When using nitrous oxide for general anesthesia, nitrous oxide diffusion induces intracuff hyperinflation of the endotracheal tube. Furthermore the difference among various types of cuffed endotracheal tubes in cuff pressure behavior during nitrous oxide exposure.
TaperGuard(TM) tube has been newly introduced and has tapered-shape cuff. In vitro study, the intracuff pressure of TaperGuard(TM) tube was lower than that of conventional tube with cylindrical-shaped cuff of the conventional tube(Hi-Lo(TM) tube). Therefore, this clinical study is needed to evaluate the intracuff pressure during general anesthesia with nitrous oxide exposure.
During 60 minutes after routine anesthetic induction and intubation of the endotracheal tubes, intracuff pressures will be measured every 10 minutes with a manometer (VBM, Sulz, Germany).
60% nitrous oxide will be added at time 0. For 60 minutes from the beginning of general anesthesia, intracuff pressures will be measured every 10 minutes.
After 60 minutes, Intracuff pressures will be maintained around 20 cm H2O during the remaining period of the surgery.
The questionnaire for a sore throat, hoarseness, and dysphagia will be questioned at about 1, 6, and 24 hours after the surgery and the general anesthesia.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Cylindrical-shape cuff ETT (Group C) | Experimental | Control group: Mallinckrodt HiLo(TM) endotracheal tube. Intracuff pressures of the tubes every 10 minutes, Adult patients under general anesthesia with Mallinckrodt Hi-Lo(TM) tube. |
|
| Tapered-shape cuff ETT (Group T) | Experimental | Experimental group: Mallinckrodt TaperGuard(TM) endotracheal tube. Intracuff pressures of the tubes every 10 minutes, Adult patients under general anesthesia with Mallinckrodt TaperGuard(TM) tube. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Cylindrical-shape cuff ETT (Group C) | Device | Randomized allocation of the endotracheal cuffs for general anesthesia, mechanical ventilation will be maintained with Mallinckrodt Hi-Lo(TM) endotracheal tube. |
| Measure | Description | Time Frame |
|---|---|---|
| Intracuff pressure of the endotracheal tube after 60 min (1 hour) with exposure to nitrous oxide | One hour after the exposure to nitrous oxide under general anesthesia |
| Measure | Description | Time Frame |
|---|---|---|
| Intracuff pressure of the endotracheal tubes | Intracuff pressures will be measured with a manometer (VBM, Sulz, Germany) | 0, 10, 20, 30, 40, 50 minutes after exposure to nitrous oxide |
| Postoperative sore throat: incidence |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Junyong In, M.D., Ph.D. | DongGuk University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Dongguk University Ilsan Hospital | Goyang | Gyeonggido | 10326 | South Korea |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 23400983 | Background | Tsuboi S, Miyashita T, Yamaguchi Y, Yamamoto Y, Sakamaki K, Goto T. The TaperGuard endotracheal tube intracuff pressure increase is less than that of the Hi-Lo tube during nitrous oxide exposure: a model trachea study. Anesth Analg. 2013 Mar;116(3):609-12. doi: 10.1213/ANE.0b013e318279b399. Epub 2013 Feb 11. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Tapered-shape cuff ETT (Group T) | Device | Randomized allocation of the endotracheal cuffs for general anesthesia, mechanical ventilation will be maintained with Mallinckrodt TaperGuard(TM) endotracheal tube. |
|
|
| About 1, 6, 24 hours after termination of anesthesia |
| Postoperative hoarseness: incidence | About 1, 6, 24 hours after termination of anesthesia |
| Postoperative dysphagia: incidence | About 1, 6, 24 hours after termination of anesthesia |
| ID | Term |
|---|---|
| D014133 | Tracheal Diseases |
| ID | Term |
|---|---|
| D012140 | Respiratory Tract Diseases |
Not provided