Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
This study consisted of a randomized controlled trial group and a long balloon observation group.
In the randomized control group, 280 subjects with in-stent restenosis were planned to be recruited and randomly assigned to the test group and the control group in a 1:1 ratio; 30 consecutive subjects will be enrolled in the long balloon observation group, using graceful molimus release coronary balloon catheter with length of 45mm; All 310 subjects were followed up at baseline, surgery, discharge, 1 month after surgery, 6 months after surgery, 9 months after surgery, 1, 2 and 3 years after surgery, and angiography was performed at 9 months after surgery.
This study consisted of a randomized controlled trial group and a long balloon observation group.
In the randomized control group, 280 subjects with in-stent restenosis were planned to be recruited and randomly assigned to the test group and the control group in a 1:1 ratio; 30 consecutive subjects will be enrolled in the long balloon observation group, using graceful molimus release coronary balloon catheter with length of 45mm; All 310 subjects were followed up at baseline, surgery, discharge, 1 month after surgery, 6 months after surgery, 9 months after surgery, 1, 2 and 3 years after surgery, and angiography was performed at 9 months after surgery.
The primary endpoint was late lumen loss at 9 months.
The study will enroll 310 subjects. The sample size determination process is as follows:
Randomized controlled trial group:
A prospective, multicenter, randomized, controlled, non-inferior clinical trial design was used with the primary endpoint of intrasegonal LLL at 9 months postoperatively. Sample size was calculated according to the following assumptions:
1) According to previous clinical studies, the LLL of the segment 9 months after paclitaxel release coronary catheter (Sequent Please) was 0.46±0.48mm[1] and 0.46±0.51mm[2]. 2) In this study, it was estimated that the mean LLL in the lesion segment of the experimental group and the control group 9 months after surgery was 0.46mm, and the standard deviation was 0.50mm. 3) The clinically acceptable non-infertility threshold was 0.195mm. When the significance level of the statistical test was set as one-sided 2.5% and the assurance level was set as 80%, they were randomly divided into groups at a ratio of 1:1. 4) Considering the abscission rate of 25% (at the same time considering the early withdrawal from the group caused by other reasons and the random setting), 280 patients were finally enrolled, including 140 in the experimental group and 140 in the control group.
Long balloon observation group:
Because the maximum length of Sequent ® Please Neo in the control group was 40mm, subjects suitable for 45mm long balloon could not be randomly enrolled in the randomized controlled trial group. Therefore, this observation group was selected with a sample size of 30 cases.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Biolimus | Experimental | BA9 Drug-eluting Coronary Artery Balloon Catheter Length: 10 / 15 / 20 / 25 / 30 / 35 / 40 /45mm Diameter: 2.0/2.25/2.5/2.75/3.0/3.5/4.0 mm |
|
| SeQuent® Please Neo | Active Comparator | paclitaxel released coronary balloon catheters Length: 10 / 15 / 20 / 25 / 30 / 35 / 40 mm Diameter: 2.0/2.25/2.5/2.75/3.0/3.5/4.0 mm |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Biolimus | Device | 140 patients who met the inclusion/exclusion criteria for in-stent restenosis were enrolled and assigned to the Biolimus treatment group |
|
| Measure | Description | Time Frame |
|---|---|---|
| The late lumen loss | Segmental late lumen loss of target lesions 9 months after surgery | 9 months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Yundai Chen, Ph.D | The First Medical Center of the PLA General Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| The First Medical Center of the PLA General Hospital | Beijing | Beijing Municipality | 100039 | China |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 38742581 | Derived | Chen Y, Gao L, Qin Q, Zhang J, Jia S, Wu M, He Y, Fu G, Liu J, Chen H, Tong Q, Yu Z, An J, Qiu C, Xu B, Cao Y, Wang C, Ma G. Biolimus-coated versus paclitaxel-coated balloons for coronary in-stent restenosis (BIO ASCEND ISR): a randomised, non-inferiority trial. EuroIntervention. 2024 Jul 1;20(13):e806-e817. doi: 10.4244/EIJ-D-24-00295. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003324 | Coronary Artery Disease |
| ID | Term |
|---|---|
| D003327 | Coronary Disease |
| D017202 | Myocardial Ischemia |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| SeQuent® Please Neo | Device | 140 patients who met the inclusion/exclusion criteria for in-stent restenosis were enrolled and assigned to the SeQuent® Please Neo treatment group |
|
| D001161 |
| Arteriosclerosis |
| D001157 | Arterial Occlusive Diseases |
| D014652 | Vascular Diseases |