The most accurate way to determine intra-aortic BP is to obtain invasive measures by vascular catheterization, which is not possible to perform routinely during the regular follow-up of patients. However, in recent years, devices used to estimate central BP have been designed and approved for clinical use. These devices can determine aortic BP in a non-invasive way using various techniques and algorithms and offer a high degree of precision when compared to invasive measurements of intraaortic BP. On the other hand, certain characteristics specific to the different devices mean that the central BP values obtained may not be interchangeable. It is therefore important to determine the degree of agreement of central BP values obtained using commercially available devices.
This study aims to determine the degree of agreement between central BP measurements obtained using 4 devices commonly used to measure central blood pressure, i.e. Mobil-o-Graph NG (IEM, Germany), WatchBP Office (Microlife, Taiwan), Oscar 2 with SphygmoCor inside (SunTech, USA) and BP+ (Uscom, Australia). These four devices record the shape of the pulsatile wave and then derive the central BP using an algorithm. The main differences between these devices lie in this algorithm, or "transfer function,", which is unique to each and the calibration used. All use a brachial cuff to capture the pulse waveform and can easily be used in clinical practice.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Advanced CKD group | Experimental | Patients with eGFR < 30 ml/min/1.73m2 not on dialysis |
|
| Dialysis groups | Experimental | Patients on hemodialysis or peritoneal dialysis |
|
| Hypertension group | Experimental | Patients with BP > 135/85 mmHg or taking any antihypertensive medication with normal kidney function (eGFR > 60 ml/min/1.73m2) |
|
| Control group | Active Comparator | Normotensive patients without any antihypertensive drugs or chronic kidney disease |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Brachial and Central BP measurements with Mobil-o-Graph NG device (IEM), WatchBP Office device (Microlife), BP+ device (Uscom) and Oscar 2 with SphygmoCor inside device (SunTech) | Device | All participants will have three readings at 1-min interval after a 5-min seated rest with each device. The order in which each device will be tested is randomized. |
| Measure | Description | Time Frame |
|---|---|---|
| Central SBP difference | Differences in the central SBP measured by each device | at enrollment (time 0) |
| Measure | Description | Time Frame |
|---|---|---|
| Brachial SBP difference | Differences in the brachial cuff SBP measured by each device | at enrollment (time 0) |
| Central DBP difference | Differences in the central DBP measured by each device |
Not provided
Inclusion Criteria:
- Age 18-80 years old
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Hôpital du Sacré-Coeur de Montréal | Montreal | Quebec | H4J1C5 | Canada |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| at enrollment (time 0) |
| Brachial DBP difference | Differences in the brachial cuff DBP measured by each device | at enrollment (time 0) |
| ID | Term |
|---|---|
| D006973 | Hypertension |
| D051436 | Renal Insufficiency, Chronic |
| ID | Term |
|---|---|
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
| D051437 | Renal Insufficiency |
| D007674 | Kidney Diseases |
| D014570 | Urologic Diseases |
| D052776 | Female Urogenital Diseases |
| D005261 | Female Urogenital Diseases and Pregnancy Complications |
| D000091642 | Urogenital Diseases |
| D052801 | Male Urogenital Diseases |
| D002908 | Chronic Disease |
| D020969 | Disease Attributes |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
| ID | Term |
|---|---|
| D019722 | Sphygmomanometers |
| ID | Term |
|---|---|
| D019719 | Diagnostic Equipment |
| D004864 | Equipment and Supplies |
Not provided
Not provided