Not provided
Not provided
Not provided
Not provided
Not provided
required license
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
To compare the clinical performance of high-viscosity glass ionomer, flowable composite, bulkfill composite and nanohybrid composite restorations in non-carious cervical lesions (NCCLs).
One hundred fourty NCCLs were randomised into four groups according to a split-mouth design. Clinical evaluations will be performed after 1 week, 3 months, 6 months, using FDI (World Dental Federation) criteria.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| High-viscosity glass ionomer | Experimental |
| |
| flowable composite | Experimental |
| |
| bulkfill composite | Experimental |
| |
| nanohybrid composite | Experimental |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| EQUIA Forte Fil | Other | Apply cavity conditioner (20% polyacrylic acid) 10 s on enamel and dentine, rinse Mix 10 s and apply bulk-fill Apply EQUIA coat and light cure for 20 s unit |
| Measure | Description | Time Frame |
|---|---|---|
| evaluation of restoration on cervical lesions | According to FDI criteria (aesthetic, biological and fuctional) score 1, clinically very good; score 2, clinically good; score 3, clinically sufficient; score 4, clinically unsatisfactory; score 5, clinically poor. Scores 1-3 show clinically acceptable restoration, while scores 4 and 5 indicate failure | 6 months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Gül Yıldız Telatar, Dr | Recep Tayyip Erdogan University Dentistry Faculty | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Recep Tayyip Erdogan University Dentistry Faculty | Rize | 53000 | Turkey (Türkiye) |
Data will be available within 1 years of study completion
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Clearfil Majesty Esthetic | Other | Apply in 2-mm increment, light cure for 20 s |
|
| NexComp Flow | Other | Apply in 2-mm increment light cure for 20 s |
|
| 3M Espe Bulk-fill | Other | Apply in single increment up to 4 mm; light curing for 20 s |
|