In the design of extracorporeal carbon dioxide removal (ECCO2R) combined with continuous renal replacement therapy (CRRT) equipment, in model of continuous veno-venous hemofiltration (CVVH) , the HCO3- concentration in the pre membrane lung blood is diluted by the replacement solution, and a decrease in HCO3- leads to a decrease in PCO2. On the other hand, in continuous veno-venous hemodialysis (CVVHD), HCO3- in post membrane blood will exchange interaction. The exchange results of HCO3- determine the impact of CVVHD on the CO2 removal efficiency of the ECCO2R combined CRRT system. This study aims to investigate the effects of CVVH and CVVHD on in vitro CO2 clearance efficiency.
In the design of extracorporeal carbon dioxide removal (ECCO2R) combined with continuous renal replacement therapy (CRRT) equipment, the pre dilution replacement solution for continuous veno-venous hemofiltration (CVVH) enters the extracorporeal bloodstream upstream of the membrane lung, so the HCO3- concentration in the pre membrane lung blood is diluted by the replacement solution. HCO3- and dissolved CO2 are in a dynamic and rapid equilibrium state, and a decrease in HCO3- leads to a decrease in PCO2. On the other hand, in continuous veno-venous hemodialysis (CVVHD), the blood after the membrane needs to undergo material exchange with the dialysate through a filter. The dialysate is usually HCO3- with normal plasma concentration, so HCO3- in post membrane blood will exchange interaction. The exchange results of HCO3- determine the impact of CVVHD on the CO2 removal efficiency of the ECCO2R combined CRRT system. This study aims to investigate the effects of CVVH and CVVHD on in vitro CO2 clearance efficiency.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Extracorporeal carbon dioxide removal combined with continuous renal replacement therapy | extracorporeal carbon dioxide removal combined with continuous veno-venous hemofiltration or continuous veno-venous hemodialysis.CVVH and CVVHD set-up: predilution 30 ml/kg/h, dialysate dose 30 ml/kg/h, ultrafiltration rate was equal to the total rate of substitution fluid infusion. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| continuous renal replacement therapy | Other | continuous veno-venous hemofiltration or continuous veno-venous hemodialysis set-up: predilution 30 ml/kg/h, dialysate dose 30 ml/kg/h, ultrafiltration rate was equal to the total rate of substitution fluid infusion |
| Measure | Description | Time Frame |
|---|---|---|
| extracorporeal CO2 removal rate | extracorporeal CO2 removal rate was calculated as the difference of total CO2 content before membrane lung and after hemofilter, and normalized to an inlet PCO2 of 45 mmHg | after 30min of continuous renal replacement therapy |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
using Extracorporeal carbon dioxide removal combined with continuous renal replacement therapy
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Ling Liu | Zhongda Hospital | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Ling Liu | Nanjing | Jiangsu | 210009 | China |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D000079664 | Continuous Renal Replacement Therapy |
| ID | Term |
|---|---|
| D017582 | Renal Replacement Therapy |
| D013812 | Therapeutics |
| D005112 | Extracorporeal Circulation |
| D013514 | Surgical Procedures, Operative |
Not provided
Not provided
Not provided
Not provided
Not provided