The aim of this study was to compare and measure the amount of bone density and ridge width gained with motor driven expanders and densifying burs with simultaneous dental implant placement.
Seven patients were treated by the osseodensification technique and another seven were treated by the motor-driven expanders' technique with simultaneous implant placement.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Osseodensification technique | Experimental |
| |
| Motor driven expanders' technique | Active Comparator |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Osseodensification technique | Procedure | Implant bed preparation will be performed according to the manufacturer's guidelines, densifying burs (Densah® Burs) will be used sequentially in densifying mode (counterclockwise drill speed 800-1500 rpm with copious irrigation) to achieve the planned osteotomy diameter and desired ridge expansion. The implant will be then placed in the prepared osteotomy |
| Measure | Description | Time Frame |
|---|---|---|
| Post-operative pain | Pain was assessed using a 10-point Visual Analogue Scale (VAS). The lower values indicates lower pain levels and higher values indicates higher pain levels | up to 1 month |
| Implant stability | Stability was assessed using resonance frequency analysis measured with the Osstell device instrument. The Osstell unit records a numeric value of 1-100 which is referred to as the implant stability quotient (ISQ). The measurements were performed and 3 mean of three readings were recorded. | up to 6 months |
| Bone density | This will be assessed using cone beam computed tomography (CBCT) | up to 6 months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Shaimaa A Abdou, BDS | Faculty of Dentistry, Alexandria University, Egypt | Principal Investigator |
| Magued H Fahmy, PhD | Faculty of Dentistry, Alexandria University, Egypt | Study Director |
| Ahmed O Sweedan, PhD | Faculty of Dentistry, Alexandria University, Egypt | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Faculty of Dentistry, Alexandria University | Alexandria | 21512 | Egypt |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 22117707 | Background | Alghamdi H, Anand PS, Anil S. Undersized implant site preparation to enhance primary implant stability in poor bone density: a prospective clinical study. J Oral Maxillofac Surg. 2011 Dec;69(12):e506-12. doi: 10.1016/j.joms.2011.08.007. | |
| 25615915 | Background | Boustany CM, Reed H, Cunningham G, Richards M, Kanawati A. Effect of a modified stepped osteotomy on the primary stability of dental implants in low-density bone: a cadaver study. Int J Oral Maxillofac Implants. 2015 Jan-Feb;30(1):48-55. doi: 10.11607/jomi.3720. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D016301 | Alveolar Bone Loss |
| ID | Term |
|---|---|
| D001862 | Bone Resorption |
| D001847 | Bone Diseases |
| D009140 | Musculoskeletal Diseases |
| D055093 | Periodontal Atrophy |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Motor driven expanders' technique | Procedure | The technique consisted of preparing the implant bed by progressively increasing the size of the osteotomes until the desired expansion will be achieved. At the planned implant site, a pilot drill 1000 rpm with irrigation until the desired length, then expansion with the series of ridge spreaders and finally using the final drill. The implant will be then placed in the prepared osteotomy. |
|
| 19885432 | Background | Bornstein MM, Cionca N, Mombelli A. Systemic conditions and treatments as risks for implant therapy. Int J Oral Maxillofac Implants. 2009;24 Suppl:12-27. |
| 15142097 | Background | Hatano N, Shimizu Y, Ooya K. A clinical long-term radiographic evaluation of graft height changes after maxillary sinus floor augmentation with a 2:1 autogenous bone/xenograft mixture and simultaneous placement of dental implants. Clin Oral Implants Res. 2004 Jun;15(3):339-45. doi: 10.1111/j.1600-0501.2004.00996.x. |
| 27741329 | Background | Huwais S, Meyer EG. A Novel Osseous Densification Approach in Implant Osteotomy Preparation to Increase Biomechanical Primary Stability, Bone Mineral Density, and Bone-to-Implant Contact. Int J Oral Maxillofac Implants. 2017 Jan/Feb;32(1):27-36. doi: 10.11607/jomi.4817. Epub 2016 Oct 14. |
| 17356368 | Background | Hwang D, Wang HL. Medical contraindications to implant therapy: Part II: Relative contraindications. Implant Dent. 2007 Mar;16(1):13-23. doi: 10.1097/ID.0b013e31803276c8. |
| 24583140 | Background | Jimbo R, Tovar N, Marin C, Teixeira HS, Anchieta RB, Silveira LM, Janal MN, Shibli JA, Coelho PG. The impact of a modified cutting flute implant design on osseointegration. Int J Oral Maxillofac Surg. 2014 Jul;43(7):883-8. doi: 10.1016/j.ijom.2014.01.016. Epub 2014 Feb 28. |
| 19674646 | Background | Johnson C. Measuring Pain. Visual Analog Scale Versus Numeric Pain Scale: What is the Difference? J Chiropr Med. 2005 Winter;4(1):43-4. doi: 10.1016/S0899-3467(07)60112-8. |
| D010510 |
| Periodontal Diseases |
| D009059 | Mouth Diseases |
| D009057 | Stomatognathic Diseases |