| Name | Class |
|---|---|
| Na Homolce Hospital | OTHER |
Not provided
Not provided
Not provided
Not provided
In sudden cardiac arrest patients with return of spontaneous circulation, brain damage is one of the main determinants of short-term mortality and poor prognosis (CPC 3-5). It is important to properly select group of patients in whom treatment is futile. According to current guidelines, multimodal approach is recommended. Optic nerve sheath diameter measured by ultrasound is non-invasive, fast, low-cost and readily available bed-side method, but evidence for its use as neuroprognostication modality is limited to only few small studies. The aim of this study is to evaluate validity of ONSD as neuroprognostication method at larger cohort of patients, compare it with other established methods and compare ultrasound and CT measurement of ONSD.
Additional relevant MeSH terms:
cardiac arrest, cardiovascular diseases, optic nerve sheath diameter.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Optic nerve sheath diameter measured by transorbital ultrasound | Procedure | Optic nerve sheath diameter measured 3 mm behind eyeball. For every eyeball 2 measurements in axial and 2 measurements in sagital projections are performed. Summary value for every eyeball is arithmetic mean from these 4 measurements. |
| Measure | Description | Time Frame |
|---|---|---|
| Value of ONSD for short-term neurological outcome prediction | Assessment of the correlation between the optic nerve sheath diameter measured by transorbital ultrasonography and neurological outcome of patients (quantified by the CPC scale) after out of hospital cardiac arrest with subsequent ROSC | 30 days |
| Value of ONSD for short-term mortality prediction | Assessment of the correlation between optic nerve sheath diameter measured by transorbital ultrasonography and mortality during a 30-day follow-up. | 30 days |
| Measure | Description | Time Frame |
|---|---|---|
| Comparison of ONSD and electrophysiologic modalities for neurological outcome prediction | Assessment of the correlation between the optic nerve sheath diameter measured by transorbital ultrasonography and negative prognostic markers obtained by somatosensory evoked potentials examination and EEG in patients remaining in a coma even after the end of therapeutic hypothermia and sedation. | 96 hours |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Male and female patients after cardiac arrest with subsequent ROSC, 18 years of age and older
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Štefan Volovár, MUDr. | University hospital Plzen | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University Hospital Plzen | Pilsen | Czechia |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D006323 | Heart Arrest |
| ID | Term |
|---|---|
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
microRNA, copeptine and NSE sampling
| Comparison of ONSD measurements by ultrasonography and computed tomography | Assessment of accuracy of the optic nerve sheath diameter measured by ultrasonography compared to CT measurement performed 48 ± 12 hours after achievment of ROSC. | 48 hours |
| Correlation between ONSD and fundoscopic signs of papillary edema | Assessment of the correlation between the optic nerve sheath diameter measured by transorbital ultrasonography and grade of optic nerve papillary edema quantified by the Frisen scale on fundoscopic examination performed 48 ± 12 hours after achievment of ROSC. | 48 hours |
| Correlation between ONSD and thickness of retinal nerve fibers measured by OCT | Assessment of the correlation between the optic nerve sheath diameter measured by transorbital ultrasonography and thickness of retinal nerve fibers measured by optical coherence tomography at time intervals of 1, 3 and 5 months after achievment of ROSC. | 5 months |
| Effect of blood carbon dioxide on ONSD | Assessment of the correlation between the optic nerve sheath diameter measured by transorbital ultrasonography and paCO2 and ETCO2 values at the time of measurement. | 72 hours |
| Value of ONSD for long-term neurological outcome and mortality | Assessment of the correlation between the optic nerve sheath diameter measured by transorbital ultrasonography and mortality and neurological outcome of patients (quantified by the CPC scale) at 6 months after ROSC. | 6 months |
| Correlation between blood NSE, copeptin and selected RNAs | Assessment of the correlation between blood NSE, copeptin and selected micro-RNAs measured at defined time intervals from ROSC, to neurological outcome prediction in patients after out of hospital cardiac arrest with subsequent ROSC. | 6 months |