This study is to test the system composed by a 3D virtual environment, attached to the Leap Motion, evaluating its effects on the rehabilitation of hand movements in patients with motor alteration.
In order to elaborate the virtual environment, softwares for 3D content creation were used. The virtual environment is formed by four phases, each one having three spheres that are supposed to be inserted, one by one, into a hole located on the scenario floor. Each phase presents a level of difficulty, from pushing the object to performing the grip movement. By the end of each phase, a log file is generated with the time spent on it.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Experimental group | Experimental | For the tests, the volunteers used the access device (Leap Motion) and a computer that were previously installed. The intervention was composed by 8 sessions of 15 minutes each, where the volunteers used a virtual environment attached it to a Leap Motion, which is a sensor that allows to capture the movements that are produced by the hands and reproduce them in a computer through a 3D virtual environment in order to stimulate the execution of their finer movements. The strength (Jamar) and motor coordination (wooden box) evaluations were made in the first, fourth and eighth sessions with the objective of checking the gain progression or not of motion coordination and grip strength. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Jamar | Diagnostic Test | The grip strength was evaluated through a dynamometer JAMAR 5030-J, formed by two parallel steel bars, one stationary and a mobile one, which can be adjusted in five different positions. The volunteer was sitting with a neutrally rotated abducted shoulder, elbow flexed at 90°, the forearm in neutral position, and the wrist between 0° and 30° of extension, 0° to 15° of ulnar variance and it was requested that he or she made the grip movement. This test was performed three times with a one-minute-break between each one. |
| Measure | Description | Time Frame |
|---|---|---|
| Virtual environment | The intervention was composed by 8 sessions of 15 minutes each, where the volunteers used a virtual environment attached it to a Leap Motion, which is a sensor that allows to capture the movements that are produced by the hands and reproduce them in a computer through a 3D virtual environment in order to stimulate the execution of their finer movements. | 120 minutes |
| Measure | Description | Time Frame |
|---|---|---|
| Wooden box | The motor coordination evaluation was made in the first, fourth and eighth sessions. Each volunteer used three balls, or spheres, of different sizes (small, medium, large). The objective was to insert each ball in each orifice. The time was measured with a chronometer. | Immediately after at the Session 1, 4 and 8. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Terigi A Scardovelli, Ph.D | University of Mogi das Cruzes | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Terigi Augusto Scardovelli | Mogi das Cruzes | São Paulo | 08780-911 | Brazil |
Not provided
| ID | Term |
|---|---|
| D006230 | Hand Injuries |
| D004194 | Disease |
| ID | Term |
|---|---|
| D014947 | Wounds and Injuries |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Wooden box | Diagnostic Test | The motor coordination evaluation was made through the measurement of the time spent to perform the task of fitting. To do so, a wooden box was built. In its upper part, there is a circular orifice with 6 cm of diameter. |
|
| Virtual environment | Other | The system proposed is composed by a virtual environment and an access device. The Leap Motion was used as the access device, making it possible to capture the movements performed by the hands. |
|
| Dynamometer JAMAR |
The grip strength (kgf) was evaluated in the first, fourth and eighth sessions. |
| Immediately after at the Session 1, 4 and 8. |