Work-related musculoskeletal disorders (WRMSD) among sonographers/radiographers are prevalent in the healthcare industry. This pilot study will evaluate the use of a robotic assisted ultrasonography system (ROBUST) against the conventional abdominal ultrasound scanning procedure. The ROBUST will be developed to provide 6 degrees of freedom to allow radiographers to perform abdominal scanning without having to reach over patients.
10 sonographers with at least 5 years of experience will be recruited from SGH and SKH, to perform abdominal ultrasound scans on healthy volunteers. Each sonographer will be randomly assigned to scan a volunteer using conventional abdominal ultrasound scanning procedure and with ROBUST respectively. The study will be done in 2 phases, separated by at least a 1-month interval between scans.
Phase 1: Scanning of volunteer using conventional abdominal ultrasound scanning procedure.
Phase 2: Scanning of volunteer using ROBUST. Outcome measures will include ultrasound image quality, sonographer feedback and comfort level as well as satisfaction feedback from healthy volunteers. A panel of 4 reviewers, consisting of 2 radiologists and 2 senior radiographers will be invited to grade the images, using a 3-point Likert scale. The duration of each scanning will be recorded. The comfort level reported by sonographers will be assessed using the SGH Comfort Level Survey. In addition, the comfort level of healthy volunteers will also be assessed using a satisfaction questionnaire.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Comparison of quality of ultrasound image for manual scanning and robot scanning | During the scan | |
| Kinematic data, Range of Motion from motion capture system | During the scan | |
| Muscle activation from EMG data | During the scan | |
| Static bilateral grip strength | Immediately before the scan and immediately after the scan | |
| Questionnaire on comfort level from sonographers | immediately after the scan | |
| Questionnaire on Satisfaction level from healthy volunteers | immediately after the scan |
Not provided
Not provided
Inclusion Criteria:
Sonographer:
-Experienced sonographers/ radiographers with more than 5 years of experience
Healthy volunteer:
Exclusion Criteria:
Sonographer:
-Participating sonographers with previously reported work-related or non-work related musculoskeletal discomfort or injury
Healthy volunteer:
-Pregnancy
Not provided
Not provided
10 sonographers from SGH or SKH and 10 healthy volunteers.
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Singapore General Hospital | Singapore | 169608 | Singapore | |||
| Sengkang General Hospital |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Singapore |
| 544886 |
| Singapore |