this study was done to evaluate clinically and radiographically four single piece inter-foraminal compressive implant connected via digitally designed co-cr milled bar with distal cantilever supporting mandibular overdenture. The evaluation will be done clinically and radiographically as following:
Six patients of age ranging from 40 to 60years (mean 50 years) were selected for this study from the out patients clinic, Prosthodontics department, Faculty of Dentistry, Mansoura University.
I) Preparation of the patient for implant placement:
II) Surgical phase :
III) Prosthetic phase:
IV) Evaluation:
Probing depth was measured for each implant using plastic probe and radiographic evaluation of the peri-implant marginal bone loss by using cone beam CT started for the patients from the delivery of final prosthesis (T0) and continue for 6 months (T6) and 12 month (T12) from insertion.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| compressive one piece implants with bar attachment | Experimental | All patients received 4 mandibular inter-foraminal single piece compressive implants, bar attachment connecting 4 implants was then cemented and complete mandibular overdenture was attached to bar via peek clips |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| compressive single piece dental implant | Procedure | 4 inter-foraminal single piece compressive dental implants were placed in the mandible via flapless protocol by the aid of stereolithographic surgical guide |
| Measure | Description | Time Frame |
|---|---|---|
| Peri-implant marginal bone loss | Peri-implant marginal bone loss was evaluated for each implant by the aid of cone beam CT scan | at time of insertion of prosthesis T(0), 6 months after insertion T(6), 12 months after insertion T(12) |
| Measure | Description | Time Frame |
|---|---|---|
| Peri-implant soft tissue health | probing depth was measured for each implant by the aid of plastic probe | at time of insertion of prosthesis T(0), 6 months after insertion T(6), 12 months after insertion T(12) |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Mohamed Shady, MD | Mansoura University Faculty of Dentistry, Prosthodontics department | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Mansoura University, Faculty of dentistry | Al Mansurah | Egypt |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
all patients recieved 4 inter-foraminal compressive single piece dental implants in the mandible, then milled bar was digitally constructed and cemented to 4 implants to support mandibular implant overdenture
Not provided
Not provided
Not provided
Not provided