Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| University of Hull | OTHER |
Not provided
Not provided
Not provided
Not provided
Not provided
High intensity interval training (HIIT) and circuit training (CT) are popular methods of exercise, eliciting improvements in cardiorespiratory fitness (CRF). However direct comparisons of these two training methods are limited.
Study Design Participants were enrolled in a randomised control trial at the University of Hull to either eight weeks of High intensity interval training (HIIT) or Circuit Training (CT) (two supervised sessions per week, accompanied by an exercise physiologist). A sample size of 38 using G Power 3.1 software was calculated based on previously published data in which the mean difference between HIIT and Moderate Intensity Continuous Training (MICT) was 3.2 ml.kg-1.min-1 with a pooled standard deviation of 3 ml.kg-1.min-1. Statistical significance was set at 0.05 and power set to 0.95. To allow for 10% attrition 42 individuals were recruited to the study. To assess the effectiveness of the interventions as determined by maximal oxygen consumption (VO2max), a maximal cardiopulmonary exercise test (CPET) to volitional exhaustion on an electronically braked cycle ergometer at baseline (visit one), and following an eight-week exercise intervention of HIIT or CT (visit two) was conducted. When attending the assessments participants were asked not to take part in any strenuous exercise 24 hours prior to the appointment, to wear suitable comfortable clothing and avoid a large meal. Visit two CPET was performed within six days of completing the exercise interventions. A thorough warm-up and cool down before and after each exercise session. All were asked to maintain their habitual physical activity patterns during the intervention. Body mass index (BMI) was calculated by dividing body weight by height in meters squared and was presented as kg.m-2. Resting blood pressure was measured after 15 minutes of rest using a sphygmomanometer (A.C. Cossor & Son Ltd, London UK) and stethoscope (3M Healthcare, St Paul, MN). To provide a comprehensive account of the study the Consensus on Exercise Reporting Template (CERT) was consulted.
Participants Ethical approval was provided by the School of Life Sciences ethics committee at the University of Hull which was in accordance with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. A total of 42 apparently healthy men and women between the age of 18-65 years were recruited to the study. Enrolled individuals reported no medical history of cardiometabolic or limiting respiratory disease, were non-smokers, had a body mass index <30 kg.m-2, classified as recreationally active and none were taking any medication that would affect heart rate. As a condition of enrolment, those over 45 years obtained written medical clearance from a general practitioner and underwent resting and exercise 12-lead electrocardiogram (ECG) (GE Healthcare, Chalfont St Giles, United Kingdom). Written informed consent and a pre-exercise medical questionnaire was completed by all.
Cardiopulmonary Exercise Testing Maximal CPETs were conducted in accordance with the American Thoracic Society (ATS) and the American College of Chest Physicians (ACCP) guidelines. An Oxycon pro (Jaeger, Hoechburg, Germany) breath by breath metabolic cart was used to collect respiratory gas exchange data. Automatic and manual calibration evaluated ambient temperature, humidity, barometric pressure and altitude. Calibration of the air flow volume was conducted using a 3 litre syringe and by automatic calibration. Two-point gas calibration was also conducted to ensure accurate measures of inspired oxygen and expired carbon dioxide. Tests were performed on a GE e-bike ergometer (GE Healthcare, Buckinghamshire, UK) using a ramp protocol. The protocol consisted of a three-minute rest phase, three minutes of unloaded cycling, followed by a personalised ramp test (ramp rate ranged between 15 and 30 watts) with work rate continually increased every one to three seconds. Participants performed the same ramp rate pre and post testing. Participants were asked to pedal at a cadence of 70 rpm until they reached volitional exhaustion at a protocol duration between eight to twelve minutes. Self-reported rating of perceived exertion (RPE) scores using the 6-20 scale and heart rate (HR) (FT1 heart rate monitor, Polar Electro, Finland) was recorded during the last five seconds of each minute of the test, at maximum exercise and during the recovery period. Together with verbal encouragement to volitional exhaustion, VO2max was attained by participants achieving at least two of the following criteria, VO2 plateau as determined by a failure of VO2 increase by 150 ml/min with further increases in workload analysed by breath by breath gas exchange data averaged over 15 seconds, respiratory exchange ratio (RER) > 1.10, achieve > 85% age predicated heart rate maximum (HRmax) and a RPE > 17 on the 6-20 Borg scale. VO2 at the ventilatory anaerobic threshold (VAT) was defined using the V slope method and verified using ventilatory equivalents. Peak power output (PPO) (watts) and HRmax were defined as the highest value achieved during the CPET with maximum oxygen and heart rate (VO2 /HR) determined by the ratio of VO2max and HRmax.
Training Interventions The HIIT group were asked to perform ten one-minute HIIT intervals, each followed by one minute of active recovery (AR) (total exercise time 20 minutes). Resulting from the CPET, HIIT was set at above 85% HRmax with a specific HR designated for this criterion. Active recovery was set at a load corresponding to 25-50 watts. Sessions were performed on a Wattbike trainer (Wattbike Ltd, Nottingham, UK). The CT group completed a practical seven-station mixed modality exercise circuit (cycle ergometer, rower, treadmill, sit to stand/squats, knee to elbow and leg kickback with bicep curl) at an intensity of 60-80% HRmax (calculated from CPET). No resistance equipment was involved, only body weight. Participants initially performed 20 minutes of CT with duration increased by five minutes per week until the desired 40 minutes. Each station was occupied for three to six minutes depending on session duration, moving from one station to the next with minimal rest. During both interventions, HR was measured in last 5 seconds of each station/interval using a FT1 polar heart rate monitor (Polar Electro, Finland) with each CT session timed using a stop watch (Axprod S.L, Guipuzcoa, Spain). Intensity for both interventions was adjusted throughout by the investigator to ensure an appropriate HR range and successful completion of the protocol. Participants were made aware of their HR ranges and verbal encouragement was given by the physiologist to help achieve and maintain these thresholds. Energy expenditure between HIIT and CT was not matched.
To assess the validity of the exercise interventions, participant fidelity to the desired exercise intensity was determined using cut points of >85% HRmax and 60-80% HRmax for HIIT and CT respectively and reported using previous examples. These values were calculated using the participants mean heart rate for each individual interval or station over the 16 sessions and was expressed as a percentage of HRmax as determined by CPET at visit 1. Specific fidelity thresholds were consulted to determine low (<50%), moderate (50-70%) and high (>70%) compliance. Adherence was determined as a percentage of completed sessions, with 14 (> 85%) being the threshold for completion.
Statistical Analysis Statistical analysis was conducted using Statistical Package for the Social Sciences (SPSS) version 24 (IBM, New York, USA). An independent t-test was used to identify group differences at baseline. Assumptions of normality were verified using the Shapiro-Wilk test. Skewness and kurtosis of distribution was visually examined. Non-normally distributed data was presented as median and interquartile range (IQR). A two-way (condition x time) repeated measures analysis of variance (ANOVA) was used to compare CRF pre-and post-training. Post-hoc analysis for the main effects and interactions was assessed using a Bonferroni adjustment. Group differences were compared using independent t tests. Variables were displayed as mean with 95% confidence intervals (95% CI) or standard deviation where specified. Partial eta squared effect sizes were also calculated with 0.01, 0.06 and 0.14 representing small, medium and large effect sizes, respectively.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| High intensity interval training | Experimental | HIIT was set at > 85% HRmax. Active recovery was set at 25-50 watts. Sessions were performed using cycle ergometry. |
|
| Circuit training | Active Comparator | The CT group completed a practical seven-station mixed modality exercise circuit (cycle ergometer, rower, treadmill, sit to stand, knee to elbow and leg kickback with bicep curl) at an intensity of 60-80%. Participants initially performed 20 minutes of CT with duration gradually increased to the desired 40 minutes as tolerated. Each station was occupied for three to six minutes depending on session duration with minimal rest in-between. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| High intensity interval training | Other | Participants performed HIIT twice a week for eight weeks. Findings were compared to moderate intensity continuous training which followed the same exercise frequency and duration |
| Measure | Description | Time Frame |
|---|---|---|
| Maximal Oxygen Consumption (ml.Kg-1.Min-1) | Maximal oxygen consumption (ml.kg-1.min-1), as determined during a cardiopulmonary exercise test (CPET) represents the upper limit of aerobic fitness in humans. A low VO2max is associated with a greater risk of premature all-cause and cardiovascular mortality, independent of traditional risk factors and physical activity status. Conversely, increasing VO2max through exercise training may improve cardiometabolic health, quality of life and increase life-expectancy | Baseline and 8 weeks |
| Measure | Description | Time Frame |
|---|---|---|
| Oxygen Consumption at the Ventilatory Anaerobic Threshold | Oxygen consumption at the Ventilatory Anaerobic Threshold ml/kg/min. This measure will assess if individuals can exercise at higher intensities before lactate accumulation, thus becoming 'physiologically efficient | Baseline and 8 weeks |
| Measure | Description | Time Frame |
|---|---|---|
| Intervention Fidelity - Participants That Complied With the Exercise Protocols | To assess if the interventions were delivered as intended, percentage of participants that complied with the exercise protocols | 8 weeks |
| The Percentage of Individuals That Responsed to the Intervention |
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Stefan Birkett, PhD | University of Central Lancashire | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Univeristy of Hull | Hull | Kingston Upon Hull | HU67RX | United Kingdom |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 27881567 | Background | Ross R, Blair SN, Arena R, Church TS, Despres JP, Franklin BA, Haskell WL, Kaminsky LA, Levine BD, Lavie CJ, Myers J, Niebauer J, Sallis R, Sawada SS, Sui X, Wisloff U; American Heart Association Physical Activity Committee of the Council on Lifestyle and Cardiometabolic Health; Council on Clinical Cardiology; Council on Epidemiology and Prevention; Council on Cardiovascular and Stroke Nursing; Council on Functional Genomics and Translational Biology; Stroke Council. Importance of Assessing Cardiorespiratory Fitness in Clinical Practice: A Case for Fitness as a Clinical Vital Sign: A Scientific Statement From the American Heart Association. Circulation. 2016 Dec 13;134(24):e653-e699. doi: 10.1161/CIR.0000000000000461. Epub 2016 Nov 21. | |
| 23295916 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | High Intensity Interval Training | High intensity interval training (HIIT) was set at > 85% HRmax. Active recovery was set at 25-50 watts. Sessions were performed using cycle ergometry. High intensity interval training: Participants performed HIIT twice a week for eight weeks. Findings were compared to moderate intensity continuous training which followed the same exercise frequency and duration |
| FG001 | Circuit Training | The Circuit Training (CT) group completed a practical seven-station mixed modality exercise circuit (cycle ergometer, rower, treadmill, sit to stand, knee to elbow and leg kickback with bicep curl) at an intensity of 60-80%. Participants initially performed 20 minutes of CT with duration gradually increased to the desired 40 minutes as tolerated. Each station was occupied for three to six minutes depending on session duration with minimal rest in-between. Circuit training: The CT group completed a practical seven-station mixed modality exercise circuit (cycle ergometer, rower, treadmill, sit to stand, knee to elbow and leg kickback with bicep curl) at an intensity of 60-80% HRmax twice per week for eight weeks. Participants initially performed 20 minutes of CT with duration gradually increased to the desired 40 minutes as tolerated |
| Title | Milestones | Reasons Not Completed | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
|
no race or ethnicity exclusion
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | High Intensity Interval Training | Perform High intensity interval training twice per week for 8 weeks |
| BG001 | Circuit Training | Perform Circuit training twice per week for 8 weeks |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Categorical | Count of Participants |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Maximal Oxygen Consumption (ml.Kg-1.Min-1) | Maximal oxygen consumption (ml.kg-1.min-1), as determined during a cardiopulmonary exercise test (CPET) represents the upper limit of aerobic fitness in humans. A low VO2max is associated with a greater risk of premature all-cause and cardiovascular mortality, independent of traditional risk factors and physical activity status. Conversely, increasing VO2max through exercise training may improve cardiometabolic health, quality of life and increase life-expectancy | Posted | Mean | Standard Deviation | ml/kg/min | Baseline and 8 weeks |
|
Data was collected for each participant over the course of their intervention which was 8 weeks
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | High Intensity Interval Training | HIIT was set at > 85% HRmax. Active recovery was set at 25-50 watts. Sessions were performed using cycle ergometry. High intensity interval training: Participants performed HIIT twice a week for eight weeks. Findings were compared to moderate intensity continuous training which followed the same exercise frequency and duration |
Not provided
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Stefan Birkett Lecturer in Exercise Science | University of Central Lancashire | 01772 893325 | sbirkett4@uclan.ac.uk |
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| ICF | No | No | Yes | Informed Consent Form | May 11, 2017 | Dec 16, 2019 | ICF_000.pdf |
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | May 11, 2017 | Dec 16, 2019 | Prot_SAP_001.pdf |
Not provided
| ID | Term |
|---|---|
| D000072696 | High-Intensity Interval Training |
| D065327 | Circuit-Based Exercise |
| ID | Term |
|---|---|
| D064797 | Physical Conditioning, Human |
| D015444 | Exercise |
| D009043 | Motor Activity |
| D009068 | Movement |
Not provided
Not provided
Participants were randomised to either high or moderate intensity exercise
Not provided
Not provided
Not provided
Not provided
| Circuit training | Other | The CT group completed a practical seven-station mixed modality exercise circuit (cycle ergometer, rower, treadmill, sit to stand, knee to elbow and leg kickback with bicep curl) at an intensity of 60-80% HRmax twice per week for eight weeks. Participants initially performed 20 minutes of CT with duration gradually increased to the desired 40 minutes as tolerated |
|
If participants had a postive increased in maximal oxygen consumption following the two interventions |
| 8 weeks |
| Background |
| Kaminsky LA, Arena R, Beckie TM, Brubaker PH, Church TS, Forman DE, Franklin BA, Gulati M, Lavie CJ, Myers J, Patel MJ, Pina IL, Weintraub WS, Williams MA; American Heart Association Advocacy Coordinating Committee, Council on Clinical Cardiology, and Council on Nutrition, Physical Activity and Metabolism. The importance of cardiorespiratory fitness in the United States: the need for a national registry: a policy statement from the American Heart Association. Circulation. 2013 Feb 5;127(5):652-62. doi: 10.1161/CIR.0b013e31827ee100. Epub 2013 Jan 7. No abstract available. |
| 20923918 | Background | Lee DC, Artero EG, Sui X, Blair SN. Mortality trends in the general population: the importance of cardiorespiratory fitness. J Psychopharmacol. 2010 Nov;24(4 Suppl):27-35. doi: 10.1177/1359786810382057. |
| 24144531 | Background | Weston KS, Wisloff U, Coombes JS. High-intensity interval training in patients with lifestyle-induced cardiometabolic disease: a systematic review and meta-analysis. Br J Sports Med. 2014 Aug;48(16):1227-34. doi: 10.1136/bjsports-2013-092576. Epub 2013 Oct 21. |
| 24743927 | Background | Weston M, Taylor KL, Batterham AM, Hopkins WG. Effects of low-volume high-intensity interval training (HIT) on fitness in adults: a meta-analysis of controlled and non-controlled trials. Sports Med. 2014 Jul;44(7):1005-17. doi: 10.1007/s40279-014-0180-z. |
| 25902066 | Background | Taylor KL, Weston M, Batterham AM. Evaluating intervention fidelity: an example from a high-intensity interval training study. PLoS One. 2015 Apr 22;10(4):e0125166. doi: 10.1371/journal.pone.0125166. eCollection 2015. |
| 22289907 | Background | Gibala MJ, Little JP, Macdonald MJ, Hawley JA. Physiological adaptations to low-volume, high-intensity interval training in health and disease. J Physiol. 2012 Mar 1;590(5):1077-84. doi: 10.1113/jphysiol.2011.224725. Epub 2012 Jan 30. |
| 27852718 | Background | McGregor G, Nichols S, Hamborg T, Bryning L, Tudor-Edwards R, Markland D, Mercer J, Birkett S, Ennis S, Powell R, Begg B, Haykowsky MJ, Banerjee P, Ingle L, Shave R, Backx K. High-intensity interval training versus moderate-intensity steady-state training in UK cardiac rehabilitation programmes (HIIT or MISS UK): study protocol for a multicentre randomised controlled trial and economic evaluation. BMJ Open. 2016 Nov 16;6(11):e012843. doi: 10.1136/bmjopen-2016-012843. |
| 24281825 | Background | Esfandiari S, Sasson Z, Goodman JM. Short-term high-intensity interval and continuous moderate-intensity training improve maximal aerobic power and diastolic filling during exercise. Eur J Appl Physiol. 2014 Feb;114(2):331-43. doi: 10.1007/s00421-013-2773-x. Epub 2013 Nov 27. |
| 27255523 | Background | Sawyer BJ, Tucker WJ, Bhammar DM, Ryder JR, Sweazea KL, Gaesser GA. Effects of high-intensity interval training and moderate-intensity continuous training on endothelial function and cardiometabolic risk markers in obese adults. J Appl Physiol (1985). 2016 Jul 1;121(1):279-88. doi: 10.1152/japplphysiol.00024.2016. Epub 2016 Jun 2. |
| 26440134 | Background | Baekkerud FH, Solberg F, Leinan IM, Wisloff U, Karlsen T, Rognmo O. Comparison of Three Popular Exercise Modalities on V O2max in Overweight and Obese. Med Sci Sports Exerc. 2016 Mar;48(3):491-8. doi: 10.1249/MSS.0000000000000777. |
| 23861854 | Background | Boyd JC, Simpson CA, Jung ME, Gurd BJ. Reducing the intensity and volume of interval training diminishes cardiovascular adaptation but not mitochondrial biogenesis in overweight/obese men. PLoS One. 2013 Jul 5;8(7):e68091. doi: 10.1371/journal.pone.0068091. Print 2013. |
| 29396978 | Background | Stavrinou PS, Bogdanis GC, Giannaki CD, Terzis G, Hadjicharalambous M. High-intensity Interval Training Frequency: Cardiometabolic Effects and Quality of Life. Int J Sports Med. 2018 Feb;39(3):210-217. doi: 10.1055/s-0043-125074. Epub 2018 Feb 2. |
| 21448086 | Background | Hood MS, Little JP, Tarnopolsky MA, Myslik F, Gibala MJ. Low-volume interval training improves muscle oxidative capacity in sedentary adults. Med Sci Sports Exerc. 2011 Oct;43(10):1849-56. doi: 10.1249/MSS.0b013e3182199834. |
| 21868679 | Background | Little JP, Gillen JB, Percival ME, Safdar A, Tarnopolsky MA, Punthakee Z, Jung ME, Gibala MJ. Low-volume high-intensity interval training reduces hyperglycemia and increases muscle mitochondrial capacity in patients with type 2 diabetes. J Appl Physiol (1985). 2011 Dec;111(6):1554-60. doi: 10.1152/japplphysiol.00921.2011. Epub 2011 Aug 25. |
| 27707738 | Background | Slade SC, Dionne CE, Underwood M, Buchbinder R. Consensus on Exercise Reporting Template (CERT): Explanation and Elaboration Statement. Br J Sports Med. 2016 Dec;50(23):1428-1437. doi: 10.1136/bjsports-2016-096651. Epub 2016 Oct 5. |
| 12738602 | Background | Ross RM. ATS/ACCP statement on cardiopulmonary exercise testing. Am J Respir Crit Care Med. 2003 May 15;167(10):1451; author reply 1451. doi: 10.1164/ajrccm.167.10.950. No abstract available. |
| 7154893 | Background | Borg GA. Psychophysical bases of perceived exertion. Med Sci Sports Exerc. 1982;14(5):377-81. |
| 3087938 | Background | Beaver WL, Wasserman K, Whipp BJ. A new method for detecting anaerobic threshold by gas exchange. J Appl Physiol (1985). 1986 Jun;60(6):2020-7. doi: 10.1152/jappl.1986.60.6.2020. |
| 20965889 | Background | Nordestgaard BG, Chapman MJ, Ray K, Boren J, Andreotti F, Watts GF, Ginsberg H, Amarenco P, Catapano A, Descamps OS, Fisher E, Kovanen PT, Kuivenhoven JA, Lesnik P, Masana L, Reiner Z, Taskinen MR, Tokgozoglu L, Tybjaerg-Hansen A; European Atherosclerosis Society Consensus Panel. Lipoprotein(a) as a cardiovascular risk factor: current status. Eur Heart J. 2010 Dec;31(23):2844-53. doi: 10.1093/eurheartj/ehq386. Epub 2010 Oct 21. |
| Background | Richardson JTE. Eta squared and partial eta squared as measures of effect size in educational research. Educational Research Review. 2011;6(2):135-47. doi:https://doi.org/10.1016/j.edurev.2010.12.001. |
| 24917354 | Background | Matsuo T, Saotome K, Seino S, Eto M, Shimojo N, Matsushita A, Iemitsu M, Ohshima H, Tanaka K, Mukai C. Low-volume, high-intensity, aerobic interval exercise for sedentary adults: VO(2)max, cardiac mass, and heart rate recovery. Eur J Appl Physiol. 2014 Sep;114(9):1963-72. doi: 10.1007/s00421-014-2917-7. Epub 2014 Jun 11. |
| 27798054 | Background | Ingle L, Mellis M, Brodie D, Sandercock GR. Associations between cardiorespiratory fitness and the metabolic syndrome in British men. Heart. 2017 Apr;103(7):524-528. doi: 10.1136/heartjnl-2016-310142. Epub 2016 Oct 25. |
| 19454641 | Background | Kodama S, Saito K, Tanaka S, Maki M, Yachi Y, Asumi M, Sugawara A, Totsuka K, Shimano H, Ohashi Y, Yamada N, Sone H. Cardiorespiratory fitness as a quantitative predictor of all-cause mortality and cardiovascular events in healthy men and women: a meta-analysis. JAMA. 2009 May 20;301(19):2024-35. doi: 10.1001/jama.2009.681. |
| 23470301 | Background | Currie KD, Dubberley JB, McKelvie RS, MacDonald MJ. Low-volume, high-intensity interval training in patients with CAD. Med Sci Sports Exerc. 2013 Aug;45(8):1436-42. doi: 10.1249/MSS.0b013e31828bbbd4. |
| 19443744 | Background | McKay BR, Paterson DH, Kowalchuk JM. Effect of short-term high-intensity interval training vs. continuous training on O2 uptake kinetics, muscle deoxygenation, and exercise performance. J Appl Physiol (1985). 2009 Jul;107(1):128-38. doi: 10.1152/japplphysiol.90828.2008. Epub 2009 May 14. |
| 28133739 | Background | Montero D, Lundby C. Refuting the myth of non-response to exercise training: 'non-responders' do respond to higher dose of training. J Physiol. 2017 Jun 1;595(11):3377-3387. doi: 10.1113/JP273480. Epub 2017 May 14. |
| 8186762 | Background | Bhambhani Y, Norris S, Bell G. Prediction of stroke volume from oxygen pulse measurements in untrained and trained men. Can J Appl Physiol. 1994 Mar;19(1):49-59. doi: 10.1139/h94-003. |
| 17661072 | Background | Daussin FN, Ponsot E, Dufour SP, Lonsdorfer-Wolf E, Doutreleau S, Geny B, Piquard F, Richard R. Improvement of VO2max by cardiac output and oxygen extraction adaptation during intermittent versus continuous endurance training. Eur J Appl Physiol. 2007 Oct;101(3):377-83. doi: 10.1007/s00421-007-0499-3. Epub 2007 Jul 28. |
| 20100740 | Background | Little JP, Safdar A, Wilkin GP, Tarnopolsky MA, Gibala MJ. A practical model of low-volume high-intensity interval training induces mitochondrial biogenesis in human skeletal muscle: potential mechanisms. J Physiol. 2010 Mar 15;588(Pt 6):1011-22. doi: 10.1113/jphysiol.2009.181743. Epub 2010 Jan 25. |
| 27669447 | Background | Astorino TA, Edmunds RM, Clark A, King L, Gallant RA, Namm S, Fischer A, Wood KM. High-Intensity Interval Training Increases Cardiac Output and V O2max. Med Sci Sports Exerc. 2017 Feb;49(2):265-273. doi: 10.1249/MSS.0000000000001099. |
| 17414804 | Background | Helgerud J, Hoydal K, Wang E, Karlsen T, Berg P, Bjerkaas M, Simonsen T, Helgesen C, Hjorth N, Bach R, Hoff J. Aerobic high-intensity intervals improve VO2max more than moderate training. Med Sci Sports Exerc. 2007 Apr;39(4):665-71. doi: 10.1249/mss.0b013e3180304570. |
| 20661160 | Background | Ziemann E, Grzywacz T, Luszczyk M, Laskowski R, Olek RA, Gibson AL. Aerobic and anaerobic changes with high-intensity interval training in active college-aged men. J Strength Cond Res. 2011 Apr;25(4):1104-12. doi: 10.1519/JSC.0b013e3181d09ec9. |
| 29923111 | Background | Astorino TA, deRevere J, Anderson T, Kellogg E, Holstrom P, Ring S, Ghaseb N. Change in VO2max and time trial performance in response to high-intensity interval training prescribed using ventilatory threshold. Eur J Appl Physiol. 2018 Sep;118(9):1811-1820. doi: 10.1007/s00421-018-3910-3. Epub 2018 Jun 19. |
| 22977357 | Background | Ghosh AK. Anaerobic threshold: its concept and role in endurance sport. Malays J Med Sci. 2004 Jan;11(1):24-36. |
| 24930985 | Background | Fortington LV, Donaldson A, Lathlean T, Young WB, Gabbe BJ, Lloyd D, Finch CF. When 'just doing it' is not enough: assessing the fidelity of player performance of an injury prevention exercise program. J Sci Med Sport. 2015 May;18(3):272-7. doi: 10.1016/j.jsams.2014.05.001. Epub 2014 May 16. |
| 25970496 | Background | Tucker WJ, Sawyer BJ, Jarrett CL, Bhammar DM, Gaesser GA. Physiological Responses to High-Intensity Interval Exercise Differing in Interval Duration. J Strength Cond Res. 2015 Dec;29(12):3326-35. doi: 10.1519/JSC.0000000000001000. |
| 23832851 | Background | Buchheit M, Laursen PB. High-intensity interval training, solutions to the programming puzzle. Part II: anaerobic energy, neuromuscular load and practical applications. Sports Med. 2013 Oct;43(10):927-54. doi: 10.1007/s40279-013-0066-5. |
| 26028809 | Background | Ciolac EG, Mantuani SS, Neiva CM, Verardi C, Pessoa-Filho DM, Pimenta L. Rating of perceived exertion as a tool for prescribing and self regulating interval training: a pilot study. Biol Sport. 2015 Jun;32(2):103-8. doi: 10.5604/20831862.1134312. Epub 2015 Jan 15. |
| 19344864 | Background | Blair SN, Morris JN. Healthy hearts--and the universal benefits of being physically active: physical activity and health. Ann Epidemiol. 2009 Apr;19(4):253-6. doi: 10.1016/j.annepidem.2009.01.019. |
| 2795824 | Background | Blair SN, Kohl HW 3rd, Paffenbarger RS Jr, Clark DG, Cooper KH, Gibbons LW. Physical fitness and all-cause mortality. A prospective study of healthy men and women. JAMA. 1989 Nov 3;262(17):2395-401. doi: 10.1001/jama.262.17.2395. |
| 25566166 | Background | Hardcastle SJ, Ray H, Beale L, Hagger MS. Why sprint interval training is inappropriate for a largely sedentary population. Front Psychol. 2014 Dec 23;5:1505. doi: 10.3389/fpsyg.2014.01505. eCollection 2014. No abstract available. |
| 28119627 | Background | Weston M, Batterham AM, Tew GA, Kothmann E, Kerr K, Nawaz S, Yates D, Danjoux G. Patients Awaiting Surgical Repair for Large Abdominal Aortic Aneurysms Can Exercise at Moderate to Hard Intensities with a Low Risk of Adverse Events. Front Physiol. 2017 Jan 9;7:684. doi: 10.3389/fphys.2016.00684. eCollection 2016. |
| 30051418 | Background | Hurst C, Weston KL, Weston M. The effect of 12 weeks of combined upper- and lower-body high-intensity interval training on muscular and cardiorespiratory fitness in older adults. Aging Clin Exp Res. 2019 May;31(5):661-671. doi: 10.1007/s40520-018-1015-9. Epub 2018 Jul 26. |
| BG002 | Total | Total of all reporting groups |
| Participants |
|
| Age, Continuous | Mean | Standard Deviation | years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Race (NIH/OMB) | Count of Participants | Participants |
|
| Region of Enrollment | Count of Participants | Participants |
|
| Body mass index | Mean | Standard Deviation | kg.m-2 |
|
| Systolic blood pressure | Mean | Standard Deviation | mmHg |
|
| Diastolic blood pressure | Mean | Standard Deviation | mmHg |
|
| Resting heart rate | Mean | Standard Deviation | bpm |
|
| Respiratory exchange ratio at VO2max | Mean | Standard Deviation | unitless |
|
| Heart rate maximum | Mean | Standard Deviation | bpm |
|
| Maximum oxygen consumption/heart rate | Mean | Standard Deviation | ml.beat-1 |
|
| Peak power output | Mean | Standard Deviation | watts |
|
| OG001 | Circuit Training | The circuit training group completed a practical seven-station mixed modality exercise circuit (cycle ergometer, rower, treadmill, sit to stand, knee to elbow and leg kickback with bicep curl) at an intensity of 60-80%. Participants initially performed 20 minutes of CT with duration gradually increased to the desired 40 minutes as tolerated. Each station was occupied for three to six minutes depending on session duration with minimal rest in-between. Circuit training: The CT group completed a practical seven-station mixed modality exercise circuit (cycle ergometer, rower, treadmill, sit to stand, knee to elbow and leg kickback with bicep curl) at an intensity of 60-80% HRmax twice per week for eight weeks. Participants initially performed 20 minutes of CT with duration gradually increased to the desired 40 minutes as tolerated |
|
|
|
| Secondary | Oxygen Consumption at the Ventilatory Anaerobic Threshold | Oxygen consumption at the Ventilatory Anaerobic Threshold ml/kg/min. This measure will assess if individuals can exercise at higher intensities before lactate accumulation, thus becoming 'physiologically efficient | Posted | Mean | Standard Deviation | ml/kg/min | Baseline and 8 weeks |
|
|
|
|
| Other Pre-specified | Intervention Fidelity - Participants That Complied With the Exercise Protocols | To assess if the interventions were delivered as intended, percentage of participants that complied with the exercise protocols | To assess the validity of the exercise interventions, participant fidelity to the desired exercise intensity was determined using cut points using specific cut points. Fidelity was measured over the course of the 16 sessions. | Posted | Median | Inter-Quartile Range | Percentage | 8 weeks |
|
|
|
| Other Pre-specified | The Percentage of Individuals That Responsed to the Intervention | If participants had a postive increased in maximal oxygen consumption following the two interventions | A percentage of participants that increased maximal oxygen consumption | Posted | Number | Percentage | 8 weeks |
|
|
|
| 0 |
| 20 |
| 0 |
| 20 |
| 0 |
| 20 |
| EG001 | Circuit Training | The CT group completed a practical seven-station mixed modality exercise circuit (cycle ergometer, rower, treadmill, sit to stand, knee to elbow and leg kickback with bicep curl) at an intensity of 60-80%. Participants initially performed 20 minutes of CT with duration gradually increased to the desired 40 minutes as tolerated. Each station was occupied for three to six minutes depending on session duration with minimal rest in-between. Circuit training: The CT group completed a practical seven-station mixed modality exercise circuit (cycle ergometer, rower, treadmill, sit to stand, knee to elbow and leg kickback with bicep curl) at an intensity of 60-80% HRmax twice per week for eight weeks. Participants initially performed 20 minutes of CT with duration gradually increased to the desired 40 minutes as tolerated | 0 | 19 | 0 | 19 | 0 | 19 |
Not provided
Not provided
| D009142 |
| Musculoskeletal Physiological Phenomena |
| D055687 | Musculoskeletal and Neural Physiological Phenomena |