poly-ether-ether-ketone (PEEK) |
|
| Nylon clip | Other | Clip for overdenture retention made from nylon (C6H11NO)n |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| PEEK clip | Device | The overdentures were attached with PEEK clip . The retention of overdenture was assessed |
|
| Measure | Description | Time Frame |
|---|---|---|
| Overdenture retention assessed using Universal Testing Machine (Newton) | Denture resistance corresponding to vertical displacement force was obtained using a universal testing machine (INSTRON, United States) to measure retention. Each patient had his chin securely fixed on a support while seated upright. The attachment portion of the universal machine was adjusted in accordance with the device's bar being securely attached to the denture. The device gradually increased the vertical load by 10 mm per minute until the denture completely fell out of place. A tuck sound can be heard to indicate the load at the dislodgment point. Additionally, the force plot in the recorded computer software data exhibits an abrupt drop (Nexyge; Lloyd Instruments; MT-4.6). Each test was repeated five times to obtain five records, and the mean of these records was calculated. Testing was carried out on the mandibular overdenture after insertion, as well as at 3 and 6 months. | From enrollment and after 3 months and finally at the end of treatment at 6 months |
Not provided
Not provided
Inclusion Criteria:
Inclusion criteria:
Exclusion criteria:
bone density
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| MTI University | Cairo | Egypt |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Nylon clip | Device | The overdentures were attached with Nylon clip . The retention of overdenture was assessed |
|