Type 1 Diabetes (T1D) is the most common form of diabetes affecting children, requiring lifelong administration of insulin to prevent complications. The incidence of T1D has increased more among African Americans, Hispanics, and Asian/Pacific Islanders compared to Caucasian youths in the past two decades. Despite advances in insulin delivery systems, fewer black and Hispanic children compared to white children with T1D use insulin pumps. Therefore, most minority children with T1D in urban areas require multiple daily injections (MDI) of insulin which may put them at increased risk of poor glycemic control. Although several factors contribute to worsening glycemic control in adolescents with T1D, studies have shown that missing doses of insulin at mealtimes is a major factor.
Adolescents with T1D who use MDI with a basal-bolus regimen use formulas to calculate insulin doses that involve a four-step process. The complexity of determining insulin doses contributes to inaccuracies in both timing of doses and amount of insulin given, both of which can lead to hyperglycemia and hypoglycemia.
The InPenâ„¢ Smart Insulin Pen System (Medtronics) was approved by the FDA for children of all ages with T1D in June 2020. The InPen is a Bluetooth-enabled smart insulin pen that helps with management of insulin dosing and tracking via capture of rapid-acting insulin doses and tracking of insulin in the body through the use of its companion app (free on Apple iOS and Android). The app includes a bolus calculator, which can lead to more accurate insulin dosing, which may improve glycemic control.
The specific benefits of using the InPen include the following: simplifying insulin dose calculations, administering more accurate insulin doses, tracking insulin doses to help prevent hypoglycemia, providing reminders to administer insulin, and storing data in the InPen App that can be easily shared with diabetes healthcare teams to assist with adjusting insulin doses.
The goal of this study is to determine if use of the InPen will improve glycemic control and diabetes numeracy in adolescents with uncontrolled T1D living in urban areas.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| InPen | Patients who will begin using the InPen device as per standard of care |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| InPen Insulin Pen | Device | The InPen is a reusable smart insulin pen for people living with diabetes. The device uses Bluetooth technology to send dose information to a mobile application. The InPen can be used to deliver insulin, help calculate insulin doses, and estimate carbohydrates for meals |
| Measure | Description | Time Frame |
|---|---|---|
| Change in Hemoglobin A1c (HbA1c) | Change in mean hemoglobin A1c (HbA1c) among patients from baseline to 12- and 24 weeks after using the InPen device in diabetes management plan. | Baseline to 12 and 24 weeks (End of study) |
| Measure | Description | Time Frame |
|---|---|---|
| Change in Diabetes Numeracy Test (DNT-14) | Assessment test designed to investigate numeracy skills in patients with diabetes | Baseline and 24 weeks (end of study) |
| Clinical Evaluation of Treatment |
Not provided
Inclusion Criteria:
Patients from 13-21 years of age (inclusive) at the time of enrollment.
Patients diagnosed with type 1 diabetes for more than 6 months.
Patients with uncontrolled T1D as defined by an elevated HbA1c > 8% within the last 3 months prior to the start of the study.
Patients using multiple daily injections of insulin (MDI); basal- bolus regimen requiring three or more injections per day.
Completion of basic diabetes education program within first year of diagnosis including management of hyperglycemia and hypoglycemia.
Patients not actively using InPen (including discontinuation of the InPen for at least 12 weeks).
Exclusion Criteria:
Not provided
Not provided
Patients aged 13-21 years of age with Type 1 Diabetes who will be initiating treatment with the InPen insulin pen device
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Wayne State University | Detroit | Michigan | 48221 | United States |
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| ICF | No | No | Yes | Informed Consent Form | May 18, 2022 | Jul 25, 2022 | ICF_000.pdf |
Not provided
| ID | Term |
|---|---|
| D003922 | Diabetes Mellitus, Type 1 |
| ID | Term |
|---|---|
| D003920 | Diabetes Mellitus |
| D044882 | Glucose Metabolism Disorders |
| D008659 | Metabolic Diseases |
| D009750 | Nutritional and Metabolic Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
|
Questionnaire to assess usability, comfort with, and usefulness of the InPen and its app.
| 24 weeks (end of study) |
| D004700 | Endocrine System Diseases |
| D001327 | Autoimmune Diseases |
| D007154 | Immune System Diseases |