Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Nine patients (five males and four females) were included in this study who had long-term (10-15 years) of long-span rigid mandibular fixed prostheses that may have led to radiographic changes around the supporting teeth. The treatment plans included the removal of the long-span fixed rigid prostheses followed by restoring the patients with segmented implant-supported prostheses. In order to digitally measure the mandibular flexure, reference markers were adhered to the prostheses, and intraoral scans were obtained before and after splitting the preexisting prostheses at the minimum and maximum mouth opening. The distances between the markers were measured, and mandibular flexure was calculated by subtracting the distance between the markers during the maximum mouth opening from the minimum mouth opening. An independent sample T-test was used to compare mandibular flexure before and after splitting the long-span fixed prostheses.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Mandibular flexure before sectioning of full arch fixed prosthesis | |||
| Mandibular flexure after sectioning of full arch fixed prosthesis |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Sectioning of the full arch mandibular fixed prosthesis | Procedure | The one unit full arch fixed prosthesis is sectioned at the midline into two pieces |
|
| Measure | Description | Time Frame |
|---|---|---|
| change in mandibular flexure | change in mandibular flexure before and after splitting of the fixed full arch prosthesis | immediately after the splitting of the full arch fixed prosthesis. |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
All had the entire mandibular natural dentition (6-8 abutments) splinted with a single-unit metal-ceramic (long-span fixed prosthesis). All of them suffered from different negative consequences of their one-piece fixed restorations. The retrospective collection of the patient's data was tabulated and analyzed. Nine patients were included in this study. Five males and four females, with an age range of 50-76 years were enrolled in this study.
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Future University in Egypt | Cairo | 111111 | Egypt |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 37697386 | Derived | El Charkawi H, Nassar HI, Abdelaziz MS. Retrospective digital study of mandibular flexure in patients with long-span fixed restorations supported by natural teeth. BMC Res Notes. 2023 Sep 11;16(1):203. doi: 10.1186/s13104-023-06486-w. |
Not provided
Not provided
study protocol, raw data,statistics
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D011475 | Prosthesis Failure |
| ID | Term |
|---|---|
| D011183 | Postoperative Complications |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
Not provided
Not provided
Not provided