Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Al-Azhar University | OTHER |
Not provided
Not provided
Not provided
Not provided
Endotracheal intubation is the de facto gold standard for airway management especially in neonatal and pediatric anesthesia .
An efficient neonatal airway management is challenging even in the most experienced hands and the prevalence of difficult intubation in pediatric anesthesia varied greatly on a wide range.
Neonatal intubation is a life-saving procedure, which requires skilled operator but still may cause direct tissue trauma and precipitate adverse reactions. However, intubation with videolaryngoscope (VL) requires less force than with a direct laryngoscope to minimize the possibility of these adverse events.
The recent Brazilian recommendations for management of pediatrics difficult airways included proper assessment, preparation, positioning, pre-oxygenation, minimizing trauma, maintenance of arterial oxygenation and the implementation of the advanced tools as VL, flexible intubating bronchoscopy, and supraglottic devices.
The recent British recommendations also advised for the use VL with an age-adapted standard blade as first choice for tracheal intubation and the use of a stylet to reinforce and preshape tracheal tubes in case of the use of hyperangulated VL blades .
Considering the recent interest in assessing the performance of various VLs in pediatric anesthesia, the C-MAC® (Karl Storz, Germany) VL with standard Miller blade sizes #0 and #1, is a widely used in neonates and infants for its provision of superior-quality glottis view in comparison to the McGrathTM MAC size #1 blade and direct laryngoscopy.
Presbyopia is defined as disordered eye adjustment function and affects middle aged people leading to difficult viewing close objects and is corrected with magnifying lens.
Earlier studies documented that presbyopic aged anesthetists find difficulty when trying to view a patient's larynx at a close distance and this difficulty is surely magnified on dealing with intubation of neonates and children
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Group A: (video laryngoscope Group) | Active Comparator | About 50 anesthetists in charge must be older than 40 years; each anesthetist had to manage at least 10 patients from both groups received endotracheal intubation (ETI) using the SL and VL group had intubated using the C-MAC® (Karl Storz, Germany) VL with the standard Miller blade and flexible Stylet (2 mm PORTEX® stylet; Smiths Medical International Ltd., UK) to strengthen the endotracheal tube (ETT) and adjust its curvature as C-shaped. The study outcomes included the frequency of successful intubation within 30 s (30-s SR) and the number of intubation attempts. . |
|
| Group B: (Standard laryngoscope Group) | Active Comparator | About 50 anesthetists in charge must be older than 40 years; each anesthetist had to manage at least 10 patients from both groups received endotracheal intubation (ETI) using the SL and VL group had intubated using the C-MAC® (Karl Storz, Germany) VL with the standard Miller blade and flexible Stylet (2 mm PORTEX® stylet; Smiths Medical International Ltd., UK) to strengthen the endotracheal tube (ETT) and adjust its curvature as C-shaped. The study outcomes included the frequency of successful intubation within 30 s (30-s SR) and the number of intubation attempts. . |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Video Laryngoscope | Procedure | Evaluation of the success rates (SR) of anesthetists aged ≥45 years for intubating neonates and infants using the C-MAC videolaryngoscope (VL) in comparison to the use of the standard laryngoscope (SL). |
| Measure | Description | Time Frame |
|---|---|---|
| the frequency of successful intubation | The frequency of the need for external laryngeal manipulation, head extension, or stylet curvature change to achieve intubation | 30 seconds |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Ahmed M.Elnagar, M.D | Al-Azhar University, Faculty of medicine for boys | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Al-Azhar University hospitals | Cairo | Egypt |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 39794694 | Derived | Abdalla AE, Eissa MM, Elbasyouny MR, Zomra MR, Elnaggar AM, Elsayed MM. The C-MAC video laryngoscope helps presbyopic anesthetists to overcome difficulty in neonatal and infantile intubation: a randomized controlled trial. BMC Anesthesiol. 2025 Jan 10;25(1):24. doi: 10.1186/s12871-024-02841-x. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D011305 | Presbyopia |
| ID | Term |
|---|---|
| D012030 | Refractive Errors |
| D005128 | Eye Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided