The cochlear implant provides good auditory performance despite high inter-individual variability, but performance in noise remains limited. Modification of the coding strategies could improve these performances. A better characterization of the remaining neuronal population by looking for the charge integration efficiency (which depends on the duration and the amplitude of the electrical pulse) would allow an optimization of the settings by adapting either the duration or the amplitude of the pulse according to the quality of the remaining neuronal population.
The cochlear implant provides good auditory performance despite high inter-individual variability, but performance in noise remains limited. Modification of the coding strategies could improve these performances. Currently, the intensity perceived by the patient is coded by the duration and the amplitude of the electrical impulse but companies have different approaches and fix one of the two parameters for the setting of the processors. A better characterization of the remaining neuronal population by looking for the charge integration efficiency (which depends on the duration and the amplitude of the electrical pulse) would allow an optimization of the settings by adapting either the duration or the amplitude of the pulse according to the quality of the remaining neuronal population.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Cochlear implant users with Neuro Zti array | Experimental | Post-lingually cochlear implant users with 12 months of auditory experience Modifications of pulse parameters to determine the charge integration efficiency which is related with neuron survival population |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Cochlear implant (Oticon) stimulation parameter optimization | Other | The pulse amplitude and/or the pulse phase duration will be optimize to improve the intensity resolution of the cochlear implant which may benefit speech perception |
| Measure | Description | Time Frame |
|---|---|---|
| Calculate the charge integration efficiency along the electrodes | Charge integration efficiency will be determined for each electrode by noting the minimum and maximum loudness perceived by the patient as function of pulse phase duration and amplitude | 4 hours |
| Measure | Description | Time Frame |
|---|---|---|
| Questionnaire between Intensity discrimination and charge integration efficiency | 3 electrodes that span the range of charge integration efficiency values will be selected as test electrodes. Three intensities will be presented to the patient through the implant and it will be asked to the patient to determine which intensity is higher than the others. | 4 hours |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| David Bakhos, MD, PhD | Contact | +33 (0)218370523 | bakhos.david@gmail.com | |
| Elodie MOUSSET, MSc | Contact | +33 (0)247474665 | E.MOUSSET@chu-tours.fr |
| Name | Affiliation | Role |
|---|---|---|
| David Bakhos | University Hospital, Tours | Principal Investigator |
Not provided
Not provided
| ID | Term |
|---|---|
| D006319 | Hearing Loss, Sensorineural |
| D034381 | Hearing Loss |
| ID | Term |
|---|---|
| D006311 | Hearing Disorders |
| D004427 | Ear Diseases |
| D010038 | Otorhinolaryngologic Diseases |
| D012678 | Sensation Disorders |
Not provided
Not provided
| ID | Term |
|---|---|
| D003054 | Cochlear Implants |
| ID | Term |
|---|---|
| D058117 | Neural Prostheses |
| D058542 | Implantable Neurostimulators |
| D004567 | Electrodes, Implanted |
| D004566 | Electrodes |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| D009461 |
| Neurologic Manifestations |
| D009422 | Nervous System Diseases |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D055615 |
| Electrical Equipment and Supplies |
| D004864 | Equipment and Supplies |
| D019736 | Prostheses and Implants |
| D006310 | Hearing Aids |
| D012682 | Sensory Aids |