Epidural anaesthesia involves the administration of numbing medication (local anaesthetics) close to the spinal canal, and is regarded as the best method for providing pain relief during labour and childbirth. The use of ultrasound to guide epidural insertion and placement has been shown to improve pain relief and reduce the risk of complications.
However, after identifying the desired needle insertion site via ultrasound, current practice involves demarcating the insertion site using marker pens, which is time-consuming, inaccurate, and may be inadvertently removed by skin sterilisation. Furthermore, the desired needle angulation determined by ultrasound cannot be accurately measured and maintained during the epidural procedure. Both issues limit the benefits of using ultrasound to guide the epidural procedure.
To address these issues, the investigators developed a Position and Angular Marking System (PAMS) that attaches on to the ultrasound probe. When the desired insertion site is identified by ultrasound, the doctor gently presses PAMS into the patient's back to create skin indentations demarcating the needle insertion point. These indentations are not affected by skin sterilisation, and may improve accuracy and reduce the time taken to perform the epidural procedure. Next, the angle between the ultrasound probe and the patient's back can be measured using PAMS, and this angle can be maintained using a needle guide during the epidural procedure.
The purpose of this randomised study is to evaluate the usability of PAMS and to identify areas for further improvement.
This study will involve up to 10 healthy simulated patients, and up to 30 volunteer ultrasound operators. After undergoing a standardised training session with a mannequin, the ultrasound operators will be randomly assigned to perform skin marking on the simulated patients as though they are performing an ultrasound-guided epidural anaesthesia procedure (no needle puncture will be made) using either PAMS, or standard clinical practice with marker pens. After completing the procedure, the ultrasound operators will cross over and perform the procedure again using either PAMS or standard clinical practice with marker pens.
Both the ultrasound operators and simulated patients will be asked to complete satisfaction and usability surveys regarding their experience with the procedures.
The volunteer ultrasound operators are women's anaesthesiologists trained in the use of ultrasound-guided neuraxial procedures.
Simulated patients are healthy volunteers from other departments, without spine abnormalities.
The ultrasound operators will be asked to complete a questionnaire regarding your prior experience with neuraxial ultrasonography and undergo structured training on the use of PAMS using a mannequin. Next, they will be asked to perform the following two procedures (the order at which they will perform the procedures will be randomised):
Ultrasound scan using PAMS
Ultrasound scan without PAMS (standard clinical practice)
Both procedures are non-invasive (i.e. no skin punctures will be made). No follow up is required for this study.
No new research medications are involved in this study.
Additionally, video recordings may be made of the procedures. Any video or ultrasound images obtained during the course of this study will be stored and analysed only for the purposes of this study for a period not exceeding 7 years, and will be destroyed after completion of the study. Technical data such as the scanning duration and success rate will also be documented.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Standard clinical practice | Active Comparator |
|
|
| Position and Angle Marking System (PAMS) | Experimental |
|
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Position and Angle Marking System | Device | Position and Angular Marking System (PAMS) attaches on to the ultrasound probe. When the desired insertion site is identified by ultrasound, the doctor gently presses PAMS into the patient's back to create skin indentations demarcating the needle insertion point. These indentations are not affected by skin sterilisation, and may improve accuracy and reduce the time taken to perform the epidural procedure. Next, the angle between the ultrasound probe and the patient's back can be measured using PAMS, and this angle can be maintained using a needle guide during the epidural procedure. |
| Measure | Description | Time Frame |
|---|---|---|
| Satisfaction survey of simulated patients and operators | Satisfaction and feedback regarding the respective procedures | Immediately after performing the procedure |
| Measure | Description | Time Frame |
|---|---|---|
| Time taken to perform procedure | Comparison of time taken to perform the interventional procedure (PAMS), versus standard clinical practice (control) | Immediately after performing the procedure |
Not provided
Ultrasound operators
Inclusion Criteria:
Exclusion Criteria:
Simulated patients
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Hon Sen Tan, MD | Contact | +65 63947107 | paul.tan.hs@singhealth.com.sg | |
| Ban Leong Sng, MBBS | Contact | +65 63941077 | sng.ban.leong@singhealth.com.sg |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| KK Women's and Children's Hospital | Recruiting | Singapore | 128038 | Singapore |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 31045638 | Background | Tan HS, Sng BL, Sia ATH. Reducing breakthrough pain during labour epidural analgesia: an update. Curr Opin Anaesthesiol. 2019 Jun;32(3):307-314. doi: 10.1097/ACO.0000000000000713. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D056888 | Patient Positioning |
| ID | Term |
|---|---|
| D005791 | Patient Care |
| D013812 | Therapeutics |
| D006296 | Health Services |
| D005159 | Health Care Facilities Workforce and Services |
Not provided
Not provided
The ultrasound operators will be randomised to perform either
After completion of the first procedure, the ultrasound operators will then crossover and perform the other procedure.
Not provided
Not provided
No masking involved.
Not provided
|
|
| Standard clinical practice | Device | When the desired insertion site is identified by ultrasound, the doctor demarcate the needle insertion point using marker pens. |
|