The investigators have developed a system based on a pulse oximeter, a tablet, and an algorithm running on the tablet that analyzes the pulse oximeter waveform.
The algorithm that runs on this system should be able to accurately keep track of blood loss during blood donation. The investigators will compare the algorithm with the blood loss tracked by a device called a flow meter.
The algorithm that runs on this system should be able to accurately keep track of stroke volume changes. The investigators will compare the algorithm with the stroke volume changes tracked by a device called a CCNexfin.
The algorithm that runs on this system should work whether it's in place for the whole blood donation, or if it's placed after the blood donation has started. The investigators will use two pulse oximeters for the system on each hand and compare one that is used for the whole blood donation versus one that is not used for the whole blood donation.
Hypothesis: p-values for testing the hypothesis of no correlation against the alternative that there is a nonzero correlation for each subject will be calculated. The minimum average power correlation, alpha = 0.05, will be used. Correlation will be made (CRI trend during 550ml blood volume removal) using pre and post blood draw data.
Specific Aims: These data will be submitted to the FDA with the following claims: The CRI algorithm
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Blood donors | Healthy adult volunteers donating blood |
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Change in Intravascular volume | The CRI algorithm is intended to display the trend of intravascular volume changes. This is measured Day One. | Day One |
| Change in Stroke volume | The CRI algorithm is intended to display the trend of stroke volume changes. This is measured Day One. | Day One |
| CRI trend | The CRI algorithm is intended to not require calibration, or being placed, during normal physiological conditions. This is measured Day One. | Day One |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Healthy adult volunteers donating blood
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Steve Moulton, MD | University of Colorado, Denver | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Children's Hospital Colorado's Blood Donation Center | Aurora | Colorado | 80045 | United States |
Not provided
| ID | Term |
|---|---|
| D006470 | Hemorrhage |
| ID | Term |
|---|---|
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
Not provided
Not provided
Not provided