Implication and evaluation of a non-invasive sensory feedback system in hand prostheses in everyday life.
A non invasive sensory feedback system in embedded in the prosthetic socket will be tested on forearm amputees in their everday life. Pretests and follow up will contain objective outcome assessments and semi-structured interviews.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| sensory feedback | Experimental | A non-invasive air-mediated sensory feedback system embedded in the prosthesis socket. Group description: Individuals with acquired forearm amputation. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| smartskin non-invasive sensory feedback | Device | The sensory feedback system used was a simple non-invasive, non-electronic system based on air-mediated pressure. A silicone glove with bulbs (35 mm in length) volar in every fingertip was made and applied on a VariPlus Speed hand (OttoBock), size 7¾. The sensory feedback system was embedded in the prosthetic socket. |
| Measure | Description | Time Frame |
|---|---|---|
| Assessment of Myoelectric Control - ACMC | An observational assessment where you rate the subjects' capacity of myoelectric control in a bimanual activity. The scoring was made by an experienced external rater. | 2 days |
| Task performance questionnaire | 21 questions about sensory feedback from the prosthesis, agency, body ownership, performance in activity and phantom limb pain. Self-administered estimation on a 7 grade Likert-scale. | 2 days |
| Pointing task | A objective measurement of body ownership. The subject are asked to mark on a ruler, with the hand prosthesis hidden, where they estimate the location of the prosthetic index finger. | 2 days |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 32733187 | Derived | Wijk U, Carlsson IK, Antfolk C, Bjorkman A, Rosen B. Sensory Feedback in Hand Prostheses: A Prospective Study of Everyday Use. Front Neurosci. 2020 Jul 7;14:663. doi: 10.3389/fnins.2020.00663. eCollection 2020. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D000673 | Amputation, Traumatic |
| ID | Term |
|---|---|
| D014947 | Wounds and Injuries |
Not provided