Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| United States Department of Defense | FED |
Not provided
Not provided
Not provided
Not provided
The study involves the 'first-in-human' evaluation of a novel optical sensor which uses near-infrared spectroscopy (NIRS) technology to assess oxygenation and hemodynamics of the injured spinal cord. The NIRS sensor is laid on top of the dura, at the site of the SCI, and emits near-infrared light signals into the cord to measure tissue oxygenation and tissue hemodynamics in real-time. Our testing of this novel NIRS sensor in patients with acute SCI represents the first step in translating this technology for human use.
This single-center, prospective observational study will enroll 10 patients admitted to Vancouver General Hospital (VGH) for treatment of an acute traumatic spine injury.
Promising preclinical data demonstrates that the oxygenation and hemodynamic measures of our Near Infra-Red Spectroscopy (NIRS) system closely match the invasive intraparenchymal measures obtained within the injured spinal cord. Further, the NIRS sensor is responsive and reflective of systemic hemodynamic changes. This clinical protocol represents the first application of this novel NIRS sensor in human SCI. Following operative decompression of the spinal cord via a posterior approach, the NIRS sensor will be placed over the dura for 7 days to monitor spinal cord oxygenation and tissue hemodynamics. Patients will be followed for 6 months and data collection for safety, feasibly and efficacy of the NIRS System.
The specific aims of this project are to:
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Arm 1 | Experimental | NIRS monitoring of spinal cord oxygenation and hemodynamics |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Near Infra-Red Spectroscopy (NIRS) Sensor | Device | The NIRS sensor is laid on top of the dura, at the site of the SCI, and emits near-infrared light signals into the cord to measure tissue oxygenation and tissue hemodynamics in real-time. |
| Measure | Description | Time Frame |
|---|---|---|
| Feasibility Assessment - Overall | Study specific questionnaire will collected data on the the ease of sensor application, NIRS monitoring and sensor removal is recorded with this form. Series of questions requiring the assessment of the NIRS system using yes/no and 10-point scoring scale | Day 7 |
| Feasibility Assessment: Sensor Application | Study specific form will be used record data associated with application of the NIRS sensor, such as the laminectomy and instrumentation data, location of the sensor and ease of application (score out of 10). | Day 1 |
| Feasibility Assessment: Sensor Removal | Study specific form will be used to record the condition of the sensor and participants' experience (score out of 10) at the time of sensor removal | Day 7 |
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Safety Assessment - Neurologic Function | Neurologic function will be assessed using the International Standards for Neurologic Classification of Spinal Cord Injury (ISNCSCI) to determine if the application, 7-day placement, or removal of the NIRS sensor is associated with any deterioration in spinal cord function. | 6 Month |
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Allan Aludino | Contact | 604-875-4111 ext 61689 | allan.aludino@vch.ca |
| Name | Affiliation | Role |
|---|---|---|
| Brian Kwon, MD | University of British Columbia | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Vancouver General Hospital | Recruiting | Vancouver | British Columbia | V5Z1M9 | Canada |
Not provided
| ID | Term |
|---|---|
| D013119 | Spinal Cord Injuries |
| ID | Term |
|---|---|
| D013118 | Spinal Cord Diseases |
| D002493 | Central Nervous System Diseases |
| D009422 | Nervous System Diseases |
| D020196 | Trauma, Nervous System |
Not provided
Not provided
| ID | Term |
|---|---|
| D019265 | Spectroscopy, Near-Infrared |
| ID | Term |
|---|---|
| D003952 | Diagnostic Imaging |
| D019937 | Diagnostic Techniques and Procedures |
| D003933 | Diagnosis |
| D013057 | Spectrum Analysis |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Safety Assessment - Wound Assessment |
The externalization of a foreign body may lead to an increased risk of surgical site infection. Any incidence of wound infection will be monitored and document on a wound assessment form. |
| Day 7 |
| Safety Assessment - Adverse Events | The incidence of AEs in the acute SCI patient population is significant. For the purposes of this study, and in keeping with standard of care on the Acute Spine Unit at study site, all AEs will be recorded utilizing the Spine Adverse Event (SAVES) form, a well-established system for prospectively documenting AEs in spine patients | 6 Months |
| D014947 | Wounds and Injuries |
| D002623 |
| Chemistry Techniques, Analytical |
| D008919 | Investigative Techniques |