This study was designed to evaluate the effect of change of head position on the cuff pressure of TaperGaurd endotracheal tube , compared to cylindrical endotracheal tube during oral surgery.
The patient in cylindrical group (n=26) were intubated with cylindrical shaped endotracheal tube (Unomedical, Kedah, Malaysia) and the patient in tapergaurd group (n=26) was intubated with TaperGuard endotracheal tube (Covidien, Athlone, Ireland). The group allocations were informed to the attending anesthesiologist prior to anesthesia. Tracheal intubation was performed with size of inner diameter 7.0 mm endotracheal tube for male and 6.5 mm endotracheal tube for female by the same anesthesiologist. The anesthesiologist measured cuff pressure and distance from endotracheal tube tip to carina during study period.This study was designed to evaluate the effect of change of head position on the cuff pressure of TaperGaurd endotracheal tube, compared to cylindrical endotracheal tube during oral surgery.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| cylindrical tube group | Active Comparator | The patient in cylindrical tube group (n=26) were intubated with cylindrical shaped endotracheal tube. |
|
| tapergaurd tube group | Experimental | The patient in taperguard tube group (n=26) was intubated with TaperGuard endotracheal tube. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| TaperGuard endotracheal tube | Device | TaperGuard endotracheal tube is intubated |
| |
| Measure | Description | Time Frame |
|---|---|---|
| Cuff pressure | Cuff pressure is measured with a manometer (Mallinckrodt Medical, Hennef, Germany). | 5 minutes after change of head position |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Younghoon Jeon, Mr | kyungook national university hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Kyungpook National University Hospital | Daegu | 700-721 | South Korea |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| cylindrical endotracheal tube |
| Device |
endotracheal tube is intubated |
|