Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The objective of this study is to evaluate the safety and efficacy of 1064-nm Picosecond laser 1064 With Microlens Array for Pore tightening.
The Safety and Efficacy of Picosecond laser 1064 Nanometers With Microlens Array for Pore tightening; a Pilot Study Primary outcome : pore size Secondary outcome : side effect, patient satisfaction, global evaluation the patient recieved laser treament once a month for 3 months and then follow up after last treatment at 1, 3 ,6 month
Enlarged facial pores is one of the skin signs in photoaging. There are 3 major clinical causes of enlarged facial pores: highs sebum excretion, decreased elasticity around pores and increased hair follicle volume. Possible causative factors of enlarged facial pores include many exogenous and endogenous factors include genetic predisposition, seborrhea and chronic ultraviolet light exposure. Picosecond laser are new device which has been used in skin rejuvenation. The main mechanism of action is laser induced optical breakdown (LIOB).
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Fractional picosecond laser 1,064 nm laser | Experimental | 1 arm The subjects with enlarged pores were treated with fractional picosecond laser 1,064 nm laser |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Fractional picosecond 1064 nm laser | Device | The parameter of laser was 8 mm spot size, 0.8 mJ/CM2, 750 ps, 5 Hz, 2 passes The treatment was done in every 4 weeks for 3 sessions. |
| Measure | Description | Time Frame |
|---|---|---|
| Change in pore size by Antera 3D image | change from baseline in pore size at 6 months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| woraphong Manuskiatti, M.D. | Contact | 02-419-1000 | doctorlaser@gmail.com | |
| Siriwan palawisuth, M.D. | Contact | 02-419-1000 | siriwan_monk@yahoo.com |
| Name | Affiliation | Role |
|---|---|---|
| woraphong Manuskiatti, M.D. | Mahidol University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Department of Dermatology, Siriraj Hospital, Mahidol University | Recruiting | Bangkok | 10700 | Thailand |
Not provided
| ID | Term |
|---|---|
| D007834 | Lasers |
| ID | Term |
|---|---|
| D055096 | Optical Devices |
| D004864 | Equipment and Supplies |
| D055618 | Radiation Equipment and Supplies |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided