The project focuses on the possibility of detecting blood loss using electrical impedance tomography. Based on previous animal experiments, it was found that the bolus of saline significantly affects the signal of chest bioimpedance. It is assumed that blood loss of a similar volume will cause a similar signal change with the opposite trend. The aim of this project is to determine whether there is a significant change in the thoracic electrical impedance tomography signal when blood loss is caused by voluntary blood donation.
Electrical impedance tomography is a bedside method of ventilation monitoring. The bioimpedance of the tissue depends, among other things, on its blood content. The area of the chest and especially the lungs is a heavily perfused tissue, which also serves as one of the reservoirs of blood in case of blood loss. It is therefore possible that blood loss will be visible on chest bioimpedance relatively soon.
The study will be performed on voluntary blood donors. Blood loss of 450 mL will be caused by the collection of donated blood. During blood collection at the transfusion department, thoracic bioimpedance will be measured using electrical impedance tomography. The resulting signal change will then be analyzed to determine the possibility of detecting and measuring blood loss using electrical impedance tomography.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Voluntary blood donors | Experimental | Voluntary blood donors undergoing standard blood donation while measuring electrical impedance of the chest . |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Electrical impedance tomography measurement | Device | During standard blood donation, donors' chest bioimpedance will be measured using electrical impedance tomography. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Change in chest electrical impedance due to blood loss. | A change in the electrical impedance of the chest of a voluntary blood donor caused by a blood donation. | Time frame of one voluntary blood donation process (15 min) |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Vaclav Ort, M.Eng. | Contact | +420 731 577 649 | ortvacla@fbmi.cvut.cz |
| Name | Affiliation | Role |
|---|---|---|
| Vaclav Ort, M.Eng. | Czech Technical University in Prague, Fac. of Biomedical Engineering | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Czech Technical University, Faculty of Biomedical Engineering | Recruiting | Kladno | 272 01 | Czechia |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D006470 | Hemorrhage |
| ID | Term |
|---|---|
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
Single group assignment. Approx 10-15 voluntary blood donors.
Not provided
Not provided
Not provided
Not provided
| Czech technical university in Prague, Facutly of biomedical engineering | Recruiting | Kladno | 27201 | Czechia |
|