difficult intubation is high in the 0-1 year period. Video laryngoscopes improved intubation success rate when compared to direct laryngoscopy.
We compared the Airtraq, Glidescope, and c-mac video laryngoscopes during intubation of <1 year old children undergoing neurosurgery.
Aim: difficult intubation is high in the 0-1 year period. Video laryngoscopes improved intubation success rate when compared to direct laryngoscopy.
Methods: We enroll 20 patients age under 1 year old undergoing neurosurgery in this prospective randomized study. We compared the Airtraq, Glidescope, and c-mac video laryngoscopes during intubation of <1 year old children undergoing neurosurgery regarding intubation times and intubation success rates.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| intubation time airtraq | Active Comparator | inserting the device through the oral cavity till the visualization of the endotracheal tube passing through the vocal cords |
|
| intubation time glidescope | Active Comparator | inserting the device through the oral cavity till the visualization of the endotracheal tube passing through the vocal cords |
|
| intubation time c-mac | Active Comparator | inserting the device through the oral cavity till the visualization of the endotracheal tube passing through the vocal cords |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Airtraq | Device | airtraq video laryngoscope was used for intubation of the infant |
|
| Measure | Description | Time Frame |
|---|---|---|
| intubation time | device entering the oral cavity till visualization of the tube entering through the vocal cords | 40 seconds |
| Measure | Description | Time Frame |
|---|---|---|
| insertion time | device entering the oral cavity till the optimal visualization | 20 seconds |
Not provided
Inclusion Criteria:,
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Kocaeli University Medical Faculty | Kocaeli | Turkey (Türkiye) |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| glidescope | Device | glidescope video laryngoscope was used for intubation of the infant |
|
|
| c-mac | Device | c-mac video laryngoscope was used for intubation of the infant |
|
|