The present study aimed to investigate and compare the acute effect of local vibration (63 Hz vs 42 Hz frequencies) on the biceps brachii muscles on the elbow joint position sense (JPS) in healthy young men. Forty-five healthy young men aged 19 to 30 years were enrolled in the study. The participants were randomly assigned to receive either 63 Hz (n=15) or 42 Hz (n=15) or sham vibration (control group) (n=15). Participants in the experimental group received five bouts of 1-minute of each vibration exposure localized to the biceps brachii muscle, with a 1-minute rest between the bouts. Active elbow joint position error (in degrees) was selected as an outcome measure to assess elbow JPS. To measure active elbow joint position error, the subject was made to sit on the chair with eyes closed and shoulders in 0 degree of abduction and elbows fully extended. The examiner passively moved the elbow to 90 degrees of flexion (target position) and maintained it for 10 seconds. The subject was requested to memorize the target position. The subject was asked to actively flex the elbow to the target position from the initial starting position (elbow fully extended) and hold it for 5 seconds. Three trials were conducted, with a 30-second rest given between each trial. The target and reproduced angles in each trial were measured using a standard plastic goniometer. The difference between the target and reproduced angles in each trial was calculated to determine active elbow joint position error. Measurements were taken at baseline and immediately after the vibration protocol.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| 63 Hz vibration group | Experimental | Vibration of 63 Hz frequency was applied. |
|
| 42 Hz vibration group | Active Comparator | Vibration of 42 Hz frequency was applied. |
|
| Sham vibration group | Sham Comparator | No actual vibration was applied. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| 63 Hz Vibration | Other | Vibrations of 63 Hz were applied with handheld vibration device. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Active elbow joint position error | Participants were asked to actively reproduce a target position of the elbow joint. | 1 day |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Masood Khan, M.P.Th | King Saud University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| King Saud University | Riyadh | 11433 | Saudi Arabia |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| 42 Hz Vibration | Other | Vibrations of 42 Hz were applied with handheld vibration device. |
|
| Sham vibration | Other | Handheld device was applied to the participants without any vibrations. |
|