The aim of the C3S study is research an equivalence with longitudinal, radial and circumferential, global and segmental strain value, in left Ventricular in 2 and 3 dimension between two echograph General Electric Vivid 9 (GE Vingmed, Horton, Norway) et Philips Epiq 7.
Healthy volunteer will be inform about the study by email and press. They could join the clinical research team by email and phone to ask more questions about the study. Then the investigator, verify the eligibiliy of the volunteers and schedule an appointment for the visit of inclusion. During this visit, the patient's consent will be collected. One echocardiography will be complete on echograph General Electric Vivid 9 to collect the clinical data necessary for the study and to eliminate the presence of criteria of exclusions, the acquisition of the loops of ultrasound will be realized on both echographs by a first investigator. A second investigator will make the post-treatment of the ultrasound images on consoles ECHOPAC PC version 201, General Electric Medical System and Q Station version 3.5, Philips Healthcare in two different times, to obtain the values of the various strain.
Furthermore, an clinical exam, an ECG, a questionnary will be realized.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Comparison of two devices | Experimental | Patients receive clinical examination, electrocardiogramm and echocardiography. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Comparative standard echocardiography between two devices : Vivid 9 General Electric and Epiq 7 Philips | Device | Comparison of the various values of strain with the echograph General Electric and the electrograph Philips. |
| Measure | Description | Time Frame |
|---|---|---|
| Value of the longitudinal strain value, in left Ventricular in 2 and 3 dimension. | The acquisition of the ultrasound loops on both echographs is realized at the same time. The various values of strain are obtained after post-treatment of the ultrasound loops on ECHOPAC PC version 201 software for the echograph General Electric and the Q Station version 3.5 software for the echograph Phillips. The post-treatment on both software are made in two different times to avoid possible biases. | 1 year |
| Values of the radial strain value, in left Ventricular in 2 and 3 dimension. | The acquisition of the ultrasound loops on both echographs is realized at the same time. The various values of strain are obtained after post-treatment of the ultrasound loops on ECHOPAC PC version 201 software for the echograph General Electric and the Q Station version 3.5 software for the echograph Phillips. The post-treatment on both software are made in two different times to avoid possible biases. | 1 year |
| Values of the circumferential strain value, in left Ventricular in 2 and 3 dimension. | The acquisition of the ultrasound loops on both echographs is realized at the same time. The various values of strain are obtained after post-treatment of the ultrasound loops on ECHOPAC PC version 201 software for the echograph General Electric and the Q Station version 3.5 software for the echograph Phillips. The post-treatment on both software are made in two different times to avoid possible biases. | 1 year |
| Values of the global strain value, in left Ventricular in 2 and 3 | The acquisition of the ultrasound loops on both echographs is realized at the same time. The various values of strain are obtained after post-treatment of the ultrasound loops on ECHOPAC PC version 201 software for the echograph General Electric and the Q Station version 3.5 software for the echograph Phillips. The post-treatment on both software are made in two different times to avoid possible biases. |
| Measure | Description | Time Frame |
|---|---|---|
| Values of longitudinal global strain of the right ventricle between two echographs (General Electric and Philips). | The acquisition of the ultrasound loops on both echographs are realized at the same time. The various values of strain are obtained after post-treatment of the ultrasound loops on ECHOPAC PC version 201 software for the echograph General Electric and the Q Station version 3.5 software for the echograph Phillips. The post-treatment on both software are made in two different times to avoid possible biases. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Lise LACLAUTRE | Contact | 04 73 75 49 63 | drci@chu-clermontferrand.fr |
| Name | Affiliation | Role |
|---|---|---|
| Guillaume CLERFOND | University Hospital, Clermont-Ferrand | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| CHU de Clermont-Ferrand | Recruiting | Clermont-Ferrand | Auvergne | 63003 | France |
Not provided
All the healthy volunteers who consent to participate in the study, and who are eligible according to the protocol will have an clinical examination, an electrocardiogram and an echocardiography with two devices.
Not provided
Not provided
No masking description
Not provided
| 1 year |
| Values of the segmental strain value, in left Ventricular in 2 and 3 | The acquisition of the ultrasound loops on both echographs is realized at the same time. The various values of strain are obtained after post-treatment of the ultrasound loops on ECHOPAC PC version 201 software for the echograph General Electric and the Q Station version 3.5 software for the echograph Phillips. The post-treatment on both software are made in two different times to avoid possible biases. | 1 year |
| 1 year |
| Values of segmental 2D of the right ventricle between two echographs (General Electric and Philips). | The acquisition of the ultrasound loops on both echographs are realized at the same time. The various values of strain are obtained after post-treatment of the ultrasound loops on ECHOPAC PC version 201 software for the echograph General Electric and the Q Station version 3.5 software for the echograph Phillips. The post-treatment on both software are made in two different times to avoid possible biases. | 1 year |
| Values of strain 2D of the left atrium between two echographs (General Electric and Philips). | The acquisition of the ultrasound loops on both echographs are realized at the same time. The various values of strain are obtained after post-treatment of the ultrasound loops on ECHOPAC PC version 201 software for the echograph General Electric and the Q Station version 3.5 software for the echograph Phillips. The post-treatment on both software are made in two different times to avoid possible biases. | 1 year |