Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Background and Aim. The new and advanced hybrid closed loop (AHCL) system MiniMed 780G automatically adjusts basal insulin delivery in addition to automated bolus corrections, based on continuous glucose monitoring (CGM) readings, to offer protection against both hyperglycemia and hypoglycemia.
The objective of this study is to evaluate whether a simplified approach for patients' follow up using preset of pump settings and a simplified meal announcement, followed by minimal interaction can achieve similar glycemic control of AHCL system MiniMed 780G with Guardian Sensor 4 than a regular protocol that is currently used in adolescents with Type 1 Diabetes (T1D).
Methods. This study is Randomized Clinical Trial, two arm, single-center, clinical investigation in subjects with type 1 diabetes on AHCL insulin pump in a period of 3 months. A total of 34 individuals (age 12-18 years) will be enrolled to reach 30 individuals who will complete the 3 months study. Participants will be randomized in two groups: Group 1, Regular Clinical Protocol, 17 participants and Group 2, Simplified Clinical Protocol, 17 participants.
All patients will be recruited during the regular clinic visits to the outpatient Endocrine Clinics at Sidra Medicine in Doha. Patients will be chosen on a first-come first-served basis. Inclusion criteria: Clinical diagnosis of type 1 diabetes, , Age 12-18 years, Basal Bolus therapy >8.0 units per day. Exclusion criteria: Diabetic Ketoacidosis (DKA) in the 6 months prior to screening visit. The initiation protocol consists of four stages: HCL system compatibility assessment, HCL system training, Manual Mode Start and Auto Mode start. Patients will have 7 visits in a period of 3 months after initiation of insulin pump therapy.
Pump initiation: Group 1, Finetune ICR, Target 100 or 110 mg/dl and AIT: 2-3 hour and Group 2, Carb Ratio by formula 360 / TDD, ICR 8-10 (TDD 40-60), ICR 5-7 (TDD >60), Target 100 mg/dl, AIT: 2 hours with fixed meals Results. No group difference in Time in Range (TIR) (70-180mg/dl) > 70% and HbA1c < 7.5% in a period of 3 months after initiation of AHCL.
Conclusion. Conclusions will be drawn on completion of the study and evaluation of the results.
This study is Randomized Clinical Trial, two arm, single-center, clinical investigation in subjects with type 1 diabetes on AHCL insulin pump in a period of 3 months.
A total of 34 individuals (age 12-18 years) will be enrolled to reach 30 individuals who will complete the 3 months study.
Participants will be randomized in two groups:
Group 1, Regular Clinical Protocol, 17 participants
Group 2, Simplified Clinical Protocol, 17 participants Intervention Description
Intervention in Group 2, Simplified protocol.
Insulin Carb Ratio (ICR) by formula 360 / Total Daily Dose (TDD)
Target 100 mg/dl
Active Insulin Time (AIT): 2 hours
Meals: Thee sets of meal set of meals announcement carbs calculated by the following formula:
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Group 1, Regular Protocol | Active Comparator | Participants will bolus (insulin), based on carbohydrate content in each meal |
|
| Group 2, Simplified protocol | Experimental | Participants will bolus (insulin), based on three sets of meal set of meals announcement |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Regular Protocol with advanced carbohydrate counting | Procedure |
|
| Measure | Description | Time Frame |
|---|---|---|
| Time in Range( 70-180 mg/dl) | Group change in the third month of AHCL use | Third month |
| Measure | Description | Time Frame |
|---|---|---|
| HbA1c | Change between groups | 3 months |
| Average Sensor Glucose | Change between groups | 3 months |
| Measure | Description | Time Frame |
|---|---|---|
| Sensor wear | % of sensor wear, change between each groups | 3 months |
| Auto Mode - SmartGuard | % of Automode-SmartGuard, change between groups |
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Goran Petrovski, PhD | Sidra Medicine | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Sidra Medicine | Doha | Qa | 26999 | Qatar |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 31876178 | Background | Petrovski G, Al Khalaf F, Campbell J, Fisher H, Umer F, Hussain K. From Multiple Daily Injections to Hybrid Closed-Loop System in Ten Days, Utilizing a Structured Initiation Protocol. J Diabetes Sci Technol. 2020 May;14(3):689-690. doi: 10.1177/1932296819895509. Epub 2019 Dec 26. No abstract available. | |
| 33453783 | Result |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
This study is Randomized Clinical Trial, two arm, single-center, clinical investigation in subjects with type 1 diabetes on AHCL insulin pump in a period of 3 months.
Participants will be randomized in two groups:
Not provided
Not provided
Eligible subjects shall be randomly assigned to Group 1 or Group 2 in a 1:1 ratio using a computer-generated randomization scheme developed by the data manager.
|
| Simplified Protocol with fixed carbohydrate content | Procedure |
|
|
| Time Bellow Range (<70 mg/dl, <54 mg/dl) | Change between groups | 3 months |
| Time Above Range (>180 mg/dl) | Change between groups | 3 months |
| Diabetic Ketoacidosis | Number of events in each group | 3 months |
| Severe Hypoglycemia | Number of events in each group | 3 months |
| 3 months |
| Total Daily Insulin | % of Automode, Change between each groups | 3 months |
| Bergenstal RM, Nimri R, Beck RW, Criego A, Laffel L, Schatz D, Battelino T, Danne T, Weinzimer SA, Sibayan J, Johnson ML, Bailey RJ, Calhoun P, Carlson A, Isganaitis E, Bello R, Albanese-O'Neill A, Dovc K, Biester T, Weyman K, Hood K, Phillip M; FLAIR Study Group. A comparison of two hybrid closed-loop systems in adolescents and young adults with type 1 diabetes (FLAIR): a multicentre, randomised, crossover trial. Lancet. 2021 Jan 16;397(10270):208-219. doi: 10.1016/S0140-6736(20)32514-9. |
| 33784187 | Result | Beato-Vibora PI, Gallego-Gamero F, Ambrojo-Lopez A, Gil-Poch E, Martin-Romo I, Arroyo-Diez FJ. Rapid Improvement in Time in Range After the Implementation of an Advanced Hybrid Closed-Loop System in Adolescents and Adults with Type 1 Diabetes. Diabetes Technol Ther. 2021 Sep;23(9):609-615. doi: 10.1089/dia.2021.0037. Epub 2021 Apr 20. |
| 31264889 | Result | Lee MH, Vogrin S, Paldus B, Jones HM, Obeyesekere V, Sims C, Wyatt SA, Ward GM, McAuley SA, MacIsaac RJ, Krishnamurthy B, Sundararajan V, Jenkins AJ, O'Neal DN. Glucose Control in Adults with Type 1 Diabetes Using a Medtronic Prototype Enhanced-Hybrid Closed-Loop System: A Feasibility Study. Diabetes Technol Ther. 2019 Sep;21(9):499-506. doi: 10.1089/dia.2019.0120. Epub 2019 Jul 2. |
| 30620641 | Result | Paldus B, Lee MH, Jones HM, McAuley SA, Horsburgh JC, Roem KL, Ward GM, MacIsaac RJ, Cohen N, Colman PG, Jenkins AJ, O'Neal DN. Glucose Control Using a Standard Versus an Enhanced Hybrid Closed Loop System: A Randomized Crossover Study. Diabetes Technol Ther. 2019 Jan;21(1):56-58. doi: 10.1089/dia.2018.0279. |
| 31953687 | Result | Petrovski G, Al Khalaf F, Campbell J, Fisher H, Umer F, Hussain K. 10-Day structured initiation protocol from multiple daily injection to hybrid closed-loop system in children and adolescents with type 1 diabetes. Acta Diabetol. 2020 Jun;57(6):681-687. doi: 10.1007/s00592-019-01472-w. Epub 2020 Jan 17. |
| 38377327 | Derived | Petrovski G, Campbell J, Pasha M, Hussain K, Khalifa A, Umer F, Almajaly D, Hamdar M, Heuvel TVD, Edd SN. Twelve-Month Follow-up from a Randomized Controlled Trial of Simplified Meal Announcement Versus Precise Carbohydrate Counting in Adolescents with Type 1 Diabetes Using the MiniMed 780G Advanced Hybrid Closed-Loop System. Diabetes Technol Ther. 2024 Mar;26(S3):76-83. doi: 10.1089/dia.2023.0429. |