The purpose of this research is the evaluation of a combined coaxial optical coherence tomography (OCT) system to image retina/choroid and to evaluate if post processing of the data can give us insights into property of the tissue imaged.
Histology studies have shown that many disorders of the retina and choroid such as age-related macular degeneration is associated with a build up abnormal deposits, in the retina or subretinal space. Being able to detect subtle changes in retina and choroidal structure is crucial for better understanding and monitoring of this potentially blinding condition. This study aims to commercially available Spectralis® OCT-system with a central wavelength of 880nm explore the ability of a confocal scanning laser ophthalmoscope (cSLO) for OCT imaging utilising a modified by the addition of a longer wavelength OCT (1075nm , a wavelength deployed on other commercially available OCT scanners). Other commercially available OCT scanners used longer wavelengths to allow deeper penetration and enhanced visualisation of subretinal tissue but less inner retinal detail. Combing both wavelengths could have the advantage of allowing optimum viualisation of inner and subretinal structures. The ability of the systems to acquire repeatable and good quality images of retinal and choroidal structural detail at matching location and compare the results from the two instruments will be evaluated. In addition processing of the images reflectivity with two different wavelength should give us insight into the nature of any abnormal material.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Diseased Retina |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Combined Coaxial Optical Coherence Tomography | Device | Taking images of the retina with two wavelengths |
|
| Measure | Description | Time Frame |
|---|---|---|
| Test retest reliability | Comparison of device test retest variability with those of standard OCT for measurement of tissue reflectivity. | 14 months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
People with diseased retina
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Moorfields Eye Hospital NHS Foundation Trust, 162 City Road | London | EC1V 2PD | United Kingdom |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003930 | Diabetic Retinopathy |
| D012162 | Retinal Degeneration |
| D058499 | Retinal Dystrophies |
| ID | Term |
|---|---|
| D012164 | Retinal Diseases |
| D005128 | Eye Diseases |
| D003925 | Diabetic Angiopathies |
| D014652 | Vascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
| D002318 |
| Cardiovascular Diseases |
| D048909 | Diabetes Complications |
| D003920 | Diabetes Mellitus |
| D004700 | Endocrine System Diseases |
| D015785 | Eye Diseases, Hereditary |